LYT4211-4218/4311-4318
LYTSwitch-4 High Power LED Driver IC Family
Single-Stage Accurate Primary-Side Constant Current (CC) Controller with
PFC for Low-Line Applications with TRIAC Dimming and Non-Dimming Options
Part Number Input Voltage Range TRIAC Dimmable
LY T42 21-LY T42 28 160-300 VAC No
LY T4321- LY T4328 160-300 VAC Yes
Output Power Table
Product Minimum Output Power Maximum Output Power
LYT4x21E 6 W 12 W
LYT4x22E 6 W 15 W
LYT4x23E 8 W 18 W
LYT4x24E 9 W 22 W
LYT4x25E 11 W 25 W
LYT4x26E 14 W 35 W
LYT4x27E 19 W 50 W
LYT4x28E 33 W 78 W
Optimized for Different Applications and Power Levels
Part Number Input Voltage Range TRIAC Dimmable
LY T4211-LY T4218 85-132 VAC No
LY T4311- LY T4318 85 -132 VAC Yes
Output Power Table
Product Minimum Output Power Maximum Output Power
LYT4x11E 2.5 W 12 W
LYT4x12E 2.5 W 15 W
LYT4x13E 3.8 W 18 W
LYT4x14E 4.5 W 22 W
LYT4x15E 5.5 W 25 W
LYT4x16E 6.8 W 35 W
LYT4x17E 8.0 W 50 W
LYT4x18E 18 W 78 W
Optimized for Different Applications and Power Levels
Click Here
To read about
LYTSwitch-4 Low-Line
Click Here
To read about
LYTSwitch-4 High-Line
LYT4221-4228/4321-4328
LYTSwitch-4 High Power LED Driver IC Family
Single-Stage Accurate Primary-Side Constant Current (CC) Controller with
PFC for High-Line Applications with TRIAC Dimming and Non-Dimming Options
This page intentionally left blank
LYT4211-4218/4311-4318
LYTSwitch-4 High Power LED Driver IC Family
www.power.com November 2014
Single-Stage Accurate Primary-Side Constant Current (CC) Controller with
PFC for Low-Line Applications with TRIAC Dimming and Non-Dimming Options
This Product is Covered by Patents and/or Pending Patent Applications.
Product Highlights
Better than ±5% CC regulation
TRIAC dimmable to less than 5% output
Fast start-up
<250 ms at full brightness
<1s at 10% brightness
High power factor >0.9
Easily meets EN61000-3-2
Less than 10% THD in optimized designs
Up to 92% efficient
132 kHz switching frequency for small magnetics
High Performance, Combined Driver, Controller, Switch
The LYTSwitch-4 family enables off-line LED drivers with high
power factor which easily meet international requirements for
THD and harmonics. Output current is tightly regulated with
better than ±5% CC tolerance1. Efficiency of up to 92% is easily
achieved in typical applications.
Supports a Wide Selection of TRIAC Dimmers
The LYTSwitch-4 family provides excellent turn-on characteristics
for leading-edge and trailing-edge TRIAC dimming applications.
This results in drivers with a wide dimming range and fast
start-up, even when turning on from a low conduction angle –
large dimming ratio and low “pop-on” current.
Low Solution Cost and Long Lifetime
LYTSwitch-4 ICs are highly integrated and employ a primary-side
control technique that eliminates the optoisolator and reduces
component count. This allows the use of low-cost single-sided
printed circuit boards. Combining PFC and CC functions into a
single-stage also helps reduce cost and increase efficiency.
The 132 kHz switching frequency permits the use of small,
low-cost magnetics.
LED drivers using the LYTSwitch-4 family do not use primary-
side aluminum electrolytic bulk capacitors. This means greatly
extended driver lifetime, especially in bulb and other high
temperature applications.
Figure 1. Typical Schematic.
PI-6800-050913
LYTSwitch-4
AC
IN
D
S
BP
V
FBR
CONTROL
Part Number Input Voltage Range TRIAC Dimmable
LY T4211-LY T4218 85-132 VAC No
LY T4311- LY T4318 85 -132 VAC Yes
Output Power Table1,2
Product6Minimum Output Power3Maximum Output Power 4
LYT4x11E52.5 W 12 W
LYT4x12E 2.5 W 15 W
LYT4x13E 3.8 W 18 W
LYT4x14E 4.5 W 22 W
LYT4x15E 5.5 W 25 W
LYT4x16E 6.8 W 35 W
LYT4x17E 8.0 W 50 W
LYT4x18E 18 W 78 W
Table 1. Output Power Table.
Notes:
1. Performance for typical design. See Application Note.
2. Continuous power in an open-frame design with adequate heat sinking; device
local ambient of 70 °C. Power level calculated assuming a typical LED string
voltage and efficiency >80%.
3. Minimum output power requires CBP = 47 µF.
4. Maximum output power requires CBP = 4.7 µF.
5. LYT4311 CBP = 47 µF, LYT4211 CBP = 4.7 µF.
6. Package: eSIP-7C (see Figure 2).
Figure 2. Package Options.
eSIP-7C (E Package)
Optimized for Different Applications and Power Levels
Rev. E 11/14
2
LYT4211-4218/4311-4318
www.power.com
Figure 3d. Typical Buck-Boost Schematic.
Figure 3c. Typical Tapped-Buck Schematic.
Figure 3b. Typical Buck Schematic.
Figure 3a. Typical Isolated Flyback Schematic.
Table 2. Performance of Different Topologies in a Typical Non-Dimmable 10 W Low-Line Design.
PI-6800-050913
LYTSwitch-4
AC
IN
D
S
BP
V
FBR
CONTROL
Topology Isolation Efficiency Cost THD Output Voltage
Isolated Flyback Yes 88% High Best Any
Buck No 92% Low Good Limited
Tapped-Buck No 89% Middle Best Any
Buck-Boost No 90% Low Best High-Voltage
PI-6841-111813
D
S
BP
V
FBR
CONTROL
AC
IN
LYTSwitch-4
PI-6842-111813
D
S
CONTROL
AC
IN V
FBR
LYTSwitch-4
BP
Typical Circuit Schematic Key Features
Flyback
Benefits
Provides isolated output
Supports widest range of output voltages
Very good THD performance
Limitations
Flyback transformer
Overall efficiency reduced by parasitic capacitance
and inductance in the transformer
Larger PCB area to meet isolation requirements
Requires additional components (primary clamp and bias)
Higher RMS switch and winding currents increases losses
and lowers efficiency
Buck
Benefits
Highest efficiency
Lowest component count – small size
Simple low-cost power inductor
Low drain source voltage stress
Best EMI/lowest component count for filter
Limitations
Single input line voltage range
Output voltage <0.6 × VIN(AC) × 1.41
Output voltage for low THD designs
Non-isolated
Tapped-Buck
Benefits
Ideal for low output voltage designs (<20 V)
High efficiency
Low component count
Simple low-cost tapped inductor
Limitations
Designs best suited for single input line voltage
Requires additional components (primary clamp)
Non-isolated
Buck-Boost
Benefits
Ideal for non-isolated high output voltage designs
High efficiency
Low component count
Simple common low-cost power inductor can be used
Lowest THD
Limitations
Maximum VOUT is limited by MOSFET breakdown voltage
Single input line voltage range
Non-isolated
D
S
BP
V
FBR
CONTROL
AC
IN
LYTSwitch-4
PI-6859-111813
Rev. E 11/14
3
LYT4211-4218/4311-4318
www.power.com
Figure 5. Pin Configuration.
