Proximity Sensors 973EX Series
18 mm & 30 mm Diameter Hazardous Location Stainless Steel Sensor
2-wire AC/DC Universal Voltage Type
B52 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1UL 698 Explosion-Proof rating for
Division 1, Class I, Groups A, B, C, D,
Class II, Groups E, F, G, and Class III
Hazardous Locations. File #E68427
1Time proven inductive proximity
technology with solid state electronics
1No external barriers are required as with
intrinsically safe devices
1All stainless steel sensor and sensing
face for reliable operation in harsh duty
environments
1Non-contact sensing
1Universal supply voltage: 20 to 250
VAC/VDC
1Energy limiting circuitry – overload
protection, short circuit protection
standard
ORDER GUIDE
Sensor Sensing Standard
Package Range Sensor Sw. Target* Output Catalog
Style mm (in.)* Type LED Freq. mm (in.) Type Listing
18 (.71) 3 (.118) 2-wire NO 15 Hz 50,8 (2.0) N.O. 973EX3WI-A10T
Shielded AC/DC
30 (1.18) 7 (.276) 2-wire NO 15 Hz 50,8 (2) N.O. 973EX4WI-A10T
Shielded AC/DC
*Not designed to sense stainless steel.
SPECIFICATIONS
Supply Voltage 20 to 250 VAC/VDC
Load Current, min.-max. 5 to 500 mA
Inrush Current 2 amps 10 ms; frequency 5 kHz
Leakage Current 2.0 mA @ 20-250 VAC
1.7 mA @ 20-200 VAC
Noise Immunity Passes NEMA noise standard ICS 2-230
Voltage Drop 7 V max. @ 500 mA
Repeatability ±1%
Hysteresis 2 to 15%
Operating Temperature 20°C to +70°C (– 4 °F to +158°F)
Switching Frequency, max. 15 Hz
LED None
Protection class NEMA 4, 4X, 6P, 13
Shock 10 G
Vibration 10 G, 10 to 110 Hz
Standard target 50,8 x 50,8 x 12.7 mm (2 x 2 x .50 in.) CRS (Cold Rolled Steel)
Material
Housing/Sensing Face Stainless Steel
Cable PVC 3 conductor, 18 gage (UL approved)
Proximity Sensors 973EX Series
18 mm and 30 mm Diameter Hazardous Location Stainless Steel Sensor
2-Wire AC/DC Universal Voltage Type
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada B53
WIRING DIAGRAM
Connecting cables may be run in conduit
with other control wiring without affecting
operation. However, they should not be
placed in conduit with power wiring. Class 1
wiring is required.
MOUNTING DIMENSIONS
(For reference only)
mm
in.
18 mm
30 mm
The 973EX Series is approved for hazardous locations. It may be made suitable for
explosive atmospheres with the application of special explosion proof seal fittings
and conduit as required by the National Electrical Code (NEC), Article 500.
MICRO SWITCH does not supply these fittings and conduit. It is the responsibility of the
purchaser or installer to supply the required material.
Proximity