Additional Resources: Product Page | 3D Model | PCB Footprint date 12/10/2020 page 1 of 10 SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY FEATURES * * * * * * wide input range (85 ~ 305 VAC) wide operating temperature range (-40 to +85 C) IEC/EN/UL 62368 certified designed to meet 60335 household safety certifications over voltage, over current, short circuit protections flexible implementations to power a wide array of applications MODEL output voltage output current output power ripple and noise1 efficiency2 (Vdc) typ (A) max (W) max (mVp-p) typ (%) PBO-10-3 3.3 2.0 6.6 150 70 PBO-10-5 5 2.0 10.0 150 76 PBO-10-9 9 1.1 10.0 150 78 PBO-10-12 12 0.83 10.0 150 80 PBO-10-15 15 0.67 10.0 150 81 PBO-10-24 24 0.42 10.0 150 82 Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with a 1 F ceramic and 10 F electrolytyic capacitor on the output. 2. At 230 Vac input. 3. All specifications are measured at Ta=25C, humidity <75%, 115 or 230 Vac input voltage, and rated output load unless otherwise specified. PART NUMBER KEY PBO-10 - XX - X Base Number Output Voltage cui.com Orientation: "blank" = vertical B = right-angle Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 2 of 10 INPUT parameter conditions/description min voltage frequency current at 115 Vac at 230 Vac inrush current at 115 Vac at 230 Vac max units 85 100 typ 305 430 Vac Vdc 47 63 Hz 0.3 0.15 A A 15 30 A A OUTPUT parameter conditions/description min max units capacitive load 3.3 Vdc output models 5 Vdc output models 9 Vdc output models 12 Vdc output models 15 Vdc output models 24 Vdc output models 1,500 1,500 1,000 680 470 330 F F F F F F initial set point accuracy from 0~100% load 3.3 Vdc output models all other models 3 2 % % line regulation at rated load 0.5 1 % load regulation from 0~100% load 1 1.5 % temperature coefficient typ 0.02 %/C PROTECTIONS parameter conditions/description min over voltage protection output voltage clamp or hiccup 3.3 & 5 Vdc output models 9 Vdc output models 12 & 15 Vdc output models 24 Vdc output models over current protection auto recovery short circuit protection continuous, auto recovery, hiccup typ max units 9 15 25 35 Vdc Vdc Vdc Vdc 110 % SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output, 1 min, <5mA safety approvals certified to 62368: IEC, EN, UL designed to meet 60335: IEC, EN safety class class II conducted emissions CISPR32/EN55032 Class A (recommended circuit 1,4) CISPR32/EN55032 Class B (recommended circuit 2,3) radiated emissions CISPR32/EN55032 Class A (recommended circuit 1,4) CISPR32/EN55032 Class B (recommended circuit 2,3) ESD IEC/EN61000-4-2, 6 kV, perf. Criteria B radiated immunity IEC/EN61000-4-3, 10V/m, perf. Criteria A EFT/burst IEC/EN61000-4-4, 2 kV (recommended circuit 1,2), perf. Criteria B IEC/EN61000-4-4, 4 kV (recommended circuit 3,4), perf. Criteria B surge IEC/EN61000-4-5, line to line 1kV (recommended circuit 1,2), perf. Criteria B IEC/EN61000-4-5, line to line 2kV (recommended circuit 3,4), perf. Criteria B IEC/EN61000-4-5, line to line 4kV (recommended circuit 4), perf. Criteria B conducted immunity IEC/EN61000-4-6, 10 Vr.m.s, perf. Criteria A voltage dips & interruptions IEC/EN61000-4-11 0%, 70%, perf. Criteria B MTBF RoHS min typ 3,000 as per MIL-HDBK-217 at C 300,000 yes cui.com max units Vac hours Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 3 of 10 ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curves -40 85 C -40 105 C 95 % storage temperature storage humidity non-condensing DERATING CURVES EFFICIENCY CURVES cui.com typ Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 4 of 10 MECHANICAL parameter conditions/description dimensions 44.50 x 24.00 x 15.00 (1.751 x 0.944 x 0.590 inches) min weight typ Vertical Orientation units: mm[inch] pin section tolerance: 0.10[0.004] tolerance: 0.50[0.020] PIN CONNECTIONS PIN Function 1 AC (N) 3 AC (L) 5 +V(CAP) 7 -V(CAP) 14 -Vo 16 +Vo cui.com units mm 11 MECHANICAL DRAWING max g Additional Resources: Product Page | CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY Right-angle Orientation units: mm[inch] tolerance: 0.50[0.020] pin section tolerance: 0.10[0.004] PIN CONNECTIONS Function 1 AC (N) 3 AC (L) 5 +V(CAP) 7 -V(CAP) 14 -Vo 16 +Vo | PCB Footprint