Tension/Compression Canister Load Cell
Model 3156
FEATURES
• Englishthreads(metriccongurationavailable:3156-133)
• Resistfatiguefailure
• Minimizebendingstrains
• Dualbridgesavailableonallmodels
• Multi-beamstructuredesign
• Enhancedresistancetosideloadsandbendingmoments
DESCRIPTION
TheModel3156fatigue-resistantloadcellsareextremely
resistanttoextraneousbendingandsideloadingforces.The
structurevirtuallyeliminatesbendingstrainsatthestraingage,
minimizingtheprimarycauseofloadcellfailure.Dualbridge
optionavailableforfeedbackcontrolandredundancy.
2Honeywell•SensingandControl
Model 3156
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Loadrange1100K,200K,500K,750KN
Non-linearity ±0.2%ofratedoutput
Hysteresis ±0.2%ofratedoutput
Repeatability ±0.05%ofratedoutput
Output@ratedcapacity ±2mV/V(nominal)
Operation Tension/compression
Resolution Innite
Standardcalibration Tension(+)andcompression(-)
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature,operating -54°Cto93°C[-65°Fto200°F]
Temperature,compensated 21°Cto77°C[70°Fto170°F]
Temperatureeffect,zero ±0.003%ofratedoutput/°F
Temperatureeffect,output ±0.003%ofreading/°F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype Foil
Excitation(maximum) 30VdcorVacRMS
Insulationresistance >5000mOhm@50Vdc
Bridgeresistance
(tolerance)
350ohm
Numberofbridges 1or2
Zerobalance ±1.0%
Electricaltermination MS-3102E-14S-5P
MECHANICAL SPECIFICATIONS
Characteristic Measure
Staticoverloadcapacity 150%ofnominalcapacity
Material Carbonsteel
Fatiguelife(0tofullfatigue
load)
100x106cycles
Fatiguelife(fullfatigueten-
siontocompression)
50x106cycles
Naturalfrequency Seetable
WIRING CODES
Wire
Red (+)excitation
Black (-)excitation
Green (+)output
White (-)output
TYPICAL SYSTEM DIAGRAM
Honeywell
In-Line Amplifier
Output Input
Serial Number
Power Supply
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
MODEL 3156
(Used with unamplified units only)
UV
UV-10
UBP
U3W
U2W
DV-05
DA-05
DV10
In-Line Amplifiers
Amplifier
Universal In-Line Amplifiers
DIN rail Mount In-Line Amplifiers
Output
+/-5 VDC
+/-10 VDC
0 +/-5 VDC
4-20mA (3 wire)
4-20mA (2 wire)
0 +/- 5 VDC (3 wire)
4-20mA (3 wire)
0 +/- 10 VDC (3 wire)
2003.1 lb.
L1 L2 L3 L4
UP
DOWN
VALUE CLEAR CHAN TARE
ENTER
SETUP
EXIT
SC500 SC1000 SC2000
SC2001 SC3004
GM NK HH
7541 7558 7561-PSD
Display Units
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
Mating Connectors & Cables
OR
064-LW13621 Mating connector
7200-76-XX* Mating connector and six conductor cable
(unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
(unamplified sensor without sense leads)
7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
for connection to 7541
Honeywell•SensingandControl3
Tension/Compression Canister Load Cell
NATURAL FREQUENCY
Nominal load limit
capacity Fz
Static extraneous load limits
lb N Static
overload
capacity (%
of nominal
capacity)
Fatigue
capacity (%
of nominal
capacity)
Shear FX or
FY (lb)
Bending MX
or MY (lb-in)
Torque MZ
(lb-in)
Deection
at nominal
load limit
(in)
Ringing
frequency
(Hz)
25K 100K 150 100 2K 68K 10K 0.003 2100
50K 200K 150 100 6K 130K 20K 0.003 3000
100K 500K 150 100 10K 220K 85K 0.003 4200
150K 750K 150 100 20K 220K 85K 0.003 4800
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in]
3156 17,78[7] 13,97[5.50] 8,89[3.50] 5,41[2.13] 12,07[4.75] 2,87[1.13] 13,84[5.45]
H cm [in] J cm [in] K cm [in] L cm [in] M cm [in] N cm [in] P cm [in] *R cm [in]
9,12[3.59] 8,89[3.50] 0,79[0.31] 0,95[0.38] 5,08[2] 3,18[1.25] M20x2.5[3/4-10] M52x2[2-12]
*3156-133•PandRaremetricthreadmeasures
*3156standard•PandRareEnglishthreadmeasures
MOUNTING DIMENSIONS
P THD. N DEEP 6 HOLES
EQUALLY SPACED ON J DIA.
BOTH ENDS
RECEP.
MS-3102E-14S-5P
H
R THD.
M DEEP
BOTH ENDS
SPANNER WRENCH HOLES
L DIA. K DEEP
3 HOLES EQUALLY SPACED
BOTH ENDS
G
C
A
E
F
D
DIA.
B
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008645-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 3156 Tension/Compression Canister Load Cell
NOTES
1.ThisunitcalibratedtoImperial(non-Metric)units.
Warranty. Honeywellwarrantsgoodsofitsmanufactureas
beingfreeofdefectivematerialsandfaultyworkmanship.
Honeywell’sstandardproductwarrantyappliesunlessagreed
tootherwisebyHoneywellinwriting;pleaserefertoyour
orderacknowledgementorconsultyourlocalsalesofcefor
specicwarrantydetails.Ifwarrantedgoodsarereturnedto
Honeywellduringtheperiodofcoverage,Honeywellwillrepair
orreplace,atitsoption,withoutchargethoseitemsitnds
defective.The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
Whileweprovideapplicationassistancepersonally,throughour
literatureandtheHoneywellwebsite,itisuptothecustomerto
determinethesuitabilityoftheproductintheapplication.
Specicationsmaychangewithoutnotice.Theinformationwe
supplyisbelievedtobeaccurateandreliableasofthisprinting.
However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visit
www.honeywell.com/sensingorcall+1-815-235-6847
Emailinquiriestoinfo.sc@honeywell.com
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stopdevicesorinanyotherapplicationwherefailureof
theproductcouldresultinpersonalinjury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisfor
referenceonly.DONOTUSEthisdocumentasproduct
installationinformation.
•Completeinstallation,operationandmaintenance
informationisprovidedintheinstructionssuppliedwith
eachproduct.
Failure to comply with these instructions could result in