Pin Functional Description
DRAIN (D) Pin:
This pin is the power FET drain connection. It also provides
internal operating current for both start-up and steady-state
operation.
SOURCE (S) Pin:
This pin is the power FET source connection. It is also the
ground reference for the BYPASS, FEEDBACK, REFERENCE
and VOLTAGE MONITOR pins.
BYPASS (BP) Pin:
This is the connection point for an external bypass capacitor for
the internally generated 5.9 V supply. This pin also provides
output power selection through choice of the BYPASS pin
capacitor value.
FEEDBACK (FB) Pin:
The FEEDBACK pin is used for output voltage feedback. The
current into the FEEDBACK pin is directly proportional to the
output voltage. The FEEDBACK pin also includes circuitry to
protect against open load and overload output conditions.
REFERENCE (R) Pin:
This pin is connected to an external precision resistor and is
used to configure for dimming (LYT4311-4318) and non-TRIAC
dimming (LYT4211-4218) modes of operation.
VOLTAGE MONITOR (V) Pin:
This pin interfaces with an external input line peak detector,
consisting of a rectifier, filter capacitor and resistors. The
applied current is used to control stop logic for overvoltage (OV),
provide feed-forward to control the output current and the
remote ON/OFF function.
PI-6843-071112
ILIM
DRAIN (D)
SOURCE (S)
BYPASS (BP)
VOLTAGE
MONITOR (V)
FEEDBACK (FB)
REFERENCE (R)
ILIM
VSENSE
MI
IS
5.9 V
5.0 V
BYPASS PIN
UNDERVOLTAGE
FAULT
PRESENT
Gate
Driver
SenseFet
OCP
CURRENT LIMIT
COMPARATOR
1 V
6.4 V
FBOFF
FBOFF
IFB
IV
DCMAX
DCMAX
Comparator
5.9 V
REGULATOR
SOFT-START
TIMER
JITTER
CLOCK
OSCILLATOR
AUTO-RESTART
COUNTER
BYPASS
CAPACITOR
SELECT
FEEDBACK
SENSE
PFC/CC
CONTROL
LINE
SENSE
HYSTERETIC
THERMAL
SHUTDOWN
+
-
+
-
+
-
3-VT
VBG
OV
REFERENCE
BLOCK
LEB
MI
VBG
STOP
LOGIC
Figure 4. Functional Block Diagram.
PI-7076-062513
Exposed Pad
(Backside) Internally
Connected to
SOURCE Pin (see
eSIP-7C Package
Drawing)
E Package (eSIP-7C)
(Top View)
1 R
2 V
3 FB
4 BP
5 S
7 D
Rev. E 11/14
4
LYT4211-4218/4311-4318
www.power.com
Functional Description
A LYTSwitch-4 device monolithically combines a controller and
high-voltage power FET into one package. The controller
provides both high power factor and constant current output in
a single-stage. The LYTSwitch-4 controller consists of an
oscillator, feedback (sense and logic) circuit, 5.9 V regulator,
hysteretic over-temperature protection, frequency jittering,
cycle-by-cycle current limit, auto-restart, inductance correction,
power factor and constant current control.
FEEDBACK Pin Current Control Characteristics
The figure shown below illustrates the operating boundaries of
the FEEDBACK pin current. Above IFB(SKIP) switching is disabled
and below IFB(AR) the device enters into auto-restart.
Figure 6. FEEDBACK Pin Current Characteristic.
The FEEDBACK pin current is also used to clamp the maximum
duty cycle to limit the available output power for overload and
open-loop conditions. This duty cycle reduction characteristic
also promotes a monotonic output current start-up characteristic
and helps preventing over-shoot.
REFERENCE Pin
The REFERENCE pin is tied to ground (SOURCE) via an external
resistor. The value selected sets the internal references,
determining the operating mode for dimming (LYT4311-4318)
and non-dimming (LYT4211-4218) operation and the line
overvoltage thresholds of the VOLTAGE MONITOR pin.
For non-dimming or PWM dimming applications with LYT4211-
4218, the external resistor should be a 24.9 kW ±1%. For phase
angle AC dimming with LYT4311-4318, the external resistor
should be a 49.9 kW ±1%. One percent resistors are
recommended as the resistor tolerance directly affects the
output tolerance. Other resistor values should not be used.
BYPASS Pin Capacitor Power Gain Selection
LYTSwitch-4 devices have the capability to tailor the internal
gain to either full or a reduced output power setting. This allows
selection of a larger device to minimize dissipation for both
thermal and efficiency reasons. The power gain is selected with
the value of the BYPASS pin capacitor. The full power setting is
selected with a 4.7 µF capacitor and the reduced power setting
(for higher efciency) is selected with a 47 µF capacitor. The
BYPASS pin capacitor sets both the internal power gain as well
as the over-current protection (OCP) threshold. Unlike the
larger devices, the LYT4x11 power gain is not programmable.
Use a 47 µF capacitor for the LYT4x11.
Switching Frequency
The switching frequency is 132 kHz during normal operation.
To further reduce the EMI level, the switching frequency is
jittered (frequency modulated) by approximately 2.6 kHz.
During start-up the frequency is 66 kHz to reduce start-up time
when the AC input is phase angle dimmed. Jitter is disabled in
deep dimming.
Soft-Start
The controller includes a soft-start timing feature which inhibits
the auto-restart protection feature for the soft-start period (tSOFT)
to distinguish start-up into a fault (short-circuit) from a large
output capacitor. At start-up the LYTSwitch-4 clamps the
maximum duty cycle to reduce the output power. The total
soft-start period is tSOFT.
Remote ON/OFF and EcoSmart
The VOLTAGE MONITOR pin has a 1 V threshold comparator
connected at its input. This voltage threshold is used for
remote ON/OFF control. When a signal is received at the
VOLTAGE MONITOR pin to disable the output (VOLTAGE
MONITOR pin tied to ground through an optocoupler photo-
transistor) the LYTSwitch-4 will complete its current switching
cycle before the internal power FET is forced off.
The remote ON/OFF feature can also be used as an eco-mode
or power switch to turn off the LYTSwitch-4 and keep it in a
very low power consumption state for indefinite long periods.
When the LYTSwitch-4 is remotely turned on after entering this
mode, it will initiate a normal start-up sequence with soft-start
the next time the BYPASS pin reaches 5.9 V. In the worst case,
the delay from remote on to start-up can be equal to the full
discharge/charge cycle time of the BYPASS pin. This reduced
consumption remote off mode can eliminate expensive and
unreliable in-line mechanical switches.
IFB(AR)
IFB(DCMAXR)
DC10 DCMAX
IFB(SKIP)
IFB
PI-5433-060410
Skip-Cycle
CC Control
Region
Soft-Start and
CC Fold-Back
Region
Auto-Restart
Maximum Duty Cycle
Rev. E 11/14
5
LYT4211-4218/4311-4318
www.power.com
Figure 7. Remote ON/OFF VOLTAGE MONITOR Pin Control.
5.9 V Regulator/Shunt Voltage Clamp
The internal 5.9 V regulator charges the bypass capacitor
connected to the BYPASS pin to 5.9 V by drawing a current
from the voltage on the DRAIN pin whenever the power FET is
off. The BYPASS pin is the internal supply voltage node. When
the power FET is on, the device operates from the energy stored
in the bypass capacitor. Extremely low power consumption of the
internal circuitry allows LYTSwitch-4 to operate continuously from
current it takes from the DRAIN pin. A bypass capacitor value
of 47 or 4.7 µF is sufcient for both high frequency decoupling
and energy storage. In addition, there is a 6.4 V shunt regulator
clamping the BYPASS pin at 6.4 V when current is provided to
the BYPASS pin through an external resistor. This facilitates
powering of LYTSwitch-4 externally through a bias winding to
increase operating efficiency. It is recommended that the
BYPASS pin is supplied current from the bias winding for
normal operation.
Auto-Restart
In the event of an open-loop fault (open FEEDBACK pin resistor
or broken path to feedback winding), output short-circuits or an
overload condition the controller enters into the auto-restart
mode. The controller annunciates both short-circuit and
open-loop conditions once the FEEDBACK pin current falls
below the IFB(AR) threshold after the soft-start period. To minimize
the power dissipation under this fault condition the shutdown/
auto-restart circuit turns the power supply on (same as the
soft-start period) and off at an auto-restart duty cycle of
typically DCAR for as long as the fault condition persists. If the
fault is removed during the auto-restart off-time, the power
supply will remain in auto-restart until the full off-time count is
completed. Special consideration must be made to appropriately
size the output capacitor to ensure that after the soft-start
period (tSOFT) the FEEDBACK pin current is above the IFB(AR)
threshold to ensure successful power-supply start-up. After the
soft-start time period, auto-restart is activated only when the
FEEDBACK pin current falls below IFB(AR).
Over-Current Protection
The current limit circuit senses the current in the power FET.
When this current exceeds the internal threshold (ILIMIT), the power
FET is turned off for the remainder of that cycle. A leading edge
blanking circuit inhibits the current limit comparator for a short
time (tLEB) after the power FET is turned on. This leading edge
blanking time has been set so that current spikes caused by
capacitance and rectifier reverse recovery will not cause
premature termination of the power FET conduction.
Line Overvoltage Protection
This device includes overvoltage detection to limit the maximum
operating voltage detected through the VOLTAGE MONITOR pin.
An external peak detector consisting of a diode and capacitor is
required to provide input line peak voltage to the VOLTAGE
MONITOR pin through a resistor.
The resistor sets line overvoltage (OV) shutdown threshold which,
once exceeded, forces the LYTSwitch-4 to stop switching. Once
the line voltage returns to normal, the device resumes normal
operation. A small amount of hysteresis is provided on the OV
threshold to prevent noise-generated toggling. When the power
FET is off, the rectified DC high voltage surge capability is
increased to the voltage rating of the power FET (725 V), due to the
absence of the reflected voltage and leakage spikes on the drain.
Hysteretic Thermal Shutdown
The thermal shutdown circuitry senses the controller die
temperature. The threshold is set at 142 °C typical with a 75 °C
hysteresis. When the die temperature rises above this threshold
(142 °C) the power FET is disabled and remains disabled until
the die temperature falls by 75 °C, at which point the power FET
is re-enabled.
Safe Operating Area (SOA) Protection
The device also features a safe operating area (SOA) protection
mode which disables FET switching for 40 cycles in the event
the peak switch current reaches the ILIMIT threshold and the switch
on-time is less than tON(SOA). This protection mode protects the
device under short-circuited LED conditions and at start-up during
the soft-start period when auto-restart protection is inhibited.
The SOA protection mode remains active in normal operation.
PI-5435-052510
D
S
BP
V
R FB
CONTROL
Rev. E 11/14
6
LYT4211-4218/4311-4318
www.power.com
Application Example
20 W TRIAC Dimmable High Power Factor LED Driver
Design Example (DER-350)
The circuit schematic in Figure 8 shows a TRIAC dimmable high
power factor LED driver based on LYT4317E from the LYTSwitch-4
family of devices. The design is configurable for non-dimmable
only applications by simple component value changes. It was
optimized to drive an LED string at a voltage of 36 V with a
constant current of 0.7 A ideal for Lumens PAR lamp retro-fit
applications. The design operates over an input voltage range
of 90 VAC to 132 VAC.
The key goals of this design were compatibility with standard
leading edge TRIAC AC dimmers, very wide dimming range
(1000:1, 550 mA:0.55 mA), high efficiency (>85%) and high
power factor (>0.9). The design is fully protected from faults
such as no-load (open load), overvoltage and output short-
circuit or overload conditions and over temperature.
Circuit Description
The LYTSwitch-4 device (U1- LYT4317E) integrates the power
FET, controller and start-up functions into a single package
reducing the component count versus typical implementations.
Configured as part of an isolated continuous conduction mode
flyback converter, U1 provides high power factor via its internal
control algorithm together with the small input capacitance of
the design. Continuous conduction mode operation results in
reduced primary peak and RMS current. This both reduces
EMI noise, allowing simpler, smaller EMI filtering components
and improves efciency. Output current regulation is maintained
without the need for secondary-side sensing which eliminates
current sense resistors and improves efficiency.
