29/9/2011
MDFK 08G2124/N16
Magnetic sensors
Magnetic sensors
www.baumer.com
general data
air gap < 0,6 mm
pulse/revolution 512 pulses ring magnet 32 pole-pairs
measuring step 2048
interpolation 16 times
electrical data
switching frequency < 3200 kHz
voltage supply range +Vs 8 ... 28 VDC
current consumption max. 30 mA
output circuit 2 channel push-pull
output signal CH A/B
output current < 50 mA
voltage drop Vd < 2 VDC
short circuit protection yes
reverse polarity protection yes
mechanical data
type rectangular
housing material PC
dimension 15 mm
housing length 45 mm
connection types cable PUR 4 x 0,25, 2 m
ambient conditions
operating temperature -25 ... +85 °C
protection class IP 67
photo
dimension drawing
connection diagram
mounting