Tension/Compression In-Line Load Cell
Model 3124
DESCRIPTION
The small-diameter, cost-efficient load cells are designed to
be used in applications that require an ability to mount in an
existing system with restricted working area. They are commonly
used in fluid power transfer systems. Their low cost and ease of
mounting allow simultaneous testing of multi-element systems.
They may be directly attached to the piston rod of a hydraulic
cylinder. Side-mounted cable connectors allow cable assemblies
to be supported without affecting movement of the cell during
tension or compression loading.
FEATURES
• 5000lbto25000lbrange
• 0.25%non-linearity
• 0.15%hysteresis
• Adaptsdirectlytohydrauliccylinder
• Smalldiameterallowsmountinginrestrictedareas
• Lowdeection
2Honeywell•SensingandControl
Model 3124
RANGE CODES
Range Code Available ranges
DR 5000lb
DV 10000lb
EJ 15000lb
EL 20000lb
EM 25000lb
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Loadrange15000,10000,15000,20000,25000lb
Non-linearity ±0.25%ofratedoutput
Hysteresis ±0.15%ofratedoutput
Repeatability ±0.05%ofratedoutput
Output @ rated capacity ±2mV/V(nominal)
Operation Tension/compression
Resolution Infinite
Standard calibration Tension(+)andcompression(-)
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54°Cto93°C[-65°Fto200°F]
Temperature, compensated 21°Cto77°C[70°Fto170°F]
Temperature effect, zero ±0.002%ofratedoutput/°F
Temperature effect, output ±0.002%ofreading/°F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Foil
Excitation(maximum) 20VdcorVacRMS
Insulation resistance >5000mOhm@50Vdc
Bridge resistance
(tolerance)
350ohm
Number of bridges 1or2
Zero balance ±1.0%
MECHANICAL SPECIFICATIONS
Characteristic Measure
Static overload capacity 150%ofnominalcapacity
Material Carbonsteel
Natural frequency See table
TYPICAL SYSTEM DIAGRAM
Honeywell
In-Line Amplifier
Output Input
Serial Number
Power Supply
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
MODEL 3124
(Used with unamplified units only)
UV
UV-10
UBP
U3W
U2W
DV-05
DA-05
DV10
In-Line Amplifiers
Amplifier
Universal In-Line Amplifiers
DIN rail Mount In-Line Amplifiers
Output
+/-5 VDC
+/-10 VDC
0 +/-5 VDC
4-20mA (3 wire)
4-20mA (2 wire)
0 +/- 5 VDC (3 wire)
4-20mA (3 wire)
0 +/- 10 VDC (3 wire)
2003.1 lb.
L1 L2 L3 L4
UP
DOWN
VALUE CLEAR CHAN TARE
ENTER
SETUP
EXIT
SC500 SC1000 SC2000
SC2001 SC3004
GM NK HH
7541 7558 7561-PSD
Display Units
Mating Connectors & Cables
OR
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
064-LW13621 Mating connector
7200-76-XX* Mating connector and six conductor cable
(unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
(unamplified sensor without sense leads)
7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
for connection to 7541
Honeywell•SensingandControl3
Tension/Compression In-Line Load Cell
NATURAL FREQUENCY
Nominal load limit
capacity Fz
Static extraneous load limits
lb N Static
overload
capacity (%
of nominal
capacity)
Fatigue
capacity (%
of nominal
capacity)
Shear FX or
FY (lb)
Bending MX
or MY (lb-in)
Torque MZ
(lb-in)
Deection
at nominal
load limit
(in)
Ringing
frequency
(Hz)
5K 20K 150 n/a 250 750 15000 0.005 4600
10K 50K 150 n/a 250 700 1100 0.005 6400
15K 75K 150 n/a 450 1300 2100 0.005 7700
20K 100K 150 n/a 650 2000 3000 0.005 8800
25K 125K 150 n/a 950 2700 4500 0.005 9600
Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in]
3124 11,43[4.50] 2,54[1.0] 0,97[0.38] 2,06[0.81] 3,81[1.50] 3,51[1.38] 6,20[2.44] 4,37[1.72]
MOUNTING DIMENSIONS
1.0-14 THD.
B DEEP
E DIA.
F DIA.
G
D
A
C
B
H
E
HEX
RECEP.
MS-3102E-14S-5P
1.0-14 THD.
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008661-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 3124 Tension/Compression In-Line Load Cell
NOTES
1.ThisunitcalibratedtoImperial(non-Metric)units.
Warranty. Honeywellwarrantsgoodsofitsmanufactureas
being free of defective materials and faulty workmanship.
Honeywell’sstandardproductwarrantyappliesunlessagreed
tootherwisebyHoneywellinwriting;pleaserefertoyour
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywellduringtheperiodofcoverage,Honeywellwillrepair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literatureandtheHoneywellwebsite,itisuptothecustomerto
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visit
www.honeywell.com/sensingorcall+1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stopdevicesorinanyotherapplicationwherefailureof
theproductcouldresultinpersonalinjury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisfor
referenceonly.DONOTUSEthisdocumentasproduct
installationinformation.
•Completeinstallation,operationandmaintenance
informationisprovidedintheinstructionssuppliedwith
eachproduct.
Failure to comply with these instructions could result in
death or serious injury.