Input Stage
Fuse F1 provides protection from component failures while RV1
provides a clamp during differential line surges, keeping the
peak drain voltage of U1 below the 725 V rating of the internal
power FET. Bridge rectifier BR1 rectifies the AC line voltage.
EMI filtering is provided by L1-L3, C1, C4, R2, R24 and R25
together with the safety rated Y class capacitor (CY1) that bridges
the safety isolation barrier between primary and secondary.
Resistor R2, R24 and R25 act to damp any resonances formed
between L1, L2, L3, C1 and the AC line impedance. A small
bulk capacitor (C4) is required to provide a low impedance
source for the primary switching current. The maximum value
of C2 and C4 is limited in order to maintain a power factor of
greater than 0.9.
LYTSwitch-4 Primary
To provide peak line voltage information to U1 the incoming
rectified AC peak charges C6 via D2. This is then fed into the
VOLTAGE MONITOR pin of U1 as a current via R10. This
sensed current is also used by the device to set the line input
overvoltage protection threshold. Resistor R9 provides a
discharge path for C6 with a time constant much longer than
that of the rectified AC to prevent generation of line frequency
ripple.
The VOLTAGE MONITOR pin current and the FEEDBACK pin
current are used internally to control the average output LED
current. For TRIAC phase-dimming applications a 49.9 kW
resistor (R14) is used on the REFERENCE pin and 2 MW (R10)
on the VOLTAGE MONITOR pin to provide a linear relationship
between input voltage and the output current and maximizing
the dimming range.
Diode D3, R15 and C7 clamp the drain voltage to a safe level
due to the effects of leakage inductance. Diode D4 is
necessary to prevent reverse current from flowing through U1
for the period of the rectified AC input voltage that the voltage
across C4 falls to below the reflected output voltage (VOR).
R6
360 k
PI-6875-052213
D
S
BP
V
R FB
CONTROL
FL1
T1
RM8
12
1 FL2
10
11
R10
2 M
1%
R15
200 k
R9
510 k
1/8 W
R24
47 k
1/8 W
R1
510
1/2 W
R25
47 k
1/8 W
R2
47 k
1/8 W
L1
1 mH
L2
1 mH
R14
49.9 k
1%
1/16 W
R18
165 k
1%
1/16 W
R23
20 k
36 V,
550 mA
90 - 132
VAC
RTN
L N
R19
20 k
1/8 W
C5
100 nF
50 V
R26
30
R20
39
1/8 W
R17
3 k
1/10 W
R27
10
1/10 W
D2
DFLU1400
C7
2.2 nF
630 V
D3
US1J
D5
BAV16
VR4
MAZS3300ML
33 V
Q2
MMBT3904
D8
BAV21
Q1
X0202MA2BL2
D6
BAV21
D7
BYW29-200
D4
US1D
R22
1 k
1/10 W
BR1
MB6S
600 V
RV1
140 VAC
F1
5 A
C11
330 µF
63 V
100 pF
200 V
CY1
470 pF
250 VAC
C12
330 µF
63 V
C8
47 µF
16 V
C15
100 nF
50 V
C14
10 nF
50 V
C9
56 µF
50 V
LYTSwitch-4
U1
LYT4317E
C6
2.2 µF
250 V
C1
220 nF
250 V
C4
100 nF
250 V
L3
5 mH
R8
100
1 W
C3
470 nF
50 V
C2
100 nF
250 V
D9
DFLU1400-7
Figure 8. DER-350 Schematic of an Isolated, TRIAC Dimmable, High Power Factor, 90-132 VAC, 20 W / 36 V / 550 mA LED Driver.
Rev. E 11/14
7
LYT4211-4218/4311-4318
www.power.com
Diode D6, C5, C9, R19 and R20 create the primary bias supply
from an auxiliary winding on the transformer. Capacitor C8
provides local decoupling for the BYPASS pin of U1 which is the
supply pin for the internal controller. During start-up C8 is
charged to ~6 V from an internal high-voltage current source
tied to the device DRAIN pin. This allows the part to start
switching at which point the operating supply current is provided
from the bias supply via R17. Capacitor C8 also selects the
output power mode (47 µF for reduced power was selected to
reduce dissipation in U1 and increase efficiency for this design).
Feedback
The bias winding voltage is proportional to the output voltage
(set by the turns ratio between the bias and secondary
windings). This allows the output voltage to be monitored
without secondary-side feedback components. Resistor R18
converts the bias voltage into a current which is fed into the
FEEDBACK pin of U1. The internal engine within U1 combines
the FEEDBACK pin current, the VOLTAGE MONITOR pin current
and drain current information to provide a constant output
current over a 1.5:1 output voltage variation (LED string voltage
variation of ±25%) at a fixed line input voltage.
To limit the output voltage at no-load an output overvoltage
protection circuit is set by D8, C15, R22, VR4, R27, C14 and Q2.
Should the output load be disconnected then the bias voltage
will increase until VR4 conducts, turning on Q2 and reducing
the current into the FEEDBACK pin. When this current drops
below 10 µA the part enters auto-restart and switching is
disabled for 300 ms allowing time for the output and bias
voltages to fall.
Output Rectification
The transformer secondary winding is rectified by D7 and
filtered by C11 and C12. An ultrafast TO-220 diode was
selected for efficiency and the combined value of C11 and C12
were selected to give peak-to-peak LED ripple current equal to
30% of the mean value. For designs where lower ripple is
desirable the output capacitance value can be increased.
A small pre-load is provided by R23 which discharges residual
charge in output capacitors when turned off.
TRIAC Phase Dimming Control Compatibility
The requirement to provide output dimming with low-cost,
TRIAC-based, leading edge phase dimmers introduces a
number of trade-offs in the design.
Due to the much lower power consumed by LED based lighting
the current drawn by the overall lamp is below the holding
current of the TRIAC within the dimmer. This can cause
undesirable behaviors such as limited dimming range and/or
flickering as the TRIAC fires inconsistently. The relatively large
impedance the LED lamp presents to the line allows significant
ringing to occur due to the inrush current charging the input
capacitance when the TRIAC turns on. This too can cause
similar undesirable behavior as the ringing may cause the
TRIAC current to fall to zero and turn off.
To overcome these issues simple two circuits, the SCR active
damper and R-C passive bleeder, are incorporated. The
drawback of these circuits is increased dissipation and
therefore reduced efficiency of the supply. For non-dimming
applications these components can simply be omitted.
