293
Power
Distribution
& Terminal
Blocks
Power Distribution &
Terminal Blocks
Section Contents Page
SSeelleeccttiioonn ttaabbllee ffoorr SSCCCCRR PPDDBBss && PPoowweerr
tteerrmmiinnaall bblloocckkss ................................................................229944
PPoowweerr ddiissttrriibbuuttiioonn bblloocckkss
Series PDBFS enclosed, with high SCCR . . . . . . . . . . . .295
Series PDB with high SCCR . . . . . . . . . . . . . . . . . . . . . 296
PPoowweerr tteerrmmiinnaall bblloocckkss
Series 163 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297-298
Series 11675 2- to 12-Pole quick-connect . . . . . . . . . . . 299
Series 11725 2- to 4-Pole quick-connect . . . . . . . . . . . . 299
Series 160, 162, 163 & 165 . . . . . . . . . . . . . . . . . . . . . . 299
SSeerriieess 116622,,116633 && 116655 ppoowweerr ssttuudd tteerrmmiinnaall bblloocckkss......330
000
SSeerriieess 116600,,116622,,116633 && 116655 ppoowweerr sspplliicceerr bblloocckkss........330000
SSeerriieess 1144000022 BBaarrrriieerr tteerrmmiinnaall bblloocckkss.................
...........330011
SSeerriieess 1144000044 DDeeaadd ffrroonntt tteerrmmiinnaall bblloocckk ........................330011
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
229944
Power Distribution & Terminal Blocks
Selection Table for SCCR Power Distribution Blocks and
Power Ter minal Blocks
Shor t-Circuit Current Rated Power Distribution
Blocks
Cooper Bussmann of fers three distinctly dif ferent styles of
short-circuit cur rent rated power distribution blocks (PDBs)
and power terminal blocks (PTBs) to ma tch different
application needs. The dif ferences are whether the power
distribution blocks are enclosed or not, and whether they are
UL1953 Listed PDBs or UL1059 Recognized PTBs, which
have different minimum spacing requirements. The table on
this page can assist in the selection of the right series for
your application requirements.
Why these are impor tant?
Assembly short-circuit cur rent ratings (SCCRs) are now
required in the 2008 NEC®and UL 508A Listed Industrial
Control Panels. Marking the SCCR on Industrial Control
Panels (NEC®409.110), Industrial Mac hiner y Electrical
Panels (NEC®607.3(A)), and HVAC equipment (NEC®
440.4(B)) is now required by the National Electrical Code.
PDBs or PTBs not marked with a SCCR, typically are the
weakest link and may limit an assembly to no more than 10kA
SCCR. The PDBFS and PDB Series have increased spacing
required where used in feeder circuits in equipment listed to
UL508A (UL1059 PTBs must be evaluated for proper spac-
ings). Also, for building wiring systems, the PDBFS Series
and PDB Series power distribution blocks can be used to
meet the new 2008 NEC®requirements in section 376.56(B)
for PDBs in wireways.
Industrial Industrial
Control Control HVAC Wireways
Description Catalog High Spacing** Panels Panels UL NEC®
Page UL
Enclosed
SCCR* 1” Air UL 508A UL 508A 1995 376.56(B)
2” Surface Branch Feeder (Requires
Circuit Circuit UL 1953)
Series PDBFS 295 UL 1953 Listed YesYes Yes Yes Yes Yes Yes
Yes
Series PDB 296 UL 1953 Listed No*** Yes Yes Yes Yes Yes w/optional
cover
Selection Table
IP20 finger-safe under specific conditions, see da tasheet 1149.
*When protected by proper fuse class with maximum ampere rating specified or less.
** See PDB Spacing Requirements for Equipment table below.
***Optional covers are available. Not IP20, but provide a safety benefit.
****No, except: Yes, if single pole units installed with proper spacings.
Spacing between Spacing between
live par ts of live par ts and
UL Standard opposite polarity grounded par ts
or enclosure
@600V
508A Feeder
Circuits
508A Branch
Circuits
1995 HVAC
Through air Over surface
@600V @600V
1˝2˝1˝
38˝12˝12˝
38˝12˝12˝
Note: Refer to Specific UL standards for complete spacing details.
