GU SOP 1 Form A (AQY21S) TESTING Miniature SOP4-pin type of 60V/350V/400V load voltage GU SOP 1 Form A (AQY21S) 4.4 .173 2.1 .083 4.3 .169 mm inch 1 4 2 3 RoHS compliant FEATURES TYPICAL APPLICATIONS 1. Controls low-level analog signals PhotoMOS feature extremely low closedcircuit offset voltage to enable control of low-level analog signals without distortion. 2. Small SOP4-Pin package The device comes in a miniature SOP4pin type measuring (W)4.3 x (L)4.4 x (H)2.1 mm (W).169 x (L).173 x (H).083 inch 3. Low-level off state leakage current of max. 1 A 4. Load voltage 60V, 350V and 400V types available * Telecommunication (PC, electronic notepad) * Measuring and testing equipment * Factory automation equipment * Security equipment * High speed inspection machines TYPES Output rating* AC/DC dual use Part No. Load voltage Load current 60V 500mA 350V 120mA 400V 100mA Package SOP4-pin Tube packing style Packing quantity Tape and reel packing style Picked from the Picked from the 1/2-pin side 3/4-pin side AQY212S AQY212SX AQY212SZ AQY210S AQY210SX AQY210SZ AQY214S AQY214SX AQY214SZ Tube Tape and reel 1 tube contains: 100 pcs. 1 batch contains: 2,000 pcs. 1,000 pcs. * Indicate the peak AC and DC values. Note: For space reasons, the three initial letters of the part number "AQY", the surface mount terminal indicator "S" and the packing style indicator "X" or "Z" are not marked on the device. (Ex. the label for product number AQY210SX is 210.) RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Item LED forward current LED reverse voltage Input Peak forward current Power dissipation Load voltage (peak AC) Continuous load current Output Peak load current Power dissipation Total power dissipation I/O isolation voltage Temperature limits Operating Storage ASCTB136E 201201-T Symbol IF VR IFP Pin VL IL Ipeak Pout PT Viso Topr Tstg Panasonic Corporation AQY212S AQY210S AQY214S 50 mA 5V 1A 75 mW 60 V 350 V 400 V 0.5 A 0.12 A 0.1 A 1.5 A 0.3 A 0.24 A 300 mW 350 mW 1,500 V AC -40C to +85C -40F to +185F -40C to +100C -40F to +212F Automation Controls Business Unit Remarks f = 100 Hz, Duty factor = 0.1% Peak AC, DC 100ms (1 shot), VL = DC Non-condensing at low temperatures industrial.panasonic.com/ac/e GU SOP 1 Form A (AQY21S) 2. Electrical characteristics (Ambient temperature: 25C 77F) Item Symbol Typical Maximum Minimum Typical Typical Maximum LED operate current Input LED turn off current LED dropout voltage AQY212S Maximum Transfer characteristics Maximum 25 2.5 25 35 0.65 ms 0.23 ms Ton Maximum Typical Maximum 0.21 ms 2 ms 0.08 ms 0.5 ms 0.5 ms Remarks IL = Max. IL = Max. IF = 50 mA IF = 5 mA IL = Max. Within 1 s on time IF = 0 mA VL = Max. 1 A ILeak Typical Turn off time* 17 VF Ron Turn on time* 0.83 IFoff Typical Off state leakage current AQY214S IFon On resistance Output AQY210S 0.9 mA 3 mA 0.4 mA 0.85 mA 1.25 V (1.14 V at IF = 5 mA) 1.5 V Toff IF = 5 mA IL = Max. 0.04 ms IF = 5 mA IL = Max. 0.2 ms I/O capacitance Maximum Ciso 1.5 pF Initial I/O isolation resistance Minimum Riso 1,000 M f = 1 MHz VB = 0 V 500 V DC *Turn on/Turn off time Input 90% Output 10% Toff Ton RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Input LED current Symbol IF Recommended value Unit 5 mA For Dimensions. For Schematic and Wiring Diagrams. For Cautions for Use. These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. For more information. REFERENCE DATA 1. Load current vs. ambient