3D7010 MONOLITHIC 10-TAP FIXED DELAY LINE (SERIES 3D7010) FEATURES * * * * * * * * * * * PACKAGES All-silicon, low-power CMOS technology* TTL/CMOS compatible inputs and outputs Vapor phase, IR and wave solderable Auto-insertable (DIP package) Low ground bounce noise Leading- and trailing-edge accuracy Delay range: 8 through 500ns Delay tolerance: 5% or 2ns Temperature stability: 3% typical (0C-70C) Vdd stability: 2% typical (4.75V-5.25V) Minimum input pulse width: 20% of total delay IN 1 14 VDD N/C 2 13 O1 O2 3 12 O3 O4 4 11 O5 O6 5 10 O7 O8 6 9 O9 GND 7 8 O10 IN N/C N/C O2 O4 O6 O8 GND 3D7010 DIP 3D7010G Gull-Wing 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 VDD N/C O1 O3 O5 O7 O9 O10 3D7010S SOL (300 Mil) For mechanical dimensions, click here. FUNCTIONAL DESCRIPTION PIN DESCRIPTIONS The 3D7010 10-Tap Delay Line product family consists of fixed-delay CMOS integrated circuits. Each package contains a single delay line, tapped and buffered at 10 points spaced uniformly in time. Tap-to-tap (incremental) delay values can range from 8ns through 50ns. The input is reproduced at the outputs without inversion, shifted in time as per the user-specified dash number. The 3D7010 is TTL- and CMOScompatible, capable of driving ten 74LS-type loads, and features both rising- and falling-edge accuracy. IN O1 O2 O3 O4 O5 O6 O7 O8 O9 O10 VDD GND The all-CMOS 3D7010 integrated circuit has been designed as a reliable, economic alternative to hybrid TTL fixed delay lines. It is offered in a standard 14-pin auto-insertable DIP and a space saving surface mount 16-pin SOIC. Delay Line Input Tap 1 Output (10%) Tap 2 Output (20%) Tap 3 Output (30%) Tap 4 Output (40%) Tap 5 Output (50%) Tap 6 Output (60%) Tap 7 Output (70%) Tap 8 Output (80%) Tap 9 Output (90%) Tap 10 Output (100%) +5 Volts Ground TABLE 1: PART NUMBER SPECIFICATIONS PART NUMBER DIP-14 SOIC-16 3D7010 3D7010S 3D7010G -80 -80 -90 -90 -100 -100 -150 -150 -200 -200 -250 -250 -300 -300 -400 -400 -500 -500 NOTE: TOLERANCES TOTAL TAP-TO-TAP DELAY DELAY (ns) (ns) 80 4.0 8.0 1.5 90 4.5 9.0 1.7 100 5.0 10.0 2.0 150 7.5 15.0 2.0 200 10.0 20.0 2.5 250 12.5 25.0 2.5 300 15.0 30.0 3.0 400 20.0 40.0 4.0 500 25.0 50.0 5.0 Max Operating Frequency 4.17 MHz 3.70 MHz 3.33 MHz 2.22 MHz 1.67 MHz 1.33 MHz 1.11 MHz 0.83 MHz 0.67 MHz INPUT RESTRICTIONS Absolute Max Min Operating Oper. Freq. Pulse Width 31.2 MHz 27.8 MHz 25.0 MHz 16.7 MHz 12.5 MHz 10.0 MHz 8.33 MHz 6.25 MHz 5.00 MHz 120.0 ns 135.0 ns 150.0 ns 225.0 ns 300.0 ns 375.0 ns 450.0 ns 600.0 ns 750.0 ns Absolute Min Oper. P.W. 16.0 ns 18.0 ns 20.0 ns 30.0 ns 40.0 ns 50.0 ns 60.0 ns 80.0 ns 100.0 ns Any dash number between 80 and 500 not shown is also available. 1996 Data Delay Devices Doc #96004 12/2/96 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 1 3D7010 APPLICATION NOTES To guarantee the Table 1 delay accuracy for input frequencies higher than the Maximum Operating Frequency, the 3D7010 must be tested at the user operating frequency. Therefore, to facilitate production and device identification, the part number will include a custom reference designator identifying the intended frequency of operation. The programmed delay accuracy of the device is guaranteed, therefore, only at the user specified input frequency. Small input frequency variation about the selected frequency will only marginally impact the programmed delay accuracy, if at all. Nevertheless, it is strongly recommended that the engineering staff at DATA DELAY DEVICES be consulted. OPERATIONAL DESCRIPTION The 3D7010 ten-tap delay line architecture is shown in Figure 1. The delay line is composed of a number of delay cells connected in series. Each delay cell produces at its output a replica of the signal present at its input, shifted in time. The delay cells are matched and share the same compensation signals, which minimizes tap-totap delay deviations over temperature and supply voltage variations. INPUT SIGNAL CHARACTERISTICS The Frequency and/or Pulse Width (high or low) of operation may adversely impact the specified delay accuracy of the particular device. The reasons for the dependency of the output delay accuracy on the input signal characteristics are varied and complex. Therefore a Maximum and an Absolute Maximum operating input frequency and a Minimum and an Absolute Minimum operating pulse width have been specified. OPERATING PULSE WIDTH The Absolute Minimum Operating Pulse Width (high or low) specification, tabulated in Table 1, determines the