OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue C 11/2010
Page 2 of 4
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
High Voltage Isolator
OPI1268
Electrical Characteristics (TA = 0° C to 70° C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
Input Diode
VF Forward Voltage - 1.3 1.6 V IF = 20 mA
IR Reverse Current - 0.1 100 µA VR = 2.0 V
Output IC (VCC = 4.5 V to 5.25 V) (See OPL550 for additional information—for reference only.)
IOH High Level Output Current - 0.20 10 µA IF = 0.0 mA, VOH = 18.0 V, Vcc = 5.25 V
VOL Low Level Output Voltage - 0.44 0.55 V IF = 10.0 mA, IOL = 8.0 mA, Vcc = 4.5 V
ICCH High Level Supply Current - 4.2 7 mA IF = 0, Vcc = 5.25V
ICCL Low Level Supply Current - 6.7 10 IF = 10.0 mA, Vcc = 5.25 V
Coupled Characteristics (VCC = 5 V)
CIO Coupling Capacitance - - 2 pF Input and output leads shorted.
tPLH Propagation Delay to Low Output Level - - 200 ns See Figure 1
tPHL Propagation Delay to High Output Level - - 100
IISO Isolation Leakage Current - - 1 µA VISO = @ 7kV RMS
( input and output leads shorted)
IF+ LED Positive Going Threshold Current 0.8 1.7 5.0 mA VCC = 5V, IOL = 8.0mA
Absolute Maximum Ratings (TA = 25o C unless otherwise noted)
Storage Temperature -40° C to +100° C
Operating Temperature -40° C to +100° C
Input-to-Output Isolation Voltage(1)(2) 16 KVDC
Lead Soldering Temperature (1/16” (1.6 mm) from case for 5 seconds with soldering iron)(3) 260° C
Input Diode
Continuous Forward Current 30 mA
Peak Forward current (1 µs pulse width, 300 pps) 3.0 A
Reverse Voltage 3.0 V
Power Dissipation(1) 100 mW
Maximum Supply Voltage 7 V
Power Dissipation(1) 40 mW
Output IC
Maximum Output Voltage 18 V
Maximum Output Current 25 mA
Notes:
(1) Derate linearly 1.33 W/°C above 25°C
(2) UL registered under E58730.
(3) RMA flux is recommended. The duration can be extended to 10 seconds maximum when flow soldering.