Solid State Timers and Controllers 4210 Solid State AC Flasher The Model 4210 is an all solid state flasher intended for use in AC circuits only. Capable of flashing a load circuit up to one ampere at a fifty percent duty cycle. Output switch is ON for as long as it is OFF. Flash rates from 1 flash per minute up to 300 flashes per minute are available in five operating voltage ranges. The model 4210 has internal transient protection devices to assure reliable operation even when driving inductive load circuits such as relays or solenoids. Mechanical & Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.70 .76 .90 LOAD AC OPERATING VOLTAGE AC OPERATING VOLTAGE LOAD Mtg. Holes .156 Dia. 4 Places .20 2.25 2.65 Alternate Wiring .250 Quick Connect Terminals Timing Diagram . . . . . . . . . . . . . . . .27 How To Find The Flash Rate . . . . . . . . . . . . . . . Timing vs Timing Range The timingPeriod diagram shown below isResistance for an application that Output Always Turns ON First With Application of Operating Voltage requires the load circuit to be ON for 750 milliseconds and OFF for 750 milliseconds. (Remember - the ON and OFF times will essentially be equal due to the 50% duty cycle specification inherent in the model 4210) The voltage across the load circuit would look something this: ON Time = OFF Time ON .36 OFF ON Time = 0.75 Sec (750 milliseconds) Output OFF Time = 0.75 Sec (750 milliseconds) ON OFF Operating Voltage 50% ON V I S I T O U R W E B S I T E A T 50% OFF Flash Period = ON + OFF Time Flash Period = .750 + .750 = 1.5 Seconds Flash Rate in Flashes Per Minute (FPM) FPM = 60 / Flash Period FPM = 60 / 1.5 = 40 Flashes Per Minute : www.artisancontrols.com Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property Tel: 973-598-9400 * Fax: 973-598-9410 * Toll Free: 800-457-4950 Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA Solid State Timers and Controllers Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Voltage: Voltage Tolerances: Timing Mode: Fixed Flash Rate: Fixed Flash Duty Cycle: Flash Rate Duty Cycle Tolerance: Tolerances On Fixed Timing: Flash Rate Variation: Repeatability Of Flashing Period: Recycle Time: Output Rating: Output Switch Voltage Drop: Output Switch Leakage Current: Transient Protection: Dielectric: Operating Temperature: MTBF Rating: Construction: Agency Recognitions: Data Sheet Revision Date: AC only (12, 24, 48, 115, 230) 50/60 Hz. 15%. Flasher. Factory fixed at any rate from 1 to 300 flashes-per-minute (FPM) 50%. 10% (2% nominal). 2%, 5%, 10%, and 20% available. Less than 4% of set point over full temperature and voltage range. 2% at stabilized operating voltage temperature. Operating voltage must be removed for a minimum of 200 milliseconds to assure that timing and output circuits are reset. If it is not a requirement that the load circuit always be energized when operating voltage is reapplied, the operating voltage may be re-applied at any time. 10mA to 1A inductive with inrush current to 8A for 8 milliseconds. 3 volts AC maximum when load circuit is energized. 3 mA maximum when load circuit is de-energized. Output switch protected by silicon transient suppressors responding to transients within 1 x 10-12 seconds to a peak pulse power dissipation of 1500 watts, with transient surge currents to 200 amperes for durations up to 1/120 second at 25 C. Maximum transient voltage protection is 6000 volts as delivered through a source resistance of 30 ohms with a maximum duration of 8.3ms. 1500V rms all terminals to case. -20C to +85C 50,000 hrs minimum. Encapsulated module with .25 quick connect wiring terminals. UL File E47858, Appliance Controls - Component ATNZ2, Auxilliary Devices Component NKCR2. February 21, 2006 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Part Number - Operating Voltage - Flash Rate (FPM) 12 24 48 115 230 4210 - Specify Fixed Flash Rate Required From 1 to 300 Flashes Per Minute (FPM) Part Number Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4210-24-90FPM A model 4210 operating from 24V AC with a flash rate of 90 flashes-per-minute (FPM) The load circuit will be ON for 333mS and OFF for 33mS. 4210-115-60FPM A model 4210 operating from 115V AC with a flash rate of 60 flashes-per-minute (FPM) The load circuit will be ON for 500mS and OFF for 500 mS. V I S I T O U R W E B S I T E A T : www.artisancontrols.com Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property Tel: 973-598-9400 * Fax: 973-598-9410 * Toll Free: 800-457-4950 Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA