RCL e3
Long Side Termination Thick Film Chip Resistors Vishay
Document Number: 20046 For technical questions, contact: thickfilmchip@vishay.com www.vishay.com
Revision: 04-Mar-10 4
All tests are carried out in accordance with the following specifications:
•EN 60115-1, generic specification
•EN 140400, sectional specification
•EN 140401-802, detail specification
•IEC 60068-2 environmental test procedures
Packaging of components is done in paper or blister tapes according to IEC 60286-3
4.23 - Climatic sequence: -
± (1 % R + 0.05 Ω)± (2 % R + 0.1 Ω)
4.23.2 2 (Ba) Dry heat 125 °C; 16 h
4.23.3 30 (Db) Damp heat, cyclic 55 °C; ≥ 90 % RH;
24 h; 1 cycle
4.23.4 1 (Aa) Cold - 55 °C; 2 h
4.23.5 13 (M) Low air pressure 1 kPa; (25 ± 10) °C; 1 h
4.23.6 30 (Db) Damp heat, cyclic 55 °C; ≥ 90 % RH;
24 h; 5 cycles
4.23.7 - DC load U=
4.25.1 - Endurance
at 70 °C
U= ≤ Umax.;
1.5 h on; 0.5 h off;
70 °C; 1000 h ± (0.5 % R + 0.05 Ω)± (2 % R + 0.1 Ω)
70 °C; 8000 h ± (1 % R + 0.05 Ω)± (4 % R + 0.1 Ω)
4.18.2 58 (Td) Resistance to
soldering heat
Solder bath method
(260 ± 5) °C;
(10 ± 1) s
± (0.25 % R + 0.05 Ω) ± (0.5 % R + 0.05 Ω)
4.35 - Flamability,
needle flame test
IEC 60695-11-5;
10 s No burning after 30 s
4.24 78 (Cab) Damp heat,
steady state
(40 ± 2) °C;
(93 ± 3) % RH;
56 days
± (1 % R + 0.05 Ω)
4.25.3 -
Endurance at
upper category
temperature
155 °C, 1000 h ± (1 % R + 0.05 Ω)± (2 % R + 0.1 Ω)
4.40 -
Electrostatic
discharge
(Human Body Model)
IEC 61340-3-1*
3 pos. + 3 neg.
discharges;
ESD voltage: 1000 V
± (1 % R + 0.05 Ω)
4.29 45 (XA) Component solvent
resistance
Isopropyl alcohol;
50 °C; method 2 No visible damage
4.30 45 (XA) Solvent resistance
of marking
Isopropyl alcohol;
50 °C; method 1,
toothbrush
Marking legible,
no visible damage
4.22 6 (Fc) Vibration, endurance
by sweeping
f = 10 Hz to 2000 Hz;
x, y, z ≤ 1.5 mm;
A ≤ 200 m/s2;
10 sweeps per axis
± (0.25 % R + 0.05 Ω) ± (0.5 % R + 0.05 Ω)
4.37 - Periodic electric
overload
U=
≤ 2 x Umax.;
0.1 s on; 2.5 s off;
1000 cycles
± (1 % R + 0.05 Ω)
4.27 -
Single pulse high
voltage overload,
10 µs/700 µs
Û= 10 x
≤ 2 x Umax.;
10 pulses
± (1 % R + 0.05 Ω)
TEST PROCEDURES AND REQUIREMENTS
EN
60115-1
CLAUSE
IEC
60068-2
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (ΔR)
STABILITY CLASS 2 OR BETTER
Stability for product types:
RCL e3 1Ωto 1 MΩ
P70 x R
P70 x R
15 x P70 x R
P70 x R