The SCR active damper consists of components R6, C3, and
Q1 in conjunction with R8. This circuit limits the inrush current
that flows to charge C4 when the TRIAC turns on by placing R8
in series for the first ~1 ms of the TRIAC conduction. After
approximately 1 ms, Q1 turns on and bypasses R8. This keeps
the power dissipation on R8 low and allows a larger value
during current limiting. Resistor R6 and C3 provide the delay
on Q1 turn on after the TRIAC conducts. Diode D9 blocks the
charge in capacitor C4 from flowing back after the TRIAC turns
on which helps in dimming compatibility especially with high
power dimmers.
The passive bleeder circuit is comprised of R1 and C1. This
helps keep the input current above the TRIAC holding current
while the input current corresponding to the effective driver
resistance increases during each AC half-cycle.
Rev. E 11/14
8
LYT4211-4218/4311-4318
www.power.com
Modified DER-350 20 W High Power Factor LED Driver
for Non-Dimmable and Enhanced Line Regulation
The circuit schematic in Figure 9 shows a high power factor
LED driver based on a LYT4317 from the LYTSwitch-4 family of
devices. It was optimized to drive an LED string at a voltage of
36 V with a constant current of 0.55 A, ideal for high lumen PAR
lamp retro-fit applications. The design operates over the
low-line input voltage range of 90 VAC to 132 VAC and is
non-dimming application. A non-dimming application has
tighter output current variation with changes in the line voltage
than a dimming application. It’s key to note that, although not
specified for dimming, no circuit damage will result if the end
user does operate the design with a phase controlled dimmer.
Modification for Non-Dimmable Configuration
The design is configurable for non-dimmable application by
simply removing the component for SCR active damper (R6,
R8, C3, and Q1), blocking diode D9 and R-C bleeder (R1, C1)
changes and replacing the reference resistor R14 with 24.9 kW.
(See Figure 9)
Key Application Considerations
Power Table
The data sheet power table (Table 1) represents the minimum
and maximum practical continuous output power based on the
following conditions:
Efficiency of 80%
Device local ambient of 70 °C
Sufficient heat sinking to keep the device temperature below
100 °C
For minimum output power column
Reflected output voltage (VOR) of 120 V
FEEDBACK pin current of 135 µA
BYPASS pin capacitor value of 47 µF
For maximum output power column
Reflected output voltage (VOR) of 65 V
FEEDBACK pin current of 165 µA
BYPASS pin capacitor value of 4.7 µF (LYT4x11 = 4.7 µF)
Note that input line voltages above 85 VAC do not change the
power delivery capability of LYTSwitch-4 devices.
Device Selection
Select the device size by comparing the required output power
to the values in Table 1. For thermally challenging designs, e.g.,
incandescent lamp replacement, where either the ambient
temperature local to the LYTSwitch-4 device is high and/or
there is minimal space for heat sinking use the minimum output
power column. This is selected by using a 47 µF BYPASS pin
capacitor and results in a lower device current limit and therefore
lower conduction losses. For open frame design or designs
where space is available for heat sinking then refer to the
maximum output power column. This is selected by using a
4.7 µF BYPASS pin capacitor for all but the LYT4x11 which has
only one power setting. In all cases in order to obtain the best
output current tolerance maintain the device temperature below
100 °C
Maximum Input Capacitance
To achieve high power factor, the capacitance used in both the
EMI filter and for decoupling the rectified AC (bulk capacitor)
must be limited in value. The maximum value is a function of
the output power of the design and reduces as the output
power reduces. For the majority of designs limit the total
capacitance to less than 200 nF with a bulk capacitor value of
100 nF. Film capacitors are recommended compared to
ceramic types as they minimize audible noise with operating
with leading edge phase dimmers. Start with a value of 10 nF
for the capacitance in the EMI filter and increase in value until
there is sufficient EMI margin.
PI-6875a-052213
D
S
BP
V
R FB
CONTROL
FL1
T1
RM8
12
1 FL2
10
11
R10
2 M
1%
R15
200 k
R9
510 k
1/8 W
R24
47 k
1/8 W
R25
47 k
1/8 W
R2
47 k
1/8 W
L1
1 mH
L2
1 mH
R14
24.9 k
1%
1/16 W
R18
165 k
1%
1/16 W
R23
20 k
36 V,
550 mA
90 - 132
VAC
RTN
L N
R19
20 k
1/8 W
C5
100 nF
50 V
R26
30
R20
39
1/8 W
R17
3 k
1/10 W
R27
10
1/10 W
D2
DFLU1400
C7
2.2 nF
630 V
D3
US1J
D5
BAV16
VR4
MAZS3300ML
33 V
Q2
MMBT3904
D8
BAV21
D6
BAV21
D7
BYW29-200
D4
US1D
R22
1 k
1/10 W
BR1
MB6S
600 V
RV1
140 VAC
F1
5 A
C11
330 µF
63 V
C13
100 pF
200 V
CY1
470 pF
250 VAC
C12
330 µF
63 V
C8
47 µF
16 V
C15
100 nF
50 V
C14
10 nF
50 V
C9
56 µF
50 V
LYTSwitch-4
U1
LYT4317E
C6
2.2 µF
250 V
C4
100 nF
250 V
L3
5 mH
C2
100 nF
250 V
Figure 9. Modified Schematic of RD-350 for Non-Dimmable, Isolated, High Power Factor, 90-132 VAC, 20 W / 36 V LED Driver.
Rev. E 11/14
9
LYT4211-4218/4311-4318
www.power.com
REFERENCE Pin Resistance Value Selection
The LYTSwitch-4 family contains phase dimming devices,
LYT4311-4318, and non-dimming devices, LYT4211-4218. The
non-dimmable devices use a 24.9 kW ±1% REFERENCE pin
resistor for best output current tolerance (over AC input voltage
changes). The dimmable devices (i.e. LYT4311-4318) use 49.9 kW
±1% to achieve the widest dimming range.
VOLTAGE MONITOR Pin Resistance Network Selection
For widest AC phase angle dimming range with LYT4311-4318,
use a 2 MW (1.7 MW for 100 VAC (Japan)) resistor connected to
the line voltage peak detector circuit. Make sure that the
resistor’s voltage rating is sufficient for the peak line voltage. If
necessary use multiple series connected resistors.
Primary Clamp and Output Reflected Voltage VOR
A primary clamp is necessary to limit the peak drain to source
voltage. A Zener clamp requires the fewest components and
board space and gives the highest efficiency. RCD clamps are
also acceptable however the peak drain voltage should be
carefully verified during start-up and output short-circuits as the
clamping voltage varies with significantly with the peak drain
current.
For the highest efficiency, the clamping voltage should be
selected to be at least 1.5 times the output reflected voltage,
VOR, as this keeps the leakage spike conduction time short.
This will ensure efficient operation of the clamp circuit and will
also keep the maximum drain voltage below the rated
breakdown voltage of the FET. An RCD (or RCDZ) clamp
provides tighter clamp voltage tolerance than a Zener clamp.
