Electromagnetic Inductive RFID System V700 A High-functionality High-performance RFID System That Revolutionizes Product and Distribution Management in the Production Environment * A long transmission distance and a wide transmission range allow position displacement and axial offset of ID Tags to be handled with ease. * Reading and writing are possible with several ID Tags in the Antenna's transmission range, allowing use in new applications. * Easy-to-use, reasonably-priced ID Tags enable the creation of low-cost systems even in applications using a large number of Tags. * Availability of price effective Compact Reader V700HMD11(-1) * The lineup includes an ID Link Unit that is compatible with multi-drop connections and RS-485 interfaces. * The V700-HMD11-1 Compact Reader Writer can be connected directly to the ID Link Unit or an OMRON PLC without an AC Adapter. * CE marking. * FCC approvals and R&TTE Directive compliance. Ordering Information List of Models Name Model Specifications/Design V700-D23P31 20 dia. x t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes) V700-D23P41 3.9 dia. x 25 mm Stick-shaped 256 bytes (with user area of 240 bytes) V700-D23P61 40 x 40 x 4.5 mm Square tag 256 bytes (with user area of 240 bytes) ID Tag Holder V700-A80 Special holder for the V700-D23P31 (There is no ID Tag provided with the product.) Antenna V700-H01 (Standard Antenna) 250 x 200 x 35 mm 100-mm cable ID Tag Electromagnetic Inductive RFID System V700 1 Name Model Controller V700-CD1D-V3 Specifications/Design 90 x 65 x 75 mm V700-CD2D-V3 Antenna Cable RS-485 interface Maximum number of Controllers that can be connected: 31 24 VDC, 1 channel for Antenna connection V700-A40 2m V700-A41 3m V700-A42 5m V700-A43 10 m V700-A44 20 m V700-A45 30 m Compact Reader V700-HMD11 Writer 40 x 53 x 23 mm V700-HMD11-1 ID Link Unit V700-L12 Programming Console C200H-PRO27-E Programming Console Connecting Cable V700-P10 2 Electromagnetic Inductive RFID System V700 RS-232C interface 24 VDC, 1 channel for Antenna connection Material: Vinyl chloride The connector is not waterproof. RS-232C interface 5 VDC supplied via AC Adapter 2-m cable RS-232C interface 1-m cable 5 VDC supplied 2-m cable from connector 4-m cable 110 x 65 x 64 mm RS-232C and RS-485 interface Unit for multiple connections Equipped with the following functions: Execution status monitor, set value display, transmission execution, transmission test, noise measurement, reading error contents 2m Cable for connecting the V700-CD@DV@ and C200H-PRO27-E Specifications ID Tags Model V700-D23P61 V700-D23P31 V700-D23P41 Memory capacity 240 bytes (user area) 240 bytes (user area) 240 bytes (user area) Memory type EEPROM Data backup time 10 years after data written Data writing times 100,000 times per address Ambient operating temperature (during transmission) -20 to 70C (with no icing) -25 to 70C (with no icing) -10 to 70C -40 to 110C (with no icing) -10 to 70C (with no icing) Item Ambient operating -40 to 110C (with no icing) temperature (not during Heat resistance: transmission) Constant high temperature: 180C for 200 hours Thermal cycle: 25C/180C, 30 minutes, 200 cycles Ambient storage temperature -40 to 110C (with no icing) -40 to 110C (with no icing) -10 to 70C (with no icing) Ambient operating humidity No restrictions 35% to 95% (with no condensation) 35% to 85% Degree of protection IEC 60529: IP68 IEC 60529: IP67 IP67 (IEC 60529 standard) Vibration resistance 10 to 2,000 Hz, 0.75-mm single amplitude, 150-m/s2 acceleration with 10 sweeps of 15 min each in X, Y, and Z directions 10 to 2,000 Hz, 1.5-mm single amplitude, 150-m/s2 acceleration with 10 sweeps of 15 min each in X, Y, and Z directions Shock resistance 500-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total) 500-m/s2 acceleration for 3 times each in 6 directions, front/back, up/down, and left/right (18 times in total) Material PPS resin Case: PBT resin; Filling: Epoxy resin Case: ABS; Filling: Epoxy resin Weight Approx. 2 g Approx. 1 g Approx. 6 g Controllers Model V700-CD1D-V3 V700-CD2D-V3 Item Host interface RS-232C Number of connectable Antennas 1 RS-485 (Up to 31 Controllers can be connected.) Power supply voltage 24 VDC +10%/-15% Power consumption 20 W max. Insulation resistance 20 M min. (at 100 VDC) between the power supply terminals and ground terminal, power supply terminals and I/O terminals, power supply terminals and case, I/O terminals and ground terminal, I/O terminals and case, and ground terminal and case Dielectric strength 500 VAC (50/60 Hz, 1 minute) between the above terminals (leakage current: 10 mA max.) Vibration resistance 10 to 150 Hz, 0.30-mm double amplitude with 4 sweeps of 8 min each in X, Y, and Z directions Shock resistance 200-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature -10 to 55C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Electromagnetic Inductive RFID System V700 3 Model V700-CD1D-V3 V700-CD2D-V3 Item Ambient storage temperature -25 to 65C (with no icing) Ambient storage humidity 35% to 95% (with no condensation) Degree of protection IEC 60529: IP30 (panel mounted) Ground Ground at a resistance of less than 100 . If grounding is not performed properly, transmission specifications may be adversely affected by the surrounding environment. Weight Approx. 290 g Antennas Model V700-H01 Item Oscillation frequency 125 kHz Insulation resistance 20 M min. (at 500 VDC) between the cable terminals and the case Dielectric strength 1,000 VAC (50/60 Hz, 1 minute) between the cable terminals and the case (leakage current: 1 mA max.) Vibration resistance 10 to 150 Hz, 1.50-mm double amplitude with 2 sweeps of 8 min each in X, Y, and Z directions Shock resistance 300-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature -20 to 55C (with no icing) Ambient storage temperature -35 to 65C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Ambient storage humidity 35% to 95% (with no condensation) Degree of protection IEC 60529: IP40 (except connector) Material Case: PC/ASA resin; Rear panel: Phenol resin; PVC (The connector is not resistant to water or oil.) Cable length Maximum connection distance: 50.1 m using extension cable. Weight Approx. 800 g 4 Electromagnetic Inductive RFID System V700 Compact Reader Writers Model V700-HMD11-1 V700-HDM11 Item Host interface RS-232C Power consumption 5 VDC 5% Oscillating: 200 mA max.; Not oscillating: 25 mA max. Insulation resistance 50 M min. (at 500 VDC) between the cable terminals and the case Dielectric strength 1,000 VAC (50/60 Hz, 1 minute) between the cable terminals and the case (leakage current: 1 mA max.) Vibration resistance 10 to 150 Hz, 1.50-mm double amplitude with 4 sweeps of 8 min each in X, Y, and Z directions Shock resistance 300-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature -10 to 55C (with no icing) Ambient operating humidity 25% to 85% (with no condensation) Ambient storage temperature -25 to 65C (with no icing) Ambient storage humidity 25% to 95% (with no condensation) Degree of protection IEC 60529: IP67 The connector is not resistant to water or oil. Material Case: ABS resin; Filling: Epoxy resin; Cable: PVC (oil-resistant) Cable length 2 m (RS-232C signal lines can be extended up to a total 1, 2, 4 m length of 15 m.) Weight Approx. 