Data sheet PRO ECO 240W 48V 5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com You are looking for a reliable power supply with basic functions. With PROeco we can offer you low-cost switch-mode power supply units with high efficiency and system capability. Let's connect. In the series production of machines, in particular, switchmode power supply units with above-average performance values can deliver genuine competitive advantages. The low-cost PROeco series offers all the basic functions and delivers impressively high performance and flexibility. Our PROeco switch-mode power supply units feature a compact design, high efficiency and are extremely easy to maintain. Thanks to temperature protection, short-circuit and overload resistance they can be universally used in all applications. Wide-ranging safety functions and compatibility with our diode and capacitance modules, together with UPS components for setting up a redundant power supply, characterise solutions with PROeco. General ordering data Version Order No. Type GTIN (EAN) Qty. Power supply, switch-mode power supply unit, 48 V 1469590000 PRO ECO 240W 48V 5A 4050118275773 1 pc(s). Creation date February 16, 2021 5:28:40 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 1 Data sheet PRO ECO 240W 48V 5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Dimensions and weights Depth Height Net weight Width (inches) 100 mm 125 mm 1.014 g 2.362 inch Depth (inches) Height (inches) Width 3.937 inch 4.921 inch 60 mm -40 C...85 C Operating temperature -25 C...70 C Lead 7439-92-1 3000 m Temperatures Storage temperature Environmental Product Compliance REACH SVHC Rated data UL Operating altitude Input AC current consumption Connection system DC input voltage range Input frequency Inrush current Recommended back-up fuse 1.2 A @ 230 V AC / 2.4 A @ 115 V AC Screw connection 80...370 V DC (Derating @ 120 V DC) 47...63 Hz Max. 10 A 4 A / DI, safety fuse 10 A, Char. B, circuit breaker 3...4 A, Char. C, circuit breaker AC input voltage range DC current consumption Frequency range AC Input fuse (internal) Rated input voltage Surge protection 85...264 V AC (derating at 100 V AC) 1.2 A @ 370 V DC / 2.4 A @ 120 V DC 47...63 Hz Yes 100...240 V AC (widerange input) Varistor Output Capacitive load Nominal output current for Unom Output voltage Output voltage, max. Output voltage, note Parallel connection option Ramp-up time Residual ripple, breaking spikes unrestricted 5 A at 55 C 48 V 56 V (adjustable via potentiometer) yes, max. 5 100 ms < 100 mV ss @ 48 V DC, I Nenn Connection system Output power Output voltage Output voltage, min. Overload protection Protection against inverse voltage Rated output voltage Screw connection 240 W 42...56 V (adjustable via potentiometer) 42 V Yes Yes 48 V DC 1 % Creation date February 16, 2021 5:28:40 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 2 Data sheet PRO ECO 240W 48V 5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data General data AC failure bridging time @ Inom Earth leakage current, max. Indication Max. perm. air humidity (operational) Operating temperature Protection against over-heating Short-circuit protection > 20 ms @ 230 V AC / > 20 ms @ 115 V AC 3.5 mA Green LED (Uoutput > 21.6VDC), Yellow LED (loutput > 90% IRated typ. ), red LED (overload, overtemperature, short-circuit, Uoutput < 20.4VDC) 5 %...95 % RH -25 C...70 C Yes Yes Degree of efficiency Housing version MTBF 92 % Metal, corrosion resistant > 500,000 h in accordance with IEC 61709 (SN29500) on terminal rail TS 35 > 0.94 @ 230 V AC / > 0.99 @ 115 V AC Mounting position, installation notice Power factor (approx.) Protection against reverse voltages from the load 58...65 V DC EMC / shock / vibration Interference immunity test acc. to Noise emission in accordance with EN55032 Vibration resistance IEC 60068-2-6 EN 61000-4-2 (ESD), EN 61000-4-3 (RS), EN 61000-4-4 (burst), EN 61000-4-5 (surge), EN 61000-4-6 (conducted), EN61000-4-8 (Fields), EN61000-4-11 (Dips) Class B 1 g according to EN 50178 Limiting of mains voltage harmonic currents According to EN 61000-3-2 Shock resistance IEC 60068-2-27 Pollution severity 2 For use with electronic equipment Protective separation / protection against electrical shock Acc. to EN50178 / VDE0160 VDE0100-410 / acc. to DIN57100-410 15 g In all directions Insulation coordination Insulation voltage, input/output Protection class 3 kV I, with PE connection Electrical safety (applied standards) Electrical machine equipment Protection against dangerous shock currents Safety transformers for switch-mode power supplies Acc. to EN60204 Acc. to VDE0106-101 According to EN 61558-2-16 Connection data (input) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Wire connection cross section, flexible (input), max. 12 0.5 mm 0.5 mm 2.5 mm Conductor cross-section, AWG/kcmil , min. Conductor cross-section, rigid , max. Connection system 26 6 mm Screw connection Creation date February 16, 2021 5:28:40 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 3 Data sheet PRO ECO 240W 48V 5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Connection data (output) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , max. Conductor cross-section, rigid , max. Connection system 12 2.5 mm 6 mm Screw connection Conductor cross-section, AWG/kcmil , min. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals 26 0.5 mm 0.5 mm 6 (++,--,13,14) Signalling Contact load (NO contact) Relay on/off max. 30 V DC / 1 A Output voltage >21.6VDC/ <20.4VDC, overload Floating contact Yes E258476 Institute (cULus) CULUS EC002540 27-04-07-01 27-04-07-01 ETIM 7.0 ECLASS 9.1 ECLASS 11.0 EC002540 27-04-07-01 27-04-07-01 Approvals Certificate no. (cULus) Classifications ETIM 6.0 ECLASS 9.0 ECLASS 10.0 Approvals Approvals ROHS UL File Number Search Conform E258476 Downloads Approval/Certificate/Document of Conformity Engineering Data Engineering Data User Documentation Declaration of Conformity STEP EPLAN, WSCAD Operating instructions Creation date February 16, 2021 5:28:40 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 4 Data sheet PRO ECO 240W 48V 5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Drawings Electric symbol Derating curve Derating curve Derating curve Creation date February 16, 2021 5:28:40 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 5