The RCD clamp is more cost effective than the Zener clamp but
requires more careful design to ensure that the maximum drain
voltage does not exceed the power FET breakdown voltage.
These VOR limits are based on the BVDSS rating of the internal
FET, a VOR of 60 V to 100 V is typical for most designs, giving
the best PFC and regulation performance.
Series Drain Diode
An ultrafast or Schottky diode in series with the drain is
necessary to prevent reverse current flowing through the
device. The voltage rating must exceed the output reflected
voltage, VOR. The current rating should exceed two times the
average primary current and have a peak rating equal to the
maximum drain current of the selected LYTSwitch-4 device.
Line Voltage Peak Detector Circuit
LYTSwitch-4 devices use the peak line voltage to regulate the
power delivery to the output. A capacitor value of 1 µF to 4.7 µF
is recommended to minimize line ripple and give the highest
power factor (>0.9), smaller values are acceptable but result in
lower PF and higher line current distortion.
Operation with Phase Controlled Dimmers
Dimmer switches control incandescent lamp brightness by not
conducting (blanking) for a portion of the AC voltage sine wave.
This reduces the RMS voltage applied to the lamp thus reducing
the brightness. This is called natural dimming and the LYTSwitch-4
LYT4311-4318 devices when configured for dimming utilize
natural dimming by reducing the LED current as the RMS line
voltage decreases. By this nature, line regulation performance is
purposely decreased to increase the dimming range and more
closely mimic the operation of an incandescent lamp. Using a
49.9 kW REFERENCE pin resistance selects natural dimming
mode operation.
Leading Edge Phase Controlled Dimmers
The requirement to provide flicker-free output dimming with low-
cost, TRIAC-based, leading edge phase dimmers introduces a
number of trade-offs in the design.
Due to the much lower power consumed by LED based lighting
the current drawn by the overall lamp is below the holding
current of the TRIAC within the dimmer. This causes
undesirable behaviors such as limited dimming range and/or
flickering. The relatively large impedance the LED lamp presents
to the line allows significant ringing to occur due to the inrush
current charging the input capacitance when the TRIAC turns
on. This too can cause similar undesirable behavior as the
ringing may cause the TRIAC current to fall to zero and turn off.
To overcome these issues two circuits, the active damper and
passive bleeder, are incorporated. The drawback of these
circuits is increased dissipation and therefore reduced efficiency
of the supply so for non-dimming applications these components
can simply be omitted.
Figure 10a shows the line voltage and current at the input of a
leading edge TRIAC dimmer with Figure 10b showing the
resultant rectified bus voltage. In this example, the TRIAC
conducts at 90 degrees.
50 100 150 200 250 300 350 400
Conduction Angle (°)
Line Voltage (at Dimmer Input) (V)
Line Current (Through Dimmer) (A)
350
250
150
50
-50
-150
-250
-350
0.35
0.25
0.15
0.05
-0.05
-0.15
-0.25
-0.35
PI-5983-060810
Voltage
Current
0.5
Figure 10a. Ideal Input Voltage and Current Waveform for a Leading Edge
TRIAC Dimmer at 90°.
Rev. E 11/14
10
LYT4211-4218/4311-4318
www.power.com
050 100 150 200 250 400350300
Conduction Angle (°)
Rectified Input Voltage (V)
Rectified Input Current (A)
350
300
250
200
150
100
50
0
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
PI-5984-060810
Voltage
Current
Figure 10b. Resultant Waveforms Following Rectification of TRIAC Dimmer Output.Figure 12. Ideal Dimmer Output Voltage and Current Waveforms for a Trailing
Edge Dimmer at 90° Conduction Angle.
Figure 11. Example of Phase Angle Dimmer Showing Erratic Firing.
Figure 11 shows undesired rectified bus voltage and current
with the TRIAC turning off prematurely and restarting.
If the TRIAC is turning off before the end of the half-cycle
erratically or alternate half AC cycles have different conduction
angles then flicker will be observed in the LED light due to
variations in the output current. This can be solved by including
a bleeder and damper circuit.
Dimmers will behave differently based on manufacturer and
power rating, for example a 300 W dimmer requires less
dampening and requires less power loss in the bleeder than a
600 W or 1000 W dimmer due to different drive circuits and
TRIAC holding current specifications. Multiple lamps in parallel
driven from the same dimmer can introduce more ringing due to
the increased capacitance of parallel units. Therefore, when
testing dimmer operation verify on a number of models,
different line voltages and with both a single driver and multiple
drivers in parallel.
Start by adding a bleeder circuit. Add a 0.44 µF capacitor and
510 W 1 W resistor (components in series) across the rectified
bus (C1 and R1 in Figure 8). If the results in satisfactory operation
reduce the capacitor value to the smallest that result in acceptable
performance to reduce losses and increase efficiency.
If the bleeder circuit does not maintain conduction in the TRIAC,
then add an active damper as shown in Figure 8. This consists
of components R6, C3, and Q1 in conjunction with R8. This
circuit limits the inrush current that flows to charge C4 when the
TRIAC turns on by placing R8 in series for the first 1 ms of the
TRIAC conduction. After approximately 1 ms, Q1 turns on and
shorts R8. This keeps the power dissipation on R8 low and
allows a larger value to be used during current limiting.
Increasing the delay before Q1 turns on by increasing the value
of resistor R6 will improve dimmer compatibility but cause more
power to be dissipated across R8. Monitor the AC line current
and voltage at the input of the power supply as you make the
adjustments. Increase the delay until the TRIAC operates
properly but keep the delay as short as possible for efficiency.
As a general rule the greater the power dissipated in the bleeder
and damper circuits, the more types of dimmers will work with
the driver.
Trailing Edge Phase Controlled Dimmers
Figure 11 shows the line voltage and current at the input of the
power supply with a trailing edge dimmer. In this example, the
dimmer conducts at 90 degrees. Many of these dimmers use
back-to-back connected power FETs rather than a TRIAC to
control the load. This eliminates the holding current issue of
TRIACs and since the conduction begins at the zero crossing,
high current surges and line ringing are minimized. Typically these
types of dimmers do not require damping and bleeder circuits.
