Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 1
The TE logo, Tyco Electronics and Raychem are trademarks. Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2009 Tyco Electronics Corporation. All rights reserved.
COMPONENT WIRES - 55A0111
NOTE: Nominal values are for information only.
Nominal values are not requirements.
SPECIFICATION CONTROL DRAWING 55A0121
TWO CONDUCTOR CABLE, UNSHIELDED, UNJACKETED, GENERAL PURPOSE, 600 VOLT 7-15-09 D
This specication sheet forms a part of the latest issue of Raychem Specication 55A.
TITLE Date Revision
CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
OUTSIDE DIAMETER
(inches) MAXIMUM
WEIGHT
(lbs/1000 ft.)
NOMINAL MAXIMUM
55A0121-30-* 30 .048 .052 1.3
55A0121-28-* 28 .054 .058 1.8
55A0121-26-* 26 .064 .068 2.8
55A0121-24-* 24 .074 .078 4.0
55A0121-22-* 22 .086 .090 5.7
55A0121-20-* 20 .100 .104 8.8
55A0121-18-* 18 .120 .124 13.3
55A0121-16-* 16 .136 .140 16.9
55A0121-14-* 14 .170 .176 26.5
55A0121-12-* 12 .206 .212 40.2
55A0121-10-* 10 .256 .268 64.9
55A0121-8-* 8 .376 .392 120.
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
INSULATION FLAWS:
Spark Test, 5.7 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
PART NUMBER:
The "*" in the part numbers above shall be replaced by color code designators with a slash
separating the component wire colors.
1/ Example: AWG 20, black and brown component wires:
55A0121-20-0/1
CABLE RATINGS AND ADDITIONAL REQUIREMENTS