temperature characteristics 2. On resistance vs. ambient temperature characteristics 3. Turn on time vs. ambient temperature characteristics Allowable ambient temperature: -40C to +85C -40F to +185F Measured portion: between terminals 3 and 4; LED current: 5 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC) LED current: 5 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC) 700 3.0 50 AQY212S 400 300 40 30 AQY210S 20 2.5 Turn on time, ms 500 AQY214S On resistance, Load current, mA 600 2.0 1.5 AQY212S 1.0 200 AQY210S 100 0 -40 -20 10 AQY214S 0 20 AQY214S AQY210S 0.5 AQY212S 40 60 8085 100 Ambient temperature, C Panasonic Corporation 0 -40 -20 0 20 40 60 80 85 Ambient temperature, C Automation Controls Business Unit 0 -40 -20 industrial.panasonic.com/ac/e 0 20 40 60 8085 Ambient temperature, C ASCTB136E 201201-T GU SOP 1 Form A (AQY21S) 4. Turn off time vs. ambient temperature characteristics 5. LED operate current vs. ambient temperature characteristics 6. LED turn off current vs. ambient temperature characteristics LED current: 5 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC) Sample: All types; Load voltage: Max. (DC); Continuous load current: Max. (DC) Sample: All types; Load voltage: Max. (DC); Continuous load current: Max. (DC) LED operate current, mA Turn off time, ms 0.4 0.3 0.2 AQY212S 5 LED turn off current, mA 5 0.5 4 3 2 1 0.1 AQY214S, AQY210S 0 -40 -20 0 20 40 60 0 8085 4 3 2 1 -40 -20 Ambient temperature, C 0 20 40 60 0 8085 -40 -20 Ambient temperature, C 0 20 40 60 80 85 Ambient temperature, C 7. LED dropout voltage vs. ambient temperature characteristics 8-(1). Current vs. voltage characteristics of output at MOS portion 8-(2). Current vs. voltage characteristics of output at MOS portion Sample: All types; LED current: 5 to 50 mA Measured portion: between terminals 3 and 4; Ambient temperature: 25C 77F Measured portion: between terminals 3 and 4; Ambient temperature: 25C 77F Current, A LED dropout voltage, V 1.4 1.3 -1 1.2 -0.5 1.1 1.0 0.4 AQY212S 0.2 0 50mA 30mA 20mA 10mA 5mA Current, mA 0.6 1.5 AQY210S AQY214S 100 80 60 40 20 -5 -4 -3 -2 -1 0 0.5 Voltage, V 1 2 3 4 5 -20 Voltage, V -40 1 -0.2 -60 -0.4 -80 -100 0 -40 -20 -0.6 0 20 40 60 8085 Ambient temperature, C 9. Off state leakage current vs. load voltage characteristics 10. Turn on time vs. LED forward current characteristics 11. Turn off time vs. LED forward current characteristics Measured portion: between terminals 3 and 4; Ambient temperature: 25C 77F Measured portion: between terminals 3 and 4; Load voltage: Max. (DC); Continuous load current: Max. (DC); Ambient temperature: 25C 77F Measured portion: between terminals 3 and 4; Load voltage: Max. (DC); Continuous load current: Max. (DC); Ambient temperature: 25C 77F 0.12 1.0 10-7 AQY210S AQY212S 10 -9 10 -11 AQY214S 0.8 0.6 40 60 80 100 0 0 10 20 30 40 50 AQY214S AQY210S 0 60 LED forward current, mA Load voltage, V 0.06 0.02 AQY214S, AQY210S 20 0.08 0.04 0.4 0.2 10-13 0 AQY212S 0.10 AQY212S Turn off time, ms 10-5 Turn on time, ms Off state leakage current, A 1.2 10-3 0 10 20 30 40 50 LED forward current, mA 12. Output capacitance vs. applied voltage characteristics Measured portion: between terminals 3 and 4; Frequency: 1 MHz; Ambient temperature: 25C 77F Output capacitance, pF 200 150 100 AQY212S AQY214S, AQY210S 50 0 0 10 20 30 40 50 Applied voltage, V ASCTB136E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e 60