date 12/10/2020 page 5 of 10 MECHANICAL DRAWING (CONTINUED) PIN 3D Model cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 6 of 10 APPLICATION DESIGN REFERENCE PBO-10 series additional circuits design reference Immunity design circuits for reference Class III Emissions design circuits for reference Class IV Class A Class B PBO-10 Series additional component selection guide Part no. FUSE (required) C1 (required) PBO-10-3 PBO-10-12 L1 (required) 470F/16V (solid-state capacitor) PBO-10-5 PBO-10-9 C2 (required) 1A/300V 22F/450V 470F/35V PBO-10-24 220F/35V CY1 (required) C4 TVS2 SMBJ7.0A 150F/35V 270F/16V (solid-state capacitor) PBO-10-15 C31 (required) 4.7F (max 60m) 100F/35V SMBJ7.0A 0.1F/50V SMBJ12A 1.0nF/400Vac SMBJ20A SMBJ20A 47F/35V SMBJ30A Note: 1. Recommended to use a high frequency, low ESR, electrolytic capacitor with at least 20% margin on voltage rating. 2. A suppressor diode (TVS) is recommended to protect the downstream application in case of converter failure and should be rated for a minimum of 1.2 times the converter's output voltage. PBO-10 Series Environmental and EMC selection guide Recommended circuit Application environment 1 Basic application Environment temperature Emissions Immunity None -40 ~ 85C Class A Class III Indoor civil Smart home / Home appliances (2 Y-caps) -25 ~ 55C Intelligent building / Intelligent agriculture Class B Class III Indoor general Indoor industrial Manufacturing workshop -25 ~ 55C Class B Class IV Oudoor general ITS / Video monitoring / Charging point / Communication / Securitiy and protection -40 ~ 85C Class A Class IV Outdoor harsh On-line power meter Communication base station -40 ~ 85C Class A Surge: line to gnd 4KV EFT: Class IV 2 3 4 Input voltage range Typical industry 85 ~ 305 Vac cui.com Class IV Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 7 of 10 EMC RECOMMENDED CIRCUIT Circuit 1 Table 1 Application environment Ambient temperature range Immunity Class Emissions Class Basic application -40C ~ 85C Class III Class A Component Recommended value R1 12/3W LDM 4.7mH Note: R1 must be a wire-wound resistor; do not use a chip or carbon film resistor. Circuit 2 Table 2 Application environment Ambient temperature range Immunity Class Emissions Class Indoor civil / general -25C ~ 55C Class III Class B Component Recommended value R1 12/3W CY1 (CY2) 1.0nF/400Vac LCM 3.5 mH LDM 0.33 mH CX 0.1F/310Vac FUSE (required) 1A/300V, slow-blow Note: 1. For Smart Home and Home Appliance applications two Y-capacitors are required in series (2.2 nF/400 Vac each) to meet 60335 household safety rquirements. 2. R1 must be a wire-wound resistor; do not use a chip or carbon film resistor. cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 8 of 10 EMC RECOMMENDED CIRCUIT (CONTINUED) Circuit 3 Table 3 Application environment Ambient temperature range Immunity Class Emissions Class Indoor industrial -25C ~ 55C Class IV Class B Component Recommended value MOV S14K350 C1 22uF/450V CY1 2.2nF/400Vac CX 0.1F/310Vac LCM 3.5mH LDM 0.33mH R1 12/3W FUSE (required) 2A/300V, slow-blow Note: R1 must be a wire-wound resistor; do not use a chip or carbon film resistor. cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 9 of 10 EMC RECOMMENDED CIRCUIT (CONTINUED) Circuit 4 Table 4 Application environment Ambient temperature range Immunity Class Emissions Class Outdoor general -40C ~ 85C Class IV Class A Component Recommended value MOV S14K350 C1 22uF/450V LDM 4.7mH R1 12/3W FUSE (required) 2A/300V, slow-blow Note: R1 must be a wire-wound resistor; do not use a chip or carbon film resistor. Table 5 Application environment Ambient temperature range Immunity Class Emissions Class Outdoor harsh -40C ~ 85C Class IV surge: line to ground 4kV EFT: Class IV Class A Component Recommended value MOV S20K350 C1 33uF/450V (surge protection priority) LDM 4.7mH R1 33/5W FUSE (required) 6.3A/300V, slow-blow Note: R1 must be a wire-wound resistor; do not use a chip or carbon film resistor. cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc SERIES: PBO-10 DESCRIPTION: AC-DC POWER SUPPLY date 12/10/2020 page 10 of 10 REVISION HISTORY rev. 1.0 description date initial release 12/10/2020 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.