2011-05-27 1
201 1- 05- 2 7
Silicon NPN Phototransistor Arrays
NPN-Silizium-Fototransistor Zeilen
Version 1.0
BPX 80, BPX 82 ... BPX 89
Features: Besondere Merkmale:
Spectral range of sensitivity: 450 ... 1100 nm Spektraler Bereich der Fotoempfindlichkeit:
450 ... 1100 nm
Package: Miniature Array, Epoxy Gehäuse: Miniatur Array, Harz
Special: Multiple-digit array package Besonderheit: Mehrstellige Zeilenbauform
High linearity Hohe Linearität
Available in groups Gruppiert lieferbar
Applications Anwendungen
Miniature photointerrupters Miniatur Lichtschranken
Industrial electronics Industrieelektronik
For control and drive circuits Messen / Steuern / Regeln
2011-05-27 2
Version 1.0 BPX 80, BPX 82 ... BPX 89
Ordering Information
Bestellinformation
Maximum Ratings (TA = 25 °C)
Grenzwerte
Type: Photocurrent Ordering Code
Typ: Fotostrom Bestellnummer
λ = 950 nm, Ee = 0.5 mW/cm2, VCE = 5 V
IPCE [µA]
BPX 82 > 320 Q62702P0021
BPX 83 > 320 Q62702P0025
BPX 84 > 320 Q62702P0030
BPX 85 > 320 Q62702P0031
BPX 86 > 320 Q62702P0022
BPX 87 > 320 Q62702P0032
BPX 88 > 320 Q62702P0033
BPX 89 > 320 Q62702P0026
BPX 80 > 320 Q62702P0028
Note: Only one bin within one packing unit (variation less than 2:1)
Anm.: Nur eine Gruppe pro Verpackungseinheit (Streuung kleiner 2:1)
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
Operating and storage temperature range
Betriebs- und Lagertemperatur
Top; Tstg -40 ... 80 °C
Collector-emitter voltage
Kollektor-Emitter-Spannung
VCE 35 V
Collector current
Kollektorstrom
IC50 mA
Collector surge current
Kollektorspitzenstrom
(τ < 10 µs)
ICS 200 mA
Version 1.0 BPX 80, BPX 82 ... BPX 89
2011-05-27 3
Characteristics (TA = 25 °C)
Kennwerte
Emitter-collector voltage
Emitter-Kollektor-Spannung
VEC 7V
Total power dissipation
Verlustleistung
Ptot 90 mW
Thermal resistance for mounting on pcb
Wärmewiderstand für Montage auf PC-Board
RthJA 750 K/W
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
Wavelength of max. sensitivity
Wellenlänge der max. Fotoempfindlichkeit
λS max 850 nm
Spectral range of sensitivity
Spektraler Bereich der Fotoempfindlichkeit
λ10% 450 ... 1100 nm
Radiant sensitive area
Bestrahlungsempfindliche Fläche
A0.11mm
2
Dimensions of chip area
Abmessung der Chipfläche
L x W 0.55 x 0.55 mm x
mm
Half angle
Halbwinkel
ϕ± 18 °
Capacitance
Kapazität
(VCE = 0 V, f = 1 MHz, E = 0)
CCE 7.5 pF
Dark current
Dunkelstrom
(VCE = 20 V, E = 0)
ICE0 1 ( 50) nA
Rise and fall time
Anstiegs- und Abfallzeit
(IC = 1 mA, VCC = 5 V, RL = 1 k)
tr, tfs
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
2011-05-27 4
Version 1.0 BPX 80, BPX 82 ... BPX 89
Grouping (TA = 25 °C)
Gruppierung
Group Min Photocurrent Max
Photocurrent
Typ Photocurrent Rise and fall time
Gruppe Min Fotostrom Max Fotostrom Typ Fotostrom Anstiegs- und
Abfallzeit
Ee = 0.5 mW/cm2,
VCE = 5 V
Ee = 0.5 mW/cm2,
VCE = 5 V
EV = 1000 lx, Std.
Light A, VCE = 5 V
IC = 1 mA,
VCC = 5 V,
RL = 1 k
IPCE, min [µA] IPCE, max [µA] IPCE [µA] (typ) tr, tf [µs]
-A 320 630 1500 5.5
-B 400 800 1900 6
-C 500 2300 8
Group Collector-emitter saturation voltage
Gruppe Kollektor-Emitter Sättigungsspannung
IC = IPCEmin x 0.3, Ee = 0.5 mW/cm2
(typ) VCEsat [mV]
-A 150
-B 150
-C 150
Note: For delivery the components are marked -A, -B, -C. Due to differing yields, it is not possible to order a definite
group.
IPCEmin is the min. photocurrent of the specified group.
Anm.: Die gelieferten Bauelemente sind mit -A, -B, -C gekennzeichnet. Wegen Ausbeuteschwankungen ist jedoch
die Bestellung einer definierten Gruppe nicht möglich.
IPCEmin ist der minimale Fotostrom der jeweiligen Gruppe.