210 g 5 VDC 5% (supplied via connector) 250 mA max. Approx. 210 g (2 m) Electromagnetic Inductive RFID System V700 5 ID Link Unit Item V700-L12 Host interface RS-232C or RS-485 (special 1:N protocol) Number of connectable Antennas 1 Power supply voltage 24 VDC +10%/-15% Power consumption 10 W max. Insulation resistance 50 M min. (at 500 VDC) between the power supply terminals and the ground terminal Dielectric strength 1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the ground terminal (leakage current: 5 mA max.) Vibration resistance 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s2 acceleration with 10 sweeps of 8 min each in X, Y, and Z directions Shock resistance 150-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature 0 to 40C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Ambient storage temperature -15 to 50C (with no icing) Ambient storage humidity 35% to 85% (with no condensation) Degree of protection IEC 60529: IP20 Ground Ground at a resistance of less than 100 . If grounding is not performed properly, transmission specifications may be adversely affected by the surrounding environment. Weight Approx. 185 g ID Tag Holder (for V700-D23P31 Coin-shaped ID Tag) Item V700-A80 Ambient storage temperature Conforms to the specifications for the V700-D23P31 Coin-shaped ID Tag. Ambient operating humidity No restrictions Material PPS resin Weight Approx. 5 g 6 Electromagnetic Inductive RFID System V700 System Configuration Programming Console ID Tag Antenna Antenna Cable Controller C200H-PRO27-E V700-CD2D-V3 RS-485 interface V700-A40 -A41 -A42 -A43 -A44 -A45 V700-D23P31 Host device with RS-485 interface Programming Console Conversion Cable V700-P10 Holder for V700-D23P31 V700-CD1D-V3 RS-232C interface V700-H01 V700-A80 Compact Reader Writer (Combined Antenna and Controller) Host device with RS-232C interface V700-HMD11 V700-D23P41 V700-HMD11-1 ID Link Unit V700-D23P61 V700-L12 Programmable Controller CPM2C Series Note: The V700-CD1D-V3, V700-HMD11(-1), and V700-L12 all have different function and command structures. Electromagnetic Inductive RFID System V700 7 Functions Transmission Functions V700-CD1D-V3 V700-CD2D-V3 V700-HMD11 V700-HMD11-1 Single access Provided Provided FIFO Provided Provided Multiple access Provided Not provided Selective access Provided Not provided Note: The V700-CD@D-V@ and V700-HMD11(-1) have different command structures. Transmission Time (Reference) The transmission time is the time required for transmission between the Antenna and ID Tag and does not include time required for host communications. V700-CD@D-V@ Asynchronous Read-only synchronization Read-write synchronization Write T = 52.8 N + 113.5 Read T = 46.7 N + 60.7 Read T = 46.7 N + 107.4 Write T = 52.8 N + 172.4 Read T = 52.8 N + 119.6 V700-HMD11/HMD11-1 Precautions on Using the Product near Noise Sources This product makes transmissions to ID Tags using a frequency of 125 kHz. Transceivers, motors, monitoring devices, and power supplies have parts that generate electromagnetic waves (noise). These waves may interfere with transmissions to ID Tags. Before using this product near these kinds of devices, check that there is no adverse affect on transmissions. Multiple Access with the V700-CD@D-V@ Read T = 48 N + 66 Write T = 55 N + 120 The transmission time when using multiple-access commands not only depends on the number of bytes, but also on the number of ID Tags in the transmission range and the combination of the ID Tags' codes. The