Specifications liable to change without prior warning DPM 2 Issue 5 August/1997 M.C. Applies to DPM 2/1
PIN FUNCTIONS
ONBOARDLINKS
SAFETY
1. V- DPM2-negativepowersupplyconnection.
DPM2S-C2negativeconnection.
2. INLO Negativemeasuringinput. Analogueinputsmustbenocloserthan1Vtoeitherthepositiveornegativesupply.
3. INHI Positivemeasuringinput. ThenegativesupplyoftheDPM2S isgeneratedinternallyandmirrorsthepositivesupplyvoltage.
4. COM GroundforanaloguesectionofA/Dconverter, itisactivelyheldat2.8VbelowV+andmustnotbeallowedtosinkexcessivecurrent
(>100 A)by, forinstance, connectingtoahighervoltage.
5. REFLO Negativeinputforreferencevoltage.
6. REFHI Positiveinputforreferencevoltage(connectedviaLinkREFtointernalreference).
7. CAP-
8. CAP+
9. GND DPM2-noconnection.
DPM2S -0Vpowersupplyconnection.
10. V+ Positivepowersupplyconnection.
µ
Onboardlinkscanbemadewithasolderlinktoimplementfeatures.
DP1 MaketoturnonDP1(199.9).
DP2 MaketoturnonDP2(19.99).
DP3 MaketoturnonDP3(1.999).
REF Factorymade-ConnectsinternalreferencetoREFHI. Itshouldonlybecutifanexternalreferenceisused.
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the
measuringinputs doexceed60Vdc, thenfit scaling resistors externallytothe module. Theusermustensure thattheincorporation of theDPM
into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring,
ControlandLaboratoryUse).
VARIOUS OPERATING MODES
ON-BOARD LINK S: In order to quickly and easily change operating modes for
different applications the meter has several "on-board links". They are designed
to be easily op en ed (cu t) o r sh o rted (so lde red ).
Do not connect more than one meter to the same power supply if the meters cannot
use the same signal ground. Input filter should be as close as possible to the meter.
Taking any input beyond the power supply rails will damage th e meter.
Normally
SHORTED
Cut to
OPEN
Normally
OPEN
Solder to
SHORT
Measuring a floating voltage source
of 200mV full scale (DPM 2).
Measuring 4-20mA to read 0-999.
Supply MUST be isolated. (DPM 2)
Measuring a single ended input
referenced to supply (DPM 2S).
Split supply operation (DPM 2).
Measuring the ratio of two voltages.
Reading = 1000 V /V
50mV< V <200mV
V <2V . (DPM 2)
12
2
12
Measuring current. Supply MUST
be isolate d . (DPM 2)
Charge pump capacitor connections (DPM 2S only).
V+
V-
V+
10
4
2
5
3IN HI
IN LO
REF LO
COM
1
V-
+
-
±200mV
Check Link REF is SHORTED.
10nF
1M
V+
V+
10
2
4
5
3IN HI
IN LO
COM
REF LO
1V-
V-
Check Link REF is SHORTED.
10nF
220k
5k
6R2
1M
Iin
Iout
V+
V+
10
3
R4
5
IN HI
REF LO
IN LO
1V-
V-
R= 0.2
IFSR
V+
V+
10
6
2
5
3IN HI
IN LO
REF LO
REF HI
1
V-
V-
+
-
-
+
V1
V2
Check Link REF is OPEN.
Check Link REF is SHORTED.
10nF
1M
V+ +5V
V+
10
4
2
5
3IN HI
IN LO
REF LO
COM
CAP+
CAP-
9
V- 1
8
7
+
+
-
-
C2
1.5 Fµ
C1
1.5 Fµ
0V
GND
+
-
±200mV
Check Link REF is SHORTED.
10nF
1M
V+
V+
10
4
2
5
3IN HI
IN LO 14V max.
7V min.
1V
min.
REF LO
COM
1
V-
+
-
±200mV
Check Link REF is SHORTED.
10nF
1M
0V
P.O. Box 897, Windham, NH 03087
(603) 893-0886 (800) 821-0023 FAX (603) 898-6820