050 100 150 200 250 400350300
Conduction Angle (°)
Rectified Input Voltage (V)
Rectified Input Current (A)
350
300
250
200
150
100
50
0
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
PI-5985-060810
Voltage
Current
50 100 150 200 250 300 350
Conduction Angle (°)
Dimmer Output Voltage (V)
Dimmer Output Current (A)
350
250
150
50
-50
-150
-250
-350
0.35
0.25
0.15
0.05
-0.05
-0.15
-0.25
-0.35
PI-5986-060810
Voltage
Current
0
Rev. E 11/14
11
LYT4211-4218/4311-4318
www.power.com
Audible Noise Considerations for Use with
Leading Edge Dimmers
Noise created when dimming is typically created by the input
capacitors, EMI filter inductors and the transformer. The input
capacitors and inductors experience high di/dt and dv/dt every
AC half-cycle as the TRIAC fires and an inrush current flows to
charge the input capacitance. Noise can be minimized by
selecting film vs. ceramic capacitors, minimizing the capacitor
value and selecting inductors that are physically short and wide.
The transformer may also create noise which can be minimized
by avoiding cores with long narrow legs (high mechanical
resonant frequency). For example, RM cores produce less
audible noise than EE cores for the same flux density. Reducing
the core flux density will also reduce the noise. Reducing the
maximum flux density (BM) to 1500 Gauss usually eliminates
any audible noise but must be balanced with the increased core
size needed for a given output power.
Thermal and Lifetime Considerations
Lighting applications present thermal challenges to the driver.
In many cases the LED load dissipation determines the working
ambient temperature experienced by the drive so thermal
evaluation should be performed with the driver inside the final
enclosure. Temperature has a direct impact on driver and LED
lifetime. For every 10 °C rise in temperature, component life is
reduced by a factor of 2. Therefore it is important to properly
heat sink and to verify the operating temperatures of all devices.
Layout Considerations
Primary-Side Connections
Use a single point (Kelvin) connection at the negative terminal of
the input filter capacitor for the SOURCE pin and bias returns.
This improves surge capabilities by returning surge currents
from the bias winding directly to the input filter capacitor. The
BYPASS pin capacitor should be located as close to the
BYPASS pin and connected as close to the SOURCE pin as
possible. The SOURCE pin trace should not be shared with the
main power FET switching currents. All FEEDBACK pin
components that connect to the SOURCE pin should follow the
same rules as the BYPASS pin capacitor. It is critical that the
main power FET switching currents return to the bulk capacitor
with the shortest path as possible. Long high current paths
create excessive conducted and radiated noise.
Secondary-Side Connections
The output rectifier and output filter capacitor should be as
close as possible. The transformer’s output return pin should
have a short trace to the return side of the output filter capacitor.
Figure 13. DER-350 20 W Layout Example, Top Silk / Bottom Layer.
PI-6904-072313
Output
Capacitors
VOLTAGE MONITOR Pin
Resistor
FEEDBACK Pin
Resistor
REFERENCE Pin
Resistor
Input EMI Filter
LYT4317E
Bullk
Capacitor
Clamp Transformer Output
Diode
Output
Capacitor
BYPASS Pin
Capacitor
Rev. E 11/14
12
LYT4211-4218/4311-4318
www.power.com
Quick Design Checklist
Maximum Drain Voltage
Verify that the peak VDS does not exceed 725 V under all
operating conditions including start-up and fault conditions.
Maximum Drain Current
Measure the peak drain current under all operation conditions
including start-up and fault conditions. Look for signs of
transformer saturation (usually occurs at highest operating
ambient temperatures). Verify that the peak current is less than
the stated Absolute Maximum Rating in the data sheet.
Thermal Check
At maximum output power, both minimum and maximum line
voltage and ambient temperature; verify that temperature
specifications are not exceeded for the LYTSwitch-4,
transformer, output diodes, output capacitors and drain clamp
components.
Rev. E 11/14
13
LYT4211-4218/4311-4318
www.power.com
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
Control Functions
Switching Frequency fOSC TJ = 65 °C
Average 124 132 140
kHz
Peak-Peak Jitter 5.4
Frequency Jitter
Modulation Rate fM
TJ = 65 °C
See Note B 2.6 kHz
BYPASS Pin
Charge Current
ICH1
VBP = 0 V,
TJ = 65 °C
LYT4x11 -4.1 -3.4 -2.7
mA
LYT4x12 -7.3 -6.1 -4.9
LYT4x13-4x17 -12 -9.5 -7.0
LYT4x18 -13.3 -10.8 -8.3
ICH2
VBP = 5 V,
TJ = 65 °C
LYT4x11 -0.85 -0.62 -0.43
LYT4x12 -3.5 -2.4 -1.7
LYT4x13-4x17 -6.5 -4.35 -3.1
LYT4x18 -7.5 -5.5 -4.25
Charging Current
Temperature Drift See Note A, B 0.7 %/°C
BYPASS Pin Voltage VBP 0 °C < TJ < 100 °C 5.75 5.95 6.15 V
BYPASS Pin
Voltage Hysteresis VBP(H) 0 °C < TJ < 100 °C 0.85 V
BYPASS Pin
Shunt Voltage VBP(SHUNT)
IBP = 4 mA
0 °C < TJ < 100 °C 6.1 6.4 6.6 V
Soft-Start Time tSOFT
TJ = 65 °C
VBP = 5.9 V 55 76 ms
Absolute Maximum Ratings(1,4)
DRAIN Pin Peak Current(5): LY T4x11 .................................1.37 A
LY T4x12 .................................2.08 A
LY T4x13 .................................2.72 A
LY T4x14 ................................ 4.08 A
LY T4x15 ................................ 5.44 A
LY T4x16 ................................ 6.88 A
LY T4x17 ................................. 7.7 3 A
LY T4x18 ................................ 9.00 A
DRAIN Pin Voltage ……………………… ................. -0.3 to 725 V
BYPASS Pin Voltage ................................................. -0.3 to 9 V
BYPASS Pin Current ……………………… ...................... 100 mA
VOLTAGE MONITOR Pin Voltage .............................-0.3 to 9 V(6)
FEEDBACK Pin Voltage ….. .................................. -0.3 to 9 V
REFERENCE Pin Voltage .......................................... -0.3 to 9 V
Lead Temperature(3) ........................................................260 °C
Storage Temperature …………………. .................. -65 to 150 °C
Operating Junction Temperature(2) .........................-40 to 150 °C
Notes:
1. All voltages referenced to SOURCE, TA = 65 °C.
2. Normally limited by internal circuitry.
3. 1/16 in. from case for 5 seconds.
4. Absolute Maximum Ratings specified may be applied, one
at a time without causing permanent damage to the
product. Exposure to Absolute Maximum Ratings for
extended periods of time may affect product reliability.
5. Peak DRAIN current is allowed while the DRAIN voltage is
simultaneously less than 400 V. See also Figure 13.
6. During start-up (the period before the BYPASS pin begins
powering the IC) the VOLTAGE MONITOR pin voltage can
safely rise to 15 V without damage.
