safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D182
AGo to the Engineering Guide
For in-depth information on
safety standards and use.
FGR-M1 Series
■ Specifications
ELECTRICAL
Operating Coil
Supply Power: 24 VDC
Current Rating: 15 mA 4 poles;
20.8 mA 6 poles
Power Usage: 360 mW 4 poles;
500 mW 6 poles
Switching Capability
Rated Load: 250 VAC 6 A; 30 VDC 6 A
Max. Switching Voltage: 250 VAC; 125 VDC
Max. Switching Current: 6 A
Max. Drop-Out Time*: 10 mS
MECHANICAL
Mechanical Life: 1 x 107 operations min.
Electrical Life: 100,000 operations min.
Mounting with Socket: 35 mm DIN rail or
2 screw holes for panel mounting
Wire Size: Screw terminals accept single 16
or 18 AWG stranded or solid wire
Socket Dimensions:
4-Pole: 72 x 22.5 x 60.5 mm (L x W x H)
6-Pole: 72 x 30 x 60.5 mm (L x W x H)
Weight:
4-Pole: approx. 2.5 oz. (71 g)
6-Pole: approx. 3.2 oz. (91 g)
Vibration: 10 to 55 Hz
ENVIRONMENTAL
Humidity: 35 to 85% RH
Operating Temp: -40 to 185°F (-40 to 85°C)
Approvals: EN61810-1, EN50205, UL 508,
CSA 22.2 No. 14
*The Drop-Out Time is the time it takes for the
N/O contacts to open after the coil voltage is
turned OFF.
Specifications are subject to change without
notice.
Conforms to EN61810-1 and EN50205
■ Description
The FGR-M1 Series relays have
contacts that are force-guided/me-
chanically-linked conforming to
EN61810-1 and EN50205. For
more information on force-guided
relays, see the article “Positively
Driven/Force-Guided Contacts”
on our website at www.sti.com/
pdf/820.pdf.
■ Power requirements — Coil
operating voltage of 24 VDC
■ Contacts are force-guided/me-
chanically-linked
■ Switching capabilities to 6 A
■ Full range of 4-pole and 6-pole
contact configurations
■ Easy installation — The FGR-
M1 Series may be mounted
on 35 mm DIN rail or surface
mounted with two screws
FGR-M1 Series
Force-Guided Relay Modules
C US
Rev. 9.07
safety light curtains
D
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D183
Socket with LED
Indicator light is
ON when power is
applied to socket.
FGR-M1 Series
*Please consult page DD-1 of our companion catalog for products found in Volume 2.
■ Ordering
Module with Socket (no LED)
Control Auxiliary
Model Type Contacts Contacts Part No.
FGRMS22-24 4-Pole 2 N/O 2 N/C 44532-2010
FGRMS31-24 4-Pole 3 N/O 1 N/C 44532-2020
FGRMS33-24 6-Pole 3 N/O 3 N/C 44532-2030
FGRMS42-24 6-Pole 4 N/O 2 N/C 44532-2040
FGRMS51-24 6-Pole 5 N/O 1 N/C 44532-2050
Module with Socket and LED Indicator
Control Auxiliary
Model Type Contacts Contacts Part No.
FGRMS22-24-LED 4-Pole 2 N/O 2 N/C 44532-2011
FGRMS31-24-LED 4-Pole 3 N/O 1 N/C 44532-2021
FGRMS33-24-LED 6-Pole 3 N/O 3 N/C 44532-2031
FGRMS42-24-LED 6-Pole 4 N/O 2 N/C 44532-2041
FGRMS51-24-LED 6-Pole 5 N/O 1 N/C 44532-2051
■ Socket Terminal Connections
4-Pole
44532-2010 24 VDC N/C N/C N/O N/O
Supply Auxiliary Auxiliary Control Control
44532-2020 24 VDC N/C N/O N/O N/O
Supply Auxiliary Control Control Control
6-Pole
44532-2030 24 VDC N/C N/C N/C N/O N/O N/O
Supply Auxiliary Auxiliary Auxiliary Control Control Control
44532-2040 24 VDC N/C N/C N/O N/O N/O N/O
Supply Auxiliary Auxiliary Control Control Control Control
44532-2050 24 VDC N/C N/O N/O N/O N/O N/O
Supply Auxiliary Control Control Control Control Control
+0 -1 11 12 21 22 33 34 43 44
+0 -1 11 12 23 24 33 34 43 44
+0 -1 11 12 21 22 31 32 43 44 53 54 63 64
+0 -1 11 12 21 22 33 34 43 44 53 54 63 64
+0 -1 11 12 23 24 33 34 43 44 53 54 63 64
Modules
Volume 2 Control Auxiliary
Model Model* Type Contacts Contacts Part No.
FGRM22-24 G7SA-2A2B 4-Pole 2 N/O 2 N/C 44532-1010
FGRM31-24 G7SA-3A1B 4-Pole 3 N/O 1 N/C 44532-1020
FGRM33-24 G7SA-3A3B 6-Pole 3 N/O 3 N/C 44532-1030
FGRM42-24 G7SA-4A2B 6-Pole 4 N/O 2 N/C 44532-1040
FGRM51-24 G7SA-5A1B 6-Pole 5 N/O 1 N/C 44532-1050
Sockets
Volume 2 Control Auxiliary
Model Model* Type Contacts Contacts Part No.
FGRS-4 P7SA-10F 4-Pole n/a n/a 44532-1704
FGRS-41 P7SA-10F-ND 4-Pole with LED n/a n/a 44532-1714
FGRS-6 P7SA-14F 6-Pole n/a n/a 44532-1706
FGRS-61 P7SA-14F-ND 6-Pole with LED n/a n/a 44532-1716