Voltage monitoring in 3-phase mains G2PF...S02 Monitoring relays - GAMMA series Monitoring of phase sequence and phase failure Detection of reverse voltage Connection of neutral wire optional Supply voltage = measuring voltage 2 change-over contacts Width 22.5mm Industrial design Technical data 1. Functions Monitoring of phase sequence, phase failure and detection of return voltage (by means of evaluating the asymmetry) 2. Time ranges Start-up suppression time: Tripping delay: Adjustment range fixed, max. 500ms fixed, max. 350ms 3. Indicators Green LED ON: Yellow LED ON/OFF: indication of supply voltage indication of relay output 4. Mechanical design Self-extinguishing plastic housing, IP rating IP40 Mounted on DIN-Rail TS 35 according to EN 60715 Mounting position: any Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 Tightening torque: max. 1Nm Terminal capacity: 1 x 0.5 to 2.5mm with/without multicore cable end 1 x 4mm without multicore cable end 2 x 0.5 to 1.5mm with/without multicore cable end 2 x 2.5mm flexible without multicore cable end 5. Input circuit Supply voltage: 3(N)~ 115/66V 3(N)~ 230/132V 3(N)~ 400/230V Tolerance: 3(N)~ 115/66V 3(N)~ 230/132V 3(N)~ 400/230V Rated frequency: Rated consumption: 3(N)~ 115/66V 3(N)~ 230/132V 3(N)~ 400/230V Duration of operation: Reset time: Residual ripple for DC: Drop-out voltage: Overvoltage category: Rated surge voltage: terminals (N)-L1-L2-L3 (G2PF115VS02) (= measuring voltage) terminals (N)-L1-L2-L3 (G2PF230VS02) (= measuring voltage) terminals (N)-L1-L2-L3 (G2PF400VS02) (= measuring voltage) 3(N)~ 99 to 132V (G2PF115VS02) 3(N)~ 198 to 264V (G2PF230VS02) 3(N)~ 342 to 457V (G2PF400VS02) 48 to 63Hz 3VA (G2PF115VS02) 6VA (G2PF230VS02) 9VA (G2PF400VS02) 100% <100ms >20% of the supply voltage III (in accordance with IEC 60664-1) 4kV Mechanical life: Electrical life: Switching frequency: Overvoltage category: Rated surge voltage: 7. Measuring circuit Measured variable: Input: 3(N)~ 115/66V 3(N)~ 230/132V 3(N)~ 400/230V Overload capacity: 3(N)~ 115/66V 3(N)~ 230/132V 3(N)~ 400/230V Input resistance: 3(N)~ 115/66V 3(N)~ 230/132V 3(N)~ 400/230V 20 x 106 operations 2 x 105 operations at 1000VA resistive load max. 60/min at 100VA resistive load max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) III (in accordance with IEC 60664-1) 4kV AC Sinus, 48 to 63Hz terminals (N)-L1-L2-L3 (G2PF115VS02) (= supply voltage) terminals (N)-L1-L2-L3 (G2PF230VS02) (= supply voltage) terminals (N)-L1-L2-L3 (G2PF400VS02) (= supply voltage) 3(N)~ 132/76V (G2PF115VS02) 3(N)~ 264/152V (G2PF230VS02) 3(N)~ 457/264V (G2PF400VS02) 5k (G2PF115VS02) 10k (G2PF230VS02) 15k (G2PF400VS02) Asymmetry: Overvoltage category: Rated surge voltage: fixed, typ. 30% III (according to IEC 60664-1) 4kV 8. Accuracy Base accuracy: Frequency response: Adjustment accuracy: Repetition accuracy: Voltage influence: Temperature influence: 3% (of maximum scale value) 2% 0.05% / C 9. Ambient conditions Ambient temperature: Storage temperature: Transport temperature: Relative humidity: Pollution degree: Vibration resistance: Shock resistance: 6. Output circuit 2 potential free change-over contacts Rated voltage: 250V AC Switching capacity (distance <5mm): 750VA (3A / 250V AC) Switching capacity (distance >5mm): 1250VA (5A / 250V AC) Fusing: 5A fast acting www.tele-online.com -25 to +55C (in accordance with IEC 60068-1) -25 to +40C (in accordance with UL 508) -25 to +70C -25 to +70C 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) 3 (in accordance with IEC 60664-1) 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) 15g 11ms (in accordance with IEC 60068-2-27) G2PF...S02 Functions Connections Phase sequence monitoring When all the phases are connected in the correct sequence and the measured asymmetry is less than the fixed value, the output relays switch into on-position (yellow LED illuminated). When the phase sequence changes, the output relays switch into off-position (yellow LED not illuminated). Detection of reverse voltage (by means of evaluation of asymmetry) The output relays switch into off-position (yellow LED not illuminated) when the asymmetry between the phase voltages exceeds the fixed value of the asymmetry. An asymmetry caused by the reverse voltage of a consumer (e.g. a motor which continues to run on two phases only) does not effect the disconnection. Dimensions Phase failure monitoring When one of the three phases fails, the output relays switch into off-position (yellow LED not illuminated). RELEASE 2009/07 Subject to alterations and errors www.tele-online.com