TABLE III. Irradiation test connections. 1/ 2/
Case Ground V = 5 V ± 0.25 V
DD
V 9 1,2,3,4,5,6,7,8,10,11,
12,13,14,15,16,17,18
1/ Each pin except V and GND connections will have a
DD
series resistor of 47k
S
±5% for irradiation testing.
2/ Irradiation samples only assembled in case outline V.
3.9 Verification and review for device class M. For device class M, DESC, DESC's agent, and the acquiring activity retain the
option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made
available onshore at the option of the reviewer.
3.10 Microcircuit group assignment for device class M. Device class M devices covered by this drawing shall be in
microcircuit group number 41 (see MIL-PRF-38535, appendix A).
4. QUALITY ASSURANCE PROVISIONS
4.1 Sampling and inspection. For device class M, sampling and inspection procedures shall be in accordance with
MIL-STD-883 (see 3.1 herein). For device classes Q and V, sampling and inspection procedures shall be in accordance with
MIL-PRF-38535, or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan
shall not effect the form, fit, or function as described herein.
4.2 Screening. For device class M, screening shall be in accordance with method 5004 of MIL-STD-883, and shall be
conducted on all devices prior to quality conformance inspection. For device classes Q and V, screening shall be in accordance
with MIL-PRF-38535, and shall be conducted on all devices prior to qualification and technology conformance inspection.
4.2.1 Additional criteria for device class M.
a. Delete the sequence specified as initial (preburn-in) electrical parameters through interim (postburn-in)
electrical parameters of method 5004 and substitute lines 1 through 6 of table IIA herein.
b. For device class M, the test circuit shall be maintained by the manufacturer under document revision level control and
shall be made available to the preparing or acquiring activity upon request. For device class M, the test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1015.
(1) Dynamic burn-in for device class M (method 1015 of MIL-STD-883, test condition D; for circuit, see 4.2.1b herein).
c. Interim and final electrical parameters shall be as specified in table IIA herein.
4.2.2 Additional criteria for device classes Q and V.
a. The burn-in test duration, test condition, and test temperature or approved alternatives shall be as specified in
the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be
maintained under document revision level control of the device manufacturer's Technology Review Board
(TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity
upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in
accordance with the intent specified in test method 1015 or as modified in the device manufacturer's QM plan.
b. Interim and final electrical test parameters shall be as specified in table IIA herein.
c. Additional screening for device class V beyond the requirements of device class Q shall be as specified in appendix B
of MIL-PRF-38535 or as modified in the device manufacturers Quality Management (QM) plan.
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for groups
A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
4.4 Conformance inspection. Quality conformance inspection for device class M shall be in accordance with MIL-STD-883
(see 3.1 herein) and as specified herein. Inspections to be performed for device class M shall be those specified in method
5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections (see 4.4.1 through 4.4.4). Technology conformance
inspection for classes Q and V shall be in accordance with MIL-PRF-38535 or as specified in the QM plan, including groups A,
B, C, D, and E inspections and as specified herein except where option 2 of MIL-PRF-38535 permits alternate in-line control
testing.