GC120 120W Single Output Battery Charger series Features : Charger for lead-acid batteries (flooded,Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese) (Note.1) 2 stage charging characteristic Universal AC input / Full range Built-in active PFC function, PF>0.97 No load power consumption<0.5W 3 pole AC inlet IEC320-C14 Class I power ( with earth pin) Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Fully enclosed plastic case 2 color LED indicator for charging status Approvals: UL / PSE / TUV / EAC / CB / FCC / CE 2 years warranty ( for GC120Axx-AD1 only) EN62368-1 TPTC004 IEC62368-1 ORDER NO. OUTPUT CONNECTOR SAFETY GC120Axx-R7B (standard model) 4pin power din TUV / CB / FCC / CE / EAC GC120Axx-AD1 (optional model) Anderson connector UL / TUV / CB / FCC / CE / EAC GC120Axx- xx=12,24,48 ; =R7B,AD1 SPECIFICATION ORDER NO. GC120A12- GC120A24- GC120A48- GC120A12 13.6V GC120A24 27.2V GC120A48 54.4V RECOMMENDED BATTERY 40 ~ 100Ah Note.3 CAPACITY 20 ~ 65Ah 10 ~ 35Ah CONTINUOS OUTPUT CURRENT (Typ.) 7.5A 4.42A 2.21A RATED POWER 102W 120.2W 120.2W SAFETY MODEL NO. DC VOLTAGE (Typ.) OUTPUT LED INDICATOR VOLTAGE RANGE INPUT Charging(CC) : RED Floating charging(CV) : GREEN Note.4 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.97 / 230VAC EFFICIENCY (Typ.) 86.5% AC CURRENT INRUSH CURRENT (max.) 1.4A / 115VAC LEAKAGE CURRENT(max.) 0.75mA / 240VAC OVERLOAD OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 6) EMC EMISSION EMC IMMUNITY OTHERS CONNECTOR NOTE 90% 91% 0.7A / 230VAC 70A / 230VAC 90 ~ 110% rated output power Note.5 Protection type : Constant current limiting recovers automatically after fault condition is removed SHORT CIRCUIT PROTECTION PF>0.99 / 115VAC at full load Protection type : Hiccup mode, recovers automatically after fault condition is removed 14 ~ 16.5V 29 ~ 33V 59 ~ 69V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03% / (0~50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012 (FOR GC120AXX-AD1 Only), TUV EN62368-1, PSE J60950-1, EAC TP TC 004 approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 class B, FCC PART 15 / CISPR22 class B,CAN ICES-3(B)/NMB-3(B), EN61000-3-2,3, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020 400.7Khrs min. MIL-HDBK-217F(25) MTBF DIMENSION PACKING PLUG 167*67*35mm (L*W*H) 0.62Kg; 20pcs/13.4Kg/0.9CUFT See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 3. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. Constant current operation region is within 50~100% rated output voltage. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:GC120-SPEC 2019-12-27 GC120 120W Single Output Battery Charger Mechanical Specification 35 Case No.947A series Unit:mm UL2464 18AWGx4C 1200 50mm 167 67 30 3mm (R7B) POWER LED 35 SJTW 18AWGx2C 1200 50mm 167 67 30 3mm (AD1) POWER LED Charging Curve Plug Assignment DC output connector (standard) (V,I) R7B (KYCON KPP-4S or equivalent) Stage 1 Stage 2 Constant Current Area Constant Voltage Area PIN NO. OUTPUT 2 1 3 4 1,4 +V 2,3 -V V 100% AC FG -V connected to AC FG Fast Charging DC output connector (optional) AD1 [ housing: Anderson 1327FP(red), 1327G6FP(black) contacts: Anderson 261G2 (45A) or equivalent ] Red(+V) 10% Float Charging Color of LED Red I TIME Green Black(-V) Suitable for lead-acid batteries (flooded,Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese) File Name:GC120-SPEC 2019-12-27 GC120 120W Single Output Battery Charger Derating Curve series Static Characteristics 100 230VAC 100 85 80 80 70 100VAC LOAD (%) LOAD (%) 60 50 40 20 -30 10 20 30 40 45 50 60 AMBIENT TEMPERATURE () 70 (HORIZONTAL) 60 50 40 85 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GC120-SPEC 2019-12-27