Version 1.0 BPX 80, BPX 82 ... BPX 89
2011-05-27 5
Relative Spectral Sensitivity
Relative spektrale Empfindlichkeit
Srel = f(λ)
Photocurrent
Fotostrom
IPCE = f(Ee), VCE = 5 V
Photocurrent
Fotostrom
IPCE / IPCE(25°C)= f(TA), VCE = 5 V
Dark Current
Dunkelstrom
ICEO = f(VCE), E = 0
400
0nm
%
OHF04048
20
40
60
80
100
λ
rel
S
10
30
50
70
500 600 700 800 900 1100
OHF04049
V
CE
0
10
101
10-1
10-2
CEO
I
nA
0V510 15 20 25 30 35
2011-05-27 6
Version 1.0 BPX 80, BPX 82 ... BPX 89
Dark Current
Dunkelstrom
ICEO = f(TA), E = 0
Collector-Emitter Capacitance
Kollektor-Emitter Kapazität
CCE = f(VCE), f = 1 MHz, E = 0
Total Power Dissipation
Verlustleistung
Ptot = f(TA)
nA
OHF04050
CEO
I
A
T
-2
10
-1
10
100
1
10
102
3
10
104
-25 0 25 50 75 100˚C
0
pF
OHF04051
CE
C
CE
V
10
-3
10
-2
10
-1
10
0
10
1
10
2
V
1
2
3
4
5
6
7
8
Version 1.0 BPX 80, BPX 82 ... BPX 89
2011-05-27 7
Directional Characteristics
Winkeldiagramm
Srel = f(ϕ)
2011-05-27 8
Version 1.0 BPX 80, BPX 82 ... BPX 89
Package Outline
Maßzeichnung
Dimensions in mm. / Maße in mm.
Version 1.0 BPX 80, BPX 82 ... BPX 89
2011-05-27 9
Transistors
Transistoren
Number of Transistors per Array Dimensions "A"
Transistoren pro Zeile Maße "A"
2 4.5 ... 4.9
3 7.0 ... 7.4
4 9.6 ... 10.0
5 12.1 ... 12.5
6 14.6 ... 16.0
7 17.2 ... 17.6
8 19.7 ... 20.1
9 22.3 ... 22.7
10 24.8 ... 25.2
Soldering Conditions
Lötbedingungen
TTW Soldering
Wellenlöten (TTW)
IEC-61760-1 TTW / IEC-61760-1 TTW
OHLY0598
0
0
50 100 150 200 250
50
100
150
200
250
300
T
t
C
s
235 C
10 s
C... 260
1. Welle
1. wave
2. Welle
2. wave
5 K/s 2 K/s
ca 200 K/s
CC... 130100
2 K/s Zwangskühlung
forced cooling
Normalkurve
standard curve
Grenzkurven
limit curves
2011-05-27 10
Version 1.0 BPX 80, BPX 82 ... BPX 89
Disclaimer Disclaimer
Attention please!
The information describes the type of component and
shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved.
Due to technical requirements components may contain
dangerous substances.
For information on the types in question please contact
our Sales Organization.
If printed or downloaded, please find the latest version in
the Internet.
Packing
Please use the recycling operators known to you. We
can also help you – get in touch with your nearest sales
office.
By agreement we will take packing material back, if it is
sorted. You must bear the costs of transport. For
packing material that is returned to us unsorted or which
we are not obliged to accept, we shall have to invoice
you for any costs incurred.
Components used in life-support devices or
systems must be expressly authorized for such
purpose!
Critical components* may only be used in life-support
devices** or systems with the express written approval
of OSRAM OS.
*) A critical component is a component used in a
life-support device or system whose failure can
reasonably be expected to cause the failure of that
life-support device or system, or to affect its safety or the
effectiveness of that device or system.
**) Life support devices or systems are intended (a) to be
implanted in the human body, or (b) to support and/or
maintain and sustain human life. If they fail, it is
reasonable to assume that the health and the life of the
user may be endangered.
Bitte beachten!
Lieferbedingungen und Änderungen im Design
vorbehalten. Aufgrund technischer Anforderungen
können die Bauteile Gefahrstoffe enthalten. Für weitere
Informationen zu gewünschten Bauteilen, wenden Sie
sich bitte an unseren Vertrieb. Falls Sie dieses
Datenblatt ausgedruckt oder heruntergeladen haben,
finden Sie die aktuellste Version im Internet.
Verpackung
Benutzen Sie bitte die Ihnen bekannten Recyclingwege.
Wenn diese nicht bekannt sein sollten, wenden Sie sich
bitte an das nächstgelegene Vertriebsbüro. Wir nehmen
das Verpackungsmaterial zurück, falls dies vereinbart
wurde und das Material sortiert ist. Sie tragen die
Transportkosten. Für Verpackungsmaterial, das
unsortiert an uns zurückgeschickt wird oder das wir nicht
annehmen müssen, stellen wir Ihnen die anfallenden
Kosten in Rechnung.
Bauteile, die in lebenserhaltenden Apparaten und
Systemen eingesetzt werden, müssen für diese
Zwecke ausdrücklich zugelassen sein!
Kritische Bauteile* dürfen in lebenserhaltenden
Apparaten und Systemen** nur dann eingesetzt
werden, wenn ein schriftliches Einverständnis von
OSRAM OS vorliegt.
*) Ein kritisches Bauteil ist ein Bauteil, das in
lebenserhaltenden Apparaten oder Systemen
eingesetzt wird und dessen Defekt voraussichtlich zu
einer Fehlfunktion dieses lebenserhaltenden Apparates
oder Systems führen wird oder die Sicherheit oder
Effektivität dieses Apparates oder Systems
beeinträchtigt.
**) Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper oder
(b) für die Lebenserhaltung bestimmt. Falls Sie
versagen, kann davon ausgegangen werden, dass die
Gesundheit und das Leben des Patienten in Gefahr ist.
Version 1.0 BPX 80, BPX 82 ... BPX 89
2011-05-27 11
Published by OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com © All Rights Reserved.