PDB & PTB Minimum Spacing
Requirements for Equipment
Data Sheet: 1049
Series PDBFS
Series PDB
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 229955
Power
Distribution
& Terminal
Blocks
Power Distribution & Terminal Blocks
Series PDBFS of Power Distribution Blocks
Feature/Benefits
• Enclosed, safer
installation; IP20
finger-safe under specific
conditions
• High short-circuit current
ratings up to 200kA:
PDBs do not have to be
the weak link in achieving
high SCCR for an
industrial control panel
• Small footprint saves
panel space
• Listed to UL 1953 which has minimum spacing
requirements at 600V of at least 1” through air and 2” over
surface required for feeders in UL 508A Industrial Control
Panels
• For 2D CAD drawings visit www.cooperbussmann.com
Agency/Standards
• UL Listed 1953, Guide QPQS, File E256146
• CSA Certified, Class 6228-01, File 15364
• IEC 60947-7-1
• IEC 60529, IP20 (finger-safe) under specific wiring
conditions
Electrical
• 600Vac/dc (UL 1953), 690Vac/dc (IEC)
• IP20 finger-safe under specific conditions
• Short-circuit current ra tings up to 200kA, see table
• Ampacities up to 760 amps
• Cu wire range 14 AWG to 500 kcmil or 2.5 to 240 mm2
Mechanical
• DIN rail or panel mount; PDBFS330 & PDBFS504 panel
mount only
• Captive termina tion screws; screws do not get misplaced
• Wire ready: captive termina tion screws shipped backed out
to save time on conductor installations
• Sliding DIN rail latch for easy mounting
• Single pole, gang mountable for multiple pole applica tions
with interlocking dovetail accessory (optional)
• Flammability, UL 94V0
• Tin-plated Al connectors suita ble for Cu conductors
• Elongated hole for panel mounting; easier mounting with
grea ter flexibility in matching up with drilled panel holes
• Part 2A1279: Interlocking dovetail pin accessory
One pin interlocks two units, two pins to interlock three units
• DIN rail end anchors required to prevent damage to block
when torquing
Data Sheet: 1049
Ter minal Copper Conductor Capability Short-Circuit Cur rent Ra ting Data
Line Load Configuration Conductors Max Fuse Class & Amp**
Catalog
Number Openings per Pole Line Load J T RK1 RK5
(All Single Amps Wire Range Wire Range AWG or AWG or LPJ JJS LPS-RK FRS-R SCCR
Pole) Line Load kcmil kcmil JJN LPN-RK FRN-R
PDBFS204 175A 2/0 to 8 AWG 2/0 to 8 AWG 2/0 to 8 2/0 to 8 200 200 100 60 200kA
70 to 10 mm270 to 10 mm2
2/0 to 8 AWG 4 to 14 AWG 4 to 12 200 200 100 60 200kA
PDBFS220 175A 70 to 10 mm225 to 2.5 mm22/0 to 8 14 175 175 100 60 100kA
200 200 100 60 50kA
350kcmil to 6 AWG 350kcmil to 6 AWG
PDBFS303 310A 185 to 16 mm2185 to 16 mm2350 to 6 350 to 6 400 400 200 100 200kA
500kcmil to 6 AWG 2 to 14 AWG 2 to 6 400 400 200 100 200kA
PDBFS330 380A 240 to 16 mm235 to 2.5 mm2500 to 6 8 to 14 200 200 100 30 50kA
175 175 100 30 100kA
300kcmil to 4 AWG 4 to 14 AWG 300 4 to 8 600 600 400 200 200kA
PDBFS377 570A 150 to 12 mm225 to 2.5 mm2250 to 4 4 600 600 400 200 50kA
6 to 14 200 200 100 30 50kA
PDBFS500 620A 350kcmil to 4 AWG 350kcmil to 4 AWG 350 350 600 600 400 200 200kA
185 to 12 mm2185 to 12 mm2300 to 4 300 to 4 600 800* 600 200 100kA
500kcmil to 6 AWG 500kcmil to 6 AWG 500 500 600 800* 600 400 200kA
PDBFS504 760A 240 to 16 mm2240 to 16 mm2600 800* 600 600 100kA
400 to 6 400 to 6 600 600 400 200 100kA
Ampacities 75ºC per NEC®Table 310.16 and UL 508A Ta ble 28.1
*Class L 800A (KRP-C 800_SP) or less fuses suitable for this par ticular SCCR case.
** Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suitable for all SCCRs in this table.
Series PDBFS
Electrical
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
229966
Power Distribution & Terminal Blocks
Series PDB of Power Distribution Blocks
Feature/Benefits
• High short-circuit cur rent ratings up to 200kA. These
PDBs do not have to be the weak link in achieving high
SCCR for an industrial control panel
• Listed to UL 1953 which has minimum spacing
requirements at 600V of a t least 1” through air and 2” over
surface required for feeder in UL 508A Industrial Control
Panels
For 2D CAD drawings visit www.cooperbussmann.com
Agency/Standards
• UL Listed 1953, Guide QPQS, File E256146
Electrical
• 600Vac/dc (UL 1953)
• Short-circuit cur rent ratings up to 200kA, see table
• Wire range 14 AWG to 350 kcmil Cu
• Spacing between uninsulated opposite polarities or ground
meets UL 1953 which requires at least 1” through air and
2” over surface
• Ratings available with circuit breakers
Mechanical
• Panel mount
• Flammability, UL 94V0
• Tin-plated Al connectors suita ble for Cu conductors
Ter minal Copper Conductor Capability Short-Circuit Cur rent Ra ting Data
Line Load Configuration Conductors Max Fuse Class & Amp*
Catalog
Number Openings per Pole Line Load J T RK1 RK5
Amps Wire Range Wire Range AWG or AWG or LPJ JJS LPS-RK FRS-R SCCR
- Pole Line Load kcmil kcmil JJN LPN-RK FRN-R
PDB204-1
PDB204-3 175A 2/0 - 8 AWG 2/0 - 8 AWG 2/0 - 8 2/0 - 8 200 200 200 60 200kA
4 - 12 200 200 20060200kA
PDB220-1 175A 2/0 - 8 AWG 4 - 14 AWG 2/0 - 8 14 17517510060100kA
PDB220-3 2002001006050kA
PDB280-1 175A 2/0 - 8 AWG 1/4-20 X 3/4 STUD 2/0 - 8 Stud 200 200 100 60 200kA
PDB280-3
PDB321-1 4 -12 400 400 200100200kA
PDB321-2 175A 2/0 - 8 AWG 4 - 14 AWG 2/0 - 8 400400400100100kA
PDB321-3 14 17517510060100kA
PDB323-1 400 400 200100200kA
PDB323-3 310A 300kcmil - 4 AWG 4 - 12 AWG 300 - 4 4 - 8 400400400100100kA
10 - 12 17517510060100kA
PDB370-1 4 - 8 400 400 200100200kA
PDB370-3 310A 350kcmil - 4 AWG 4 - 14 AWG 350 - 4 10 - 14 400400400100100kA
17517510060100kA
PDB371-1 1/0 - 6 400 400 200100200kA
PDB371-3 310A 350kcmil - 4 AWG (6) 2 - 12 AWG 350 - 4 400400400100100kA
(3) 1/0-12 8 - 12 17517510060100kA
Ampacities 75ºC per NEC® Table 310.16 and UL508A Ta ble 28.1
* Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30_SP, KTK-R-30) or less are suitable for all these SCCR in this table.
Higher SCCR may be available, check data sheet 1149.
Series PDB
Data Sheet: 1049
Optional covers
Covers are ordered for each individual pole, i.e., three
1-pole covers for 3-pole block, see table A.
Except PDB321 blocks have one cover for 1, 2 or 3 pole
versions, see table B.
Table A Table B
Block Cover Block Cover
PDB2XX-(pole): CPB162-1 PDB321-1 CPDB-1
PDB3XX-(pole): CPDB-1 PDB321-2 CPDB-2
PDB321-3 CPDB-3
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 229977
Power
Distribution
& Terminal
Blocks
Power Distribution & Terminal Blocks
163 Series
Replaces Cooper Bussmann®
164 Series
Specifications
Description: Power terminal
block.
Dimensions: See Dimensions
illustrations.
Construction: Tin-plated
aluminum connectors.
Poles: 1- to 3-Poles, See
Catalog Numbers table on the
following page.
Wire Range: See Catalog
Numbers table on the following
page.
Ratings:
Volts: — 600Vac/dc
Amps: — See catalog Numbers table on the following page.
SCCR:— 10kA per UL 508A table SB4.1
Agency Information: CE, UL Recognized: Guide XCFR2,
UL E221592, General Industrial Class per UL1059, CSA
Certified: CSA LR15364
Flammability Rating: UL 94V0
Dimensions
Series 163 Power Ter minal Blocks
1-pole
1.96"
2-pole
3.58"
3-pole
5.20"
.31"
1.62"
3.25"
Mtg. hole 0.21 x 0.41,
c'bore 0.42 x 0.62 x 0.12 deep
3.32"
0.97"
4.00" 3.37"
Supplied with (4) #4 thread-cutting
screws assembled as shown
Textured surface for marking
CPDB-1 (single pole) 2.10"
CPDB-2 (two pole) 3.72"
CPDB-3 (three pole) 5.34"
4.14"
(See Following Page for Ratings)
Data Sheet: 1049
Series 163 Power Ter minal Blocks
Catalog Numbers
Basic
Catalog Wire Size Amps/
Numbers (Poles) Lineside (Poles) Loadside Pole Line/Load
16301* 250kcmil-6 AWG Cu Only 250kcmil-6 AWG Cu Only 255
16303 350kcmil-6 AWG Cu-Al 350kcmil-6 AWG Cu-Al 310
16306 500kcmil-6 AWG Cu-Al 500kcmil-6 AWG Cu-Al 380
16321 2/0-14 AWG CU, 2/0-8Al (6)4-14 AWG Cu, 4-8 AWG Al 175
16323 350kcmil-6 AWG Cu-Al (6)4-14 AWG Cu, 4-12 AWG Al 310
16325 (2)2/0-14 AWG Cu, 2/0-8 AWG Al (6)4-14 AWG Cu, 4-8 AWG Al 350
16330 500kcmil-6 AWG Cu-Al (6) 2-14 AWG Cu, 2-12 AWG Al 380
16332 350kcmil-6 AWG Cu-Al (3) 2-14 AWG Cu, 2-8 AWG Al 310
(2) 1/0-14 AWG Cu, 1/0-8 AWG Al
16335 500kcmil-6 AWG Cu-Al (3) 2-14 AWG Cu, 2-8 AWG Al 380
(2) 1/0-14 AWG Cu, 1/0-8 AWG Al
16370 350kcmil-6 AWG Cu-Al (12)4-14 AWG Cu, 4-12 AWG Al 310
16371 350kcmil-6 AWG Cu-Al (6) 2-14 AWG Cu, 2-8 AWG Al 310
(3) 1/0-14 AWG Cu, 1/0-8 AWG Al
16372 350kcmil-6 AWG Cu-Al (21) 10-14 AWG Cu, 10 AWG Al 310
16373 350kcmil-6 AWG Cu-Al (14) 10-14 AWG Cu, 10 AWG Al 310
(3) 1/0-14 AWG Cu-Al
16375 600kcmil-2 AWG Cu-Al (12)4-14 AWG Cu, 4-12 AWG Al 420
16376 600kcmil-2 AWG Cu-Al (6) 2-14 AWG Cu, 2-8 AWG Al 420
(3) 1/0-14 AWG Cu, 1/0-8 AWG Al
16377 (2)300kcmil-4 AWG Cu-Al (12)4-14 AWG Cu, 4-12 AWG Al 570
16378 500kcmil-6 AWG Cu-Al Stud Size (2) 1/4-20 x 1 380
16383 500kcmil-6 AWG Cu-Al Stud Size (1) 3/8-16 x 1 380
16390 38-16 x 118Stud Size 38-16 x 118Stud Size 250
16394 12-13 x 1116 Stud Size 12-13 x 1116 Stud Size 400
16395 38-16 x 1716 Stud Size (2) 14-20 x 916 Stud Size 310
*Copper connectors for use with copper wire only.
Ordering Information
163 Series blocks are available in 1-, 2- or 3-poles. To order: Basic Catalog Number + Number of poles.
Examples: 16301-1 = one-pole block
16301-3 = three-pole block
Data Sheet: 1049
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
298
Power Distribution & Terminal Blocks
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 299
Power
Distribution
& Terminal
Blocks
Power Distribution & Terminal Blocks
Power Ter minal Blocks
Series 11725
Specifications
Description: Screw
connection line side, (4) 0.250"
quick-connect load side power
terminal block.
