CHEMTRONICS TDS # CP400 Technical Data Sheet Chempad Presaturated Wipe PRODUCT DESCRIPTION Chempad Presaturated Wipes are general purpose, lint-free cleaning wipes. They are excellent for general purpose cleaning of computers, office and laboratory equipment. These highly effective cleaning wipes are ideal for cleaning sensitive surfaces, fiber optic connectors, electronics components, touch keypads, keyboards, instrument housings, and magnetic tape heads. Chempad quickly and safely removes handling soils, dirt and oxides from PCB's, mechanical / electrical assemblies and other electronic equipment. Chempad is especially effective in removing ink and permanent marker. Chempad Presaturated Wipes contain ultrapure isopropyl alcohol (91% IPA / 9% Pure Water) on an ultra-soft, lint free synthetic felt. Plastic Safe Dries Fast Leaves No Residue Nonabrasive Upper Ozone Safe; CFC/HCFC Free TYPICAL APPLICATIONS Chempad cleans and degreases: Keyboards and Touch pads Cables Fiber Optic Connectors Cabinets and Housings TYPICAL PRODUCT DATA AND PHYSICAL PROPERTIES Specific Gravity 0.81 Solubility in Water Soluble Evaporation Rate <1 (Ether = 1) Appearance Clear, Colorless Liquid Flash Point (TCC) 61o F Percent Volatile 100% Shelf life 2 years COMPATIBILITY Chempad Presaturated Wipes are generally compatible with most plastics, glass and metals. Compatibility must be checked with all antiglare coatings. As with any chemical product, component compatibility must be determined on a non-critical area prior to use. ENVIRONMENTAL IMPACT DATA Material Aluminum Buna-N CPVC Epoxy Neoprene Noryl Phenolic Cross-Linked PE Polycarbonate Polypropylene Polystyrene PVC Teflon Tygon Viton Compatibility Excellent Good Excellent Excellent Good Excellent Excellent Good Poor Good Poor Fair Excellent Good Excellent USAGE INSTRUCTIONS For industrial use only. ENVIRONMENTAL IMPACT DATA CFC HCFC CL Solv. 0.0% 0.0% 0.0% VOC HFC ODP 91% 0.0% 0.0 CFC, HCFC, CL. SOLV., VOC, and HFC numbers shown are the content by weight. Ozone depletion potential (ODP) is determined in accordance with the Montreal Protocol and U.S. Clean Air Act of 1990. The ODP of this product is zero. NOTE: This information is believed to be accurate. It is intended for professional end users having the skills to evaluate and use the data properly. CHEMTRONICS does not guarantee the accuracy of the data and assumes no liability in connection with damages incurred while using it. Read MSDS carefully prior to use. ChempadTM Presaturated Wipes: Remove wipe from packet and lightly wipe away any dust or contaminants from surfaces. Allow surface to dry completely before use. AVAILABILITY CP400 50 Premoistened Wipes TECHNICAL & APPLICATION ASSISTANCE Chemtronics provides a technical hotline to answer your technical and application related questions. Call toll free at: 1-800-TECH401 (1-800-832-4401). CHEMTRONICS 8125 COBB CENTER DRIVE KENNESAW, GA 30152 1-770-424-4888 REV. A (05/04) Chemtronics is a registered trademark of Chemtronics. All rights reserved. Chempad is a trademark of Chemtronics. All rights reserved. DISTRIBUTED BY: