OS-CM01E
COINlight
Data Sheet
Benefits
Small height
Ø
Wide viewing angle
Ø
Easy installation
Ø
Available in various colors
Ø
Applications
Border marker
Ø
In-ground mounted luminaires
Ø
Small signals
Ø
Walkways
Ø
Color Voltage
[V DC]* Power
[W]* Radiance
Angle [°]*
Wavelength [nm]
Color Temp [K]* Lum. Flux
[lm]*
Current
[A]*
Product
Number of
LEDs
Technical Operating Data
white 24 1,2 120 x=0,32; y=0,31 100,05OS-CM01E-W1 9
red 24 1,2 120 617 nm 240,05OS-CM01E-A1 9
yellow 24 1,2 120 587 nm 190,05OS-CM01E-Y1 9
green 24 1,2 120 525 nm 100,05OS-CM01E-T1 9
blue 24 1,2 120 470 nm 30,05OS-CM01E-B1 9
All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
*)
Technical Features
Modules optimized for use with OSRAM
OPTOTRONIC power supplies.
Ø
Dimmable by Pulse width modulation (PWM)
with the electronic controller OT DIM
Ø
Only parallel connection allowedØ
Diameter of the module: 33 mmØ
Connection with screw terminalsØ
Light emission vertical to the mounting surfaceØ
OS-CM01E - 02.12.03 Seite 1 von 4
Drawing
Operating Temperature
at Tc-Point [ °C ] * Storage Temperature
[ °C ] *
Product Voltage Range
[ V dc ] *
[ V dc ] *
Minimum and Maximum Ratings
OS-CM01E-W1 23 25 25...-30 75 -40 85... ...
OS-CM01E-A1 23 25 25...-30 85 -40 85... ...
OS-CM01E-Y1 23 25 25...-30 85 -40 85... ...
OS-CM01E-T1 23 25 25...-30 75 -40 85... ...
OS-CM01E-B1 23 25 25...-30 75 -40 85... ...
Exceeding maximum ratings for operation and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operation voltage will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module has to measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label (available e.g. at RS-Components). For exact location of the Tc-point see drawing below.
*)
OS-CM01E - 02.12.03 Seite 2 von 4
Safety Information
The LED module itself and all its components may not be mechanical stressed.
Ø
Assembly must not damage or destroy conducting paths on the circuit board.
Ø
The LED Module incorporates no protection against: Short circuits, Overload, Overheating. Therefore it is absolutely necessary to
operate the modules with a electronically stabilised power supply offering protection against the above mentioned safety risks.
For dimming applications attention should be paid to specific references in "OPTOTRONIC Technical Guide".
Parallel connection is highly recommended as safe electrical operation mode.
Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and demage the LED module.
Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.
Correct electrical polarity needs to be observed. Wrong polarity will result in no light emission.
Ø
Ø
Ø
OSRAM OPTOTRONIC power supplies are specifically designed with the necessary protection features for
safe operation.
When using other power supplies other than OPTOTRONIC the following basic safety features are required, in addition to any other
application specific concerns and local safety codes:
Short circuit protection
Ø
Overload protection
Overheat protection
Correct output voltage
Ø
Ø
Ø
Ø
Pay attention to ESD steps when mounting the module
Ø
The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion.
ØDamage by corrosion will not be honored as a materials defect claim. It is the user´s responsibility to provide suitable protection
against corrosive agents such as moisture and condensation and other harmful elements.
ØFor applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable
protection class. The module can be protected against condensation water by treatment with an appropriate circuit board grade
conformal coating. The conformal coating should have the following features:
- Optical transparency
- UV-resistance
- thermal expansion matching the thermal expansion of the module 15-30*10^-6 cm/cm/K
- low permeability of steam for all climatic conditions
- resistance against corrosive environment
The lacquer APL of the company Electrolube http://www.electrolube.com met the conditions for the COINlight in our tests.
OS-CM01E - 02.12.03 Seite 3 von 4
Assembly Information
ØRotation fixing by milled groove.
ØBetween bootom side and fixture housing should be an effective thermal contact.
Productgroup Productname EAN * S-Unit *
Ordering Guide
COINlight OS-CM01E-W1 4050300947914 25
COINlight OS-CM01E-A1 4050300857534 25
COINlight OS-CM01E-Y1 4050300947938 25
COINlight OS-CM01E-T1 4050300947952 25
COINlight OS-CM01E-B1 4050300947891 25
EAN: Ordering number per single module
S-Unit: Modules per shipping unit
*)
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Related and Further Information
The new dimension of light
Ø(in preparation)
OPTOTRONIC Technical Guide
Ø130 T08 E
OPTOTRONIC Data Sheets
Øwww.osram.com
Sales and Technical Support
OSRAM
Opto Semiconductors GmbH
Wernerwerkstrasse 2
D - 93049 Regensburg
Germany
www.osram-os.com
OSRAM GmbH
Hellabrunner Strasse 1
D - 81536 München
Germany
www.osram.com
+49 (0)89 6213-0
See web-page for local phone numbers