Poles: 2-, 3- or 4-poles.
Wire Range: 2 – 14 AWG
Cu/8 AWG Al.
Ratings:
Volts: — 600Vac/dc
Amps: — Up to 70A
SCCR:— 10kA per UL 508A table SB4.1
Agency Information: CE, UL Guide XCFR2, E62622;
CSA LR15364.
Torque Rating: 45 lb-in max.
Catalog Numbers
CCaattaalloogg
NNuummbbeerrssPPoolleess
11725-2 2
11725-3 3
11725-4 4
Series 11675
Specifications
Description: Screw
connection line side, (3)
0.250" quick-connect
load side power
terminal block.
Poles:
2- to 12-poles.
Wire Range:
8 – 14 AWG Cu.
Ratings:
Volts: — 250Vac/dc
Amps: — Up to 40A
SCCR:— 10kA per UL 508A table SB4.1
Agency Information: CE, Guide XCFR2, UL E62622;
CSA LR15364.
Torque Rating: 9 lb-in max.
Catalog Numbers
CCaattaallooggCCaattaalloogg
NNuummbbeerrssPPoolleessNNuummbbeerrssPPoolleess
11675-2 2 11675-8 8
11675-3 3 11675-9 9
11675-4 4 11675-10 10
11675-5 5 11675-11 11
11675-6 6 11675-12 12
11675-7 7
Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163)
Series 160, 162, 163
& 165
Specifications
Description: Power
terminal blocks.
Construction: Molded black
thermoplastic.
Wire Range: See Catalog
Numbers table.
Poles:
Series 160: 2-, 3- or 4-poles
Series 162, 163 and 165: 1-, 2- or 3-poles
Ratings:
Volts: — 600Vac/dc
Amps: — Up to 1520A
SCCR:— 10kA per UL 508A table SB4.1
Agency Information: CE, Guide XCFR2, UL E221592
General Industrial Class per UL 1059; CSA Class 6228-01,
File 53787.
Flammability Rating: UL 94V0.
Catalog Numbers CCoonnnneeccttoorr
CCaattaallooggLLiinneeLLooaaddMMaatteerriiaall &&AAggeennccyy
NNuummbbeerrssCCoonnnneeccttiioonnCCoonnnneeccttiioonn AAmmppaacciittyyIInnffoorrmmaattiioonn
16021* 2/0-#14Cu, 2/0-#8Al (6)#4-#14Cu, #4-#8Al 175A UL/CSA
16023* 350kcmil-#6Cu/Al (6)#4-#14Cu, #4-#12Al 310A UL/CSA
16220 2/0-#14Cu, 2/0-#8Al (4)#4-#14Cu, #4-#8Al 175A UL/CSA
16321 2/0-#14Cu, 2/0-#8Al (6)#4-#14Cu, #4-#8Al 175A UL/CSA
16323 350kcmil-#6Cu/Al (6)#4-#14Cu, #4-#12Al 310A UL/CSA
16325 (2)2/0-#14Cu, 2/0-#8Al (6)#4-#14Cu, #4-#8Al 350A UL/CSA
16330 500kcmil-#6Cu/Al (6)#2-#14Cu, #2-#12Al 380A UL/CSA
16332 350kcmil-#6Cu/Al (3)#2-#14Cu, #2-#8Al 310A UL/CSA
(2)1/0-#14Cu, 1/0-#8Al
16335 500kcmil-#6Cu/Al (3)#2-#14Cu, #2-#8Al 380A UL/CSA
(2)1/0-#14Cu, 1/0-#8Al
16370 350kcmil-#6Cu/Al (12)#4-#14Cu, #4-#12Al 310A UL/CSA
16371 350kcmil-#6Cu/Al (6)#2-#14Cu, #2-#8Al 310A UL/CSA
(3)1/0-#14Cu, 1/0-#8Al
16372 350kcmil-#6Cu/Al (21)#10-#14Cu, #10Al 310A UL/CSA
16373 350kcmil-#6Cu/Al (3)1/0-#14Cu/Al 310A UL/CSA
(14)#10-#14Cu, #10Al
16375 600kcmil-#2Cu/Al (12)#4-#14Cu, #4-#12Al 420A UL/CSA
16376 600kcmil-#2Cu/Al (6)#2-#14Cu, #2-#8Al 420A UL/CSA
(3)1/0-#14Cu, 1/0-#8Al
16377 (2)300kcmil-#4Cu/Al (12)#4-#14Cu, #4-#12Al 570A UL/CSA
16400 (4)500kcmil-#6Cu/Al (22)#2-#14Cu/Al 1520A UL/CSA
16528 (2)600kcmil-#2Cu/Al (4)3/0-#6Cu/Al 840A UL/CSA
(4)#4-#14Cu/Al
16530 (2)500kcmil-#6Cu/Al (12)#4-#14Cu/Al 760A UL/CSA
16541 (1)500kcmil-#6Cu/Al (21)#6-#14Cu/Al 380A UL/CSA
*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)
have mounting holes within barriers. See Data Sheet for dimensional drawings.