average values for random ID codes are given below. (units: ms) Note: T = Transmission time (ms) N = Number of pages (1 page = 8 bytes) Number of Tags Reading 8 bytes 5 579 Writing 8 bytes 873 10 1,191 1,547 15 1,857 2,275 20 2,523 3,002 30 3,853 4,455 50 6,344 7,192 Mutual Interference Prevention Functions (Using the V700-CD@D-V@) If there is less than 15 m between Antennas, all the Antennas must be synchronized to prevent mutual interference. This can be done using either of the two methods described below. Read-only Synchronization Read/Write Synchronization If all the Antennas only use read commands, this method can be used to reduce the access time. This is the synchronization method that is usually used. It enables the synchronization of both read and write commands for several connected Antennas. ID Controllers Antennas ID Controllers Antennas 1 m min. Read 8 Read 1 m min. Read 1 m min. Read 1 m min. Read Electromagnetic Inductive RFID System V700 1 m min. Read Read 1 m min. Write 1 m min. 1 m min. Read/Write Read Characteristic Data (Typical) Transmission Range Antenna Operation Range Graphs V700-H01 & V700-D23P31 V700-CH1D & V700-D23P61 Y Y X V700-CH1D (-1) 40 30 X Y 20 30 V700-H01 Tag Y 20 Tag 10 -40 -30 -20 -10 10 0 10 20 30 40 X cm -40 -30 -20 -10 0 10 20 30 40 X mm V700-HMD11(-1) & V700-D23P31 Y V700-HMD11(-1) 50 X 40 Y Tag 30 20 10 -50 -40 -30 -20 -10 0 10 20 30 40 50 X mm V700-H01 & V700-D23P41 Y X 30 Y V700-H01 Tag 20 10 -40 -30 -20 -10 0 10 20 30 40 X cm V700-HMD11(-1) & V700-D23P41 Y V700-HMD11(-1) 50 X 40 Y Tag 30 20 10 -50 -40 -30 -20 -10 0 10 20 30 40 50 X mm V700-HMD11 & V700-D23P61 Y V700-HMD11 X 80 60 Y Tag 40 20 -80 -60 -40 -20 0 20 40 60 80 X mm Electromagnetic Inductive RFID System V700 9 Dimensions Note: All units are in millimeters unless otherwise indicated. ID Tag ID Tag Holder (for V700-D23P31) V700-D23P31 Coin-shaped ID Tag V700-D23P41 Stick-shaped ID Tag V700-A80 40 20 dia.+0.05 Two, 6-dia. 22 Two, 3.5-dia. 310.1 250.1 3.9 dia.0.1 3.5 1.5 R1 1.1 2.7 dia.0.1 5 8 R0.25 16 dia. 20 dia. 1 0.2 V700-D23P61 Square Tags 22 8 Mounting Hole Dimensions 5.2 8 13.2 Two, M3 5.2 8 13.2 16 400.1 -0.5 320.2 0.2 16 Mounting reference surface 8 Two, 3.5 dia. mounting holes 16 16 400.1 -0.5 2 4.5 Antenna V700-H01 Standard Antenna 200 1850.2 Four, 5-dia. 85 142.5 2350.2 250 40 13.5 78.8 21 20 max. 7.5 30 100 44.5 16 max. 10 Electromagnetic Inductive RFID System V700 320.2 Case: ABS Filling: Epoxy resin Compact Reader Writer V700-HMD11 Two, 10-dia. Two, 4.5-dia. mounting holes 6 dia., length: 2 m Bushing 5 32 28 40 10 Four, R1 5 27 53 20 11 dia Operation indicator 6 Length: 190 34 45.5 5 13 18 11 15 23 . Connector:EIAJRC5320AJSAP2(receptacle) V700-HMD11-1 6 dia., length: 1 m, 2 m, 4 m Bushing 32 40 5 Two, 4.5-dia. mounting holes 10 Two, 10-dia. 280.1 Four, R1 45.5 5 27 Operation indicator 13 18 20 11 15 23 53 5 6 Controller V700-CD1D-V3 10 66 75 8 4 10 Power indicator 4 4 4 Operation indicator 21 18 90 100 17.5 10 10 56 Two, 4.5-dia. mounting holes V700-CD2D-V3 10 10 66 75 8 4 Power indicator 4 4 4 Operation indicator 21 18 90 100 17.5 10 56 10 Two, 4.5-dia. mounting holes Electromagnetic Inductive RFID System V700 11 ID Link Unit V700-L12 110 41.5 26.5 41.3 18.5 20.3 65 16.7 10.7 35.2 5 Two, 4.5-dia. 4 4 Mounting Hole Dimensions 550.2 Two, M4 or 4.2-dia. 1100.2 12 Electromagnetic Inductive RFID System V700 60 READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. 16 Electromagnetic Inductive RFID System V700 Cat. No. Q111-E2-04 OMRON Corporation 2007. 3 In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.