SPECIFICATION CONTROL DRAWING 4440311 WIRE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED, 28MAR14 L4 LIGHTWEIGHT, GENERAL PURPOSE, 2500 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 44. PRIMARY INSULATION - RADIATION-CROSSLINKED, CONDUCTOR - TIN-COATED COPPER EXTRUDED POLYALKENE JACKET - RADIATION-CROSSLINKED, MODIFIED PVDF Thickness: AWG 26- 4, .005 + .001 in. AWG 2 -00, .010 + .002 in. TABLE |. CONSTRUCTION DETAILS DIAMETER OF FINISHED WIRE PART NUMBER S2E STRANDING. CONDUCTOR RESISTANCE DIAMETER MAXIMUM V (AWG) | (number x AWG) (in.) AT 20C (in) {lba/1000 ft ; MINIMUM | MAXIMUM | (ohms/1000 ft) 4440311-26-* 26 19x38 .018 .020 41.3 .053 + .002 2.1 4440311-24-* 24 19 x 36 .023 .025 26.2 .057 + .002 3.0 4440311-22-* 22 19 x34 029 .033 16.2 .069 + .003 4.3 44.0311-20-* 20 19 x32 037 O41 9.88 078 + .003 6.1 44.A0311-18-* 18 19 x 30 046 051 6.23 088 + .003 8.7 4440311-16-* 16 19 x29 .052 .058 4.31 .097 + .004 10.9 4440311-14-* 14 19x27 .065 .073 3.06 115 + .004 16.2 44A0311-12-* 12 37 x 28 084 .090 2.02 131 + .004 24.2 44.A0311-10-* 10 37 x 26 106 114 1.26 161 + .005 36.5 44A40311-8-* 8 133 x 29 158 173 701 219 + 006 65.0 44A0311-6-* 6 133 x 27 .198 217 445 .269 + .007 103. 44A0311-4-* 4 133 x 25 250 274 .280 .325 + .008 158. 4440311 2-* 2 665 x 30 320 .340 183 404+ 012 252. 44A0311-0-* 0 1045 x 30 405 425 116 494+ 016 380. 44.0311-00-* 00 1330 x 30 450 475 092 545 + 016 459. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves ihe right io make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ CGLGORS AND CGLGR CGDE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TE Connectivity To THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER The TE logo, TE Connectivity and Raychem are trademarks. TE Connectivity Wire & Cable aD 301 Oakside Avenue DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL = Redwood City, CA 94063-3800 Page 1 of 3 oe Phone 1-800-227-8816 THIS SPEGIFIGATION SHEET TAKES PREGEDENSE OVER DOCUMENTS REFERENCED HEREIN. TE Connectivity Fax. 1-650-361-6207 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.@ TE | SPECIFICATION CONTROL DRAWING| recezo3 | tr | 44A0311 TE Connectivity TABLE Il. PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER WEIGHT PART NUMBER (inch) (+ 3%) (Ib) (+ 3%) A IMMERSION COLD IMMERSION LIFE CYCLE AND BEND LIFE CYCLE AND AGCELERATED AGING ACCELERATED AGING 44A0311-26-* 500 1.00 . 625 44A0311-24-* 500 1.00 . 625 44A0311-22-* 750 1.00 . 2.00 44A0311-20-* 750 1.00 . 2.50 44A0311-18-* 1.00 1.50 . 2.50 44A0311-16-* 1.00 1.50 . 2.50 44A0311-14-* 1.50 2.00 . 2.50 44A0311-12-* 2.00 2.00 . 3.00 44A0311-10-* 3.00 3.00 . 3.00 44403 11-8-* 3.00 4.00 . 6.00 44403 11-6-* 4.00 5.00 6.00 44A0311-4-* 5.00 6.00 6.00 44A0311-2-* 6.00 8.00 6.00 44A0311-0-* 8.00 10.0 7.00 44A0311-00-* 9.00 12.0 7.00TE | sPeEcIFICATION CONTROL DRAWING| eee303 | 1; TE Connectivity SCD Number 44A0311 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 2500 volts (rms) at sea level ACCELERATED AGING: 300 + 2 for 6 hours Identification legibility, 225 + 2C for 6 hours BLOCKING: 150+ 2C for 24 hours COLOR: White preferred FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft. (minimum) IDENTIFICATION AND COLOR STRIPING DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown. INSULATION ELONGATION AND TENSILE STRENGTH: 1.5 inch jaw separation, 2.0 inch/minute crosshead speed Primary Insulation, Elongation, 150% (minimum) Tensile Strength, 2500 Ibf/in? (minimum), AWG 26-12 2000 Ibffin? (minimum), AWG 10-00 INSULATION FLAWS: Primary Insulation, Spark Test, 5.0 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) Finished Wire, Spark Test, 8.0 kV (rms) at 3 kHz Impulse Dielectric Test, 13.0 kV (peak) INSULATION RESISTANCE: 5000 megohms for 1000 ft. (minimum) LIFE CYCLE: 200 + 2 for 168 hours LOW TEMPERATURE-COLD BEND: -65 + 2 for 4 hours SHRINKAGE: 300 + 2C, 0.125 in. (maximum) in 12 in., AWG 26-12 300 + 2C, 0.250 in. (maximum) in 12 in., AWG 10-00 SMOKE: 200 + 2C. No visible smoke. SURFACE RESISTANCE: 500 megohms-in. (minimum), both readings THERMAL SHOCK RESISTANCE: 150 + 2C, 0.060 in. (maximum) VOLTAGE WITHSTAND (Post Environmental): 5000 volts (rms), 60 Hz, 5 minutes WICKING: 2.25 in. (maximum) PART NUMBER: The "*" in the part numbers on pages 1 and 2 shall be replaced by color code designators. 41/ Example: AWG 20, white: 44A0311-20-9 AWG 20, white with black stripe: 4440311-20-90 1/ See footer section on page 1