smallest Pulse Width of the delay line input signal that can be reproduced, shifted in time at the device output, with acceptable pulse width distortion. OPERATING FREQUENCY The Minimum Operating Pulse Width (high or low) specification determines the smallest Pulse Width of the delay line input signal for which the output delay accuracy tabulated in Table 1 is guaranteed. The Absolute Maximum Operating Frequency specification, tabulated in Table 1, determines the highest frequency of the delay line input signal that can be reproduced, shifted in time at the device output, with acceptable duty cycle distortion. To guarantee the Table 1 delay accuracy for input pulse width smaller than the Minimum Operating Pulse Width, the 3D7010 must be tested at the user operating pulse width. Therefore, to facilitate production and device identification, the part number will include a The Maximum Operating Frequency specification determines the highest frequency of the delay line input signal for which the output delay accuracy is guaranteed. IN O1 10% O2 10% O3 10% O4 10% O5 10% O6 10% O7 10% O8 10% O9 10% O10 10% Temp & VDD Compensation VDD GND Figure 1: 3D7010 Functional Diagram Doc #96004 12/2/96 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 2 3D7010 APPLICATION NOTES (CONT'D) custom reference designator identifying the intended frequency and duty cycle of operation. The programmed delay accuracy of the device is guaranteed, therefore, only for the user specified input characteristics. Small input pulse width variation about the selected pulse width will only marginally impact the programmed delay accuracy, if at all. Nevertheless, it is strongly recommended that the engineering staff at DATA DELAY DEVICES be consulted. POWER SUPPLY AND TEMPERATURE CONSIDERATIONS The delay of CMOS integrated circuits is strongly dependent on power supply and temperature. The monolithic 3D7010 programmable delay line utilizes novel and innovative compensation circuitry to minimize the delay variations induced by fluctuations in power supply and/or temperature. The thermal coefficient is reduced to 600 PPM/C, which is equivalent to a variation , over the 0C-70C operating range, of 3% from the room-temperature delay settings. The power supply coefficient is reduced, over the 4.75V5.25V operating range, to 2% of the delay settings at the nominal 5.0VDC power supply. It is essential that the power supply pin be adequately bypassed and filtered. In addition, the power bus should be of as low an impedance construction as possible. Power planes are preferred. DEVICE SPECIFICATIONS TABLE 2: ABSOLUTE MAXIMUM RATINGS PARAMETER DC Supply Voltage Input Pin Voltage Input Pin Current Storage Temperature Lead Temperature SYMBOL VDD VIN IIN TSTRG TLEAD MIN -0.3 -0.3 -1.0 -55 MAX 7.0 VDD+0.3 1.0 150 300 UNITS V V mA C C NOTES 25C 10 sec TABLE 3: DC ELECTRICAL CHARACTERISTICS (0C to 70C, 4.75V to 5.25V) PARAMETER Static Supply Current* High Level Input Voltage Low Level Input Voltage High Level Input Current Low Level Input Current High Level Output Current SYMBOL IDD VIH VIL IIH IIL IOH MIN -4.0 UNITS mA V V A A mA Low Level Output Current IOL 4.0 mA Output Rise & Fall Time TR & TF *IDD(Dynamic) = 10 * CLD * VDD * F where: CLD = Average capacitance load/tap (pf) F = Input frequency (GHz) Doc #96004 12/2/96 MAX 15 2.0 0.8 10 -250 2 ns NOTES VIH = VDD VIL = 0V VDD = 4.75V VOH = 2.4V VDD = 4.75V VOL = 0.4V CLD = 5 pf Input Capacitance = 10 pf typical Output Load Capacitance (CLD) = 25 pf max DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 3 3D7010 SILICON DELAY LINE AUTOMATED TESTING TEST CONDITIONS INPUT: Ambient Temperature: 25oC 3oC Supply Voltage (Vcc): 5.0V 0.1V Input Pulse: High = 3.0V 0.1V Low = 0.0V 0.1V Source Impedance: 50 Max. Rise/Fall Time: 3.0 ns Max. (measured between 0.6V and 2.4V ) Pulse Width: PWIN = 1.25 x Total Delay Period: PERIN = 2.5 x Total Delay OUTPUT: Rload: Cload: Threshold: 10K 10% 5pf 10% 1.5V (Rising & Falling) Device Under Test Digital Scope 10K 5pf 470 NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. PRINTER COMPUTER SYSTEM PULSE GENERATOR OUT IN TRIG DEVICE UNDER TEST (DUT) OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUT10 REF IN TRIG DIGITAL SCOPE/ TIME INTERVAL COUNTER Figure 2: Test Setup PERIN PW IN tRISE INPUT SIGNAL tFALL VIH 2.4V 1.5V 0.6V 2.4V 1.5V 0.6V tPLH OUTPUT SIGNAL VIL tPHL 1.5V VOH 1.5V VOL Figure 3: Timing Diagram Doc #96004 12/2/96 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 4