How To Order
Catalog Number + # of Poles
Example: 16021 – 3 (complete part number)
Optional Covers:
160 Series: CPB160 - (pole)
162 Series: CPB162 - (pole)
163 Series: CPDB- (pole)
165 Series: CPDB165 (1 for each pole)
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
300
Power Distribution & Terminal Blocks
Power Ter minal Blocks: Stud & Splicer
Data Sheets: 1117 (Series 162, 165); 1148 (Series 163)
Series 162, 163 & 165
Specifications
Description: Power stud
terminal blocks.
Construction: Molded black
thermoplastic.
Poles: 1-, 2- or 3-poles.
Wire Range: See Catalog
Numbers table.
Ratings:
Volts: — 600Vac/dc
Amps: — Up to 760A
SCCR:— 10kA per UL 508A
table SB4.1
Agency Information: CE,
Guide XCFR2, UL E221592
General Industrial Class per UL
1059; CSA Class 6228-01, File 53787.
Flammability Rating:
UL 94V0.
Stud Block Catalog Numbers CCoonnnneeccttoorr
CCaattaallooggLLiinneeLLooaaddMMaatteerriiaall &&AAggeennccyy
NNuummbbeerrssCCoonnnneeccttiioonn ((PPoolleess))CCoonnnneeccttiioonn ((PPoolleess))AAmmppaacciittyyIInnffoorrmmaattiioonn
Connector to Stud
16280 2/0-#14Cu-Al 14-20 X 34Stud Al-175A UL
16281 2/0-#14Cu-Al 14-20 Tapped hole Al-175A UL
16378 500kcmil-#6Cu-Al (2)14-20 x 1 Stud Al-380A UL CSA
16383 500kcmil-#6Cu-Al (1)38-16 x 1 Stud Al-380A UL CSA
16582 (2)500kcmil-#6Cu-Al (2)38-16 x 158Stud Al-760A UL CSA
Stud to Stud
16290 14-20 x 34Stud 14-20 x 34Stud Cu-175A UL
16390 38-16 x 118Stud 38-16 x 118Stud Cu-250A UL CSA
16394 12-13 x 1116 Stud 12-13 x 1116 Stud Cu-400A UL CSA
16395 38-16 x 1716 Stud (2)14-20 x 916 Stud Cu-310A UL CSA
16591 38-16 x 1716 Stud (2)38-16 x 1716 Stud Cu-400A UL CSA
16593 12-13 X 1 Stud 12-13 X 1 Stud Cu-600A UL CSA
Nuts are not supplied with blocks
How To Order
Catalog Number + # of Poles
Example: 16000 – 3 (complete part number)
Optional Covers:
160 Series: CPB160 - (pole)
162 Series: CPB162 - (pole)
163 Series: CPDB - (pole)
165 Series: CPDB165 (1 for each pole) - new style
CPB165 - (pole) - old style
Series 160, 162,
163 & 165
Specifications
Description: Power
splicer
terminal blocks.
Construction: Molded
black thermoplastic.
Wire Range: See
Catalog Numbers table.
Poles: Series 160: 2-, 3- or 4-poles
Series 162, 163 and 165: 1-, 2- or 3-poles
Ratings:
Volts: — 600Vac/dc
Amps: — Up to 620A
SCCR:— 10kA per UL 508A table SB4.1
Agency Information: CE, Guide XCFR2, UL E221592
General Industrial Class per UL 1059; CSA Class 6228-01,
File 53787.
Flammability Rating: UL 94V0.
Catalog Numbers CCoonnnneeccttoorr
CCaattaallooggLLiinneeLLooaaddMMaatteerriiaall &&AAggeennccyy
NNuummbbeerrssCCoonnnneeccttiioonnCCoonnnneeccttiioonn AAmmppaacciittyyIInnffoorrmmaattiioonn
16000* 2/0-#8Cu/Al 2/0-#8Cu/Al Al-175A UL
16003* 250kcmil-#6Cu Only 250kcmil-#6Cu Only Cu-255A UL
16005* 350kcmil-#6Cu/Al 350kcmil-#6Cu/Al Al-310A UL
16200 #2-#14Cu, #2-#8Al #2-#14Cu, #2-#8Al Al-115A UL
16201 1/0-#14Cu Only 1/0-#14Cu Only Cu-150A UL
16204 2/0-#8Cu/Al 2/0-#8Cu/Al Al-175A UL
16301 250kcmil-#6Cu Only 250kcmil-#6Cu Only Cu-255A UL/CSA
16303 350kcmil-#6Cu/Al 350kcmil-#6Cu/Al Al-310A UL/CSA
16306 500kcmil-#6Cu/Al 500kcmil-#6Cu/Al Al-380A UL/CSA
16500 (2)350kcmil-#4Cu/Al (2)350kcmil-#4Cu/Al Al-620A UL/CSA
16504 (2)500kcmil-#6Cu/Al (2)500kcmil-#6Cu/Al Al-760A UL/CSA
*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)
have mounting holes within barriers. See Data Sheet for dimensional drawings.
How To Order
Catalog Number + # of Poles
Example: 16000 – 3 (complete part number)
Optional Covers:
160 Series: CPB160 - (pole)
162 Series: CPB162 - (pole)
163 Series: CPDB - (pole)
Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163)
For Short-circuit cur rent rated stud power distribution
blocks, go to the Series PDB and Series 162 & 163
with high SCCR.
For Short-circuit cur rent rated and/or finger-safe
splicer blocks, go to the Series PDBFS, Series PDB or
Series 162 & 163 with high SCCR.
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 301
Power
Distribution
& Terminal
Blocks
Power Distribution & Terminal Blocks
Series 14004
Specifications
Description: Dead
front terminal block.
Poles: 2 to 12 poles.
Wire Range:
4 – 14 AWG Cu/8
AWG Al.
Ratings:
Volts: — 600Vac/dc
Amps: — 90A
SCCR:— 10kA per UL 508A table SB4.1
Agency Information: CE, Guide XCFR2, UL E62622;
CSA LR15364.
Marking: Marking strip optional, consult factory.
Catalog Numbers
CCaattaallooggCCaattaalloogg
NNuummbbeerrssPPoolleessNNuummbbeerrssPPoolleess
14004-2 2 14004-8 8
14004-3 3 14004-9 9
14004-4 4 14004-10 10
14004-5 5 14004-11 11
14004-6 6 14004-12 12
14004-7 7
Series 14002
Specifications
Description: Barrier
terminal block.
Poles: 2- to 6-poles.
Wire Range: 2 – 14
AWG Cu/8 AWG Al.
Ratings:
Volts: — 600Vac/dc
Amps: — 115A
SCCR:— 10kA per
UL 508A table SB4.1
Agency Information: CE, Guide XCFR2, UL E62622;
CSA LR15364.
Torque Ratings*: 2-3, 50 lb-in; 4-6, 45 lb-in; 8, 40 lb-in;
10-14, 35 lb-in.
*Consult factory for torque ratings for CP and Q options.
Marking: Marking strip optional, consult factory.
Options For Load Side Connector
CP: Sems pressure plate, rated 60A, 600V
Q: Quick-Connect, rated 50A, 600V
To order options, enter letter code in front of Catalog
Number: i.e., CP14002-2.
Catalog Numbers
CCaattaallooggCCaattaalloogg
NNuummbbeerrssPPoolleessNNuummbbeerrssPPoolleess
14002-2 2 14002-5 5
14002-3 3 14002-6 6
14002-4 4
Power Ter minal Blocks: Barrier & Dead Front
302
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Eaton:
CP14002-2 CP14002-5