Thermal Resistance
Thermal Resistance: E Package
(qJA) ....................................................105 °C/W(1)
(qJC) .................................................... 2 °C/W(2)
Notes:
1. Free standing with no heat sink.
2. Measured at back surface tab.
Rev. E 11/14
14
LYT4211-4218/4311-4318
www.power.com
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
Control Functions (cont.)
Drain Supply Current
ICD2
0 °C < TJ < 100 °C
FET Not Switching 0.5 0.8 1.2
mA
ICD1
0 °C < TJ < 100 °C
FET Switching at fOSC
1 2.5 4
VOLTAGE MONITOR Pin
Line Overvoltage
Threshold IOV
TJ = 65 °C
RR = 24.9 kW
RR = 49.9 kW
Threshold 115 123 131
µA
Hysteresis 6
VOLTAGE MONITOR
Pin Voltage VV
0 °C < TJ < 100 °C
IV < IOV
2.75 3.0 3.25 V
VOLTAGE MONITOR Pin
Short-Circuit Current IV(SC)
VV = 5 V
TJ = 65 °C 165 185 205 µA
Remote ON/OFF
Threshold VV(REM) TJ = 65 °C 0.5 V
FEEDBACK Pin
FEEDBACK Pin Current
at Onset of Maximum
Duty Cycle
IFB(DCMAXR) 0 °C < TJ < 100 °C 90 µA
FEEDBACK Pin Current
Skip Cycle Threshold IFB(SKIP) 0 °C < TJ < 100 °C 210 µA
Maximum Duty Cycle DCMAX
IFB(DCMAXR) < IFB < IFB(SKIP)
0 °C < TJ < 100 °C 90 99.9 %
FEEDBACK Pin Voltage VFB
IFB = 150 µA
0 °C < TJ < 100 °C 2.1 2.3 2.56 V
FEEDBACK Pin
Short-Circuit Current IFB(SC)
VFB = 5 V
TJ = 65 °C 320 400 480 µA
Duty Cycle Reduction
DC10 IFB = IFB(AR), TJ = 65 °C, See Note B 17
%DC40 IFB = 40 µA, TJ = 65 °C 34
DC60 IFB = 60 µA, TJ = 65 °C 55
Auto-Restart
Auto-Restart ON-Time tAR
TJ = 65 °C
VBP = 5.9 V 55 76 ms
Auto-Restart
Duty Cycle DCAR
TJ = 65 °C
See Note B 25 %
SOA Minimum Switch
ON-Time tON(SOA)
TJ = 65 °C
See Note B 0.875 µs
FEEDBACK Pin Current
During Auto-Restart IFB(AR) 0 °C < TJ < 100 °C 6.5 10 µA
Rev. E 11/14
15
LYT4211-4218/4311-4318
www.power.com
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
REFERENCE Pin
REFERENCE Pin
Voltage VRRR = 24.9 kW
0 °C < TJ < 100 °C
1.223 1.245 1.273 V
REFERENCE Pin
Current IR48.69 49.94 51.19 µA
Current Limit/Circuit Protection
Full Power
Current Limit
(CBP = 4.7 µF)
ILIMIT(F)
TJ = 65 °C
di/dt = 174 mA/µs LYT4x12 1.00 1.17
A
di/dt = 174 mA/µs LYT4x13 1.24 1.44
di/dt = 225 mA/µs LYT4x14 1.46 1.70
di/dt = 320 mA/µs LYT4x15 1.76 2.04
di/dt = 350 mA/µs LYT4x16 2.43 2.83
di/dt = 426 mA/µs LYT4x17 3.26 3.79
Reduced Power
Current Limit
(CBP = 47 µF)
ILIMIT(R)
TJ = 65 °C
di/dt = 133 mA/µs LYT4x11 0.74 0.86
A
di/dt = 195 mA/µs LYT4x12 0.81 0.95
di/dt = 192 mA/µs LYT4x13 1.00 1.16
di/dt = 240 mA/µs LYT4x14 1.19 1.38
di/dt = 335 mA/µs LYT4x15 1.43 1.66
di/dt = 380 mA/µs LYT4x16 1.76 2.05
di/dt = 483 mA/µs LYT4x17 2.35 2.73
di/dt = 930 mA/µs LYT4x18 4.90 5.70
Minimum ON-Time
Pulse tLEB + tIL(D) TJ = 65 °C 300 500 700 ns
Leading Edge
Blanking Time tLEB
TJ = 65 °C
See Note B 150 500 ns
Current Limit Delay tIL(D)
TJ = 65 °C
See Note B 150 ns
Thermal Shutdown
Temperature See Note B 147 155 164 °C
Thermal Shutdown
Hysteresis See Note B 56 °C
BYPASS Pin Power-Up
Reset Threshold
Voltage
VBP(RESET) 0 °C < TJ < 100 °C 2.25 3.30 4.25 V
Rev. E 11/14
16
LYT4211-4218/4311-4318
www.power.com
NOTES:
A. For specifications with negative values, a negative temperature coefficient corresponds to an increase in magnitude with increasing
temperature and a positive temperature coefficient corresponds to a decrease in magnitude with increasing temperature.
B. Guaranteed by characterization. Not tested in production.
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
Output
ON-State Resistance RDS(ON)
LYT4x11
ID = 100 mA
TJ = 65 °C 11.5 13.2
W
TJ = 100 °C 13.5 15.5
LYT4x12
ID = 100 mA
TJ = 65 °C 6.9 8.0
TJ = 100 °C 8.4 9.7
LYT4x13
ID = 150 mA
TJ = 65 °C 5.3 6.0
TJ = 100 °C 6.3 7.3
LYT4x14
ID = 150 mA
TJ = 65 °C 3.4 3.9
TJ = 100 °C 3.9 4.5
LYT4x15
ID = 200 mA
TJ = 65 °C 2.5 2.9
TJ = 100 °C 3.0 3.4
LYT4x16
ID = 250 mA
TJ = 65 °C 1.9 2.2
TJ = 100 °C 2.3 2.7
LYT4x17
ID = 350 mA
TJ = 65 °C 1.7 2.0
TJ = 100 °C 2.0 2.4
LYT4x18
ID = 600 mA
TJ = 65 °C 1.3 1.5
TJ = 100 °C 1.6 1.8
OFF-State Drain
Leakage Current IDSS
VBP = 6.4 V
VDS = 560 V
TJ = 100 °C
50 µA
Breakdown Voltage BVDSS
VBP = 6.4 V
TJ = 65 °C 725 V
Minimum Drain
Supply Voltage TJ < 100 °C 36 V
Rise Time tRMeasured in a Typical Flyback
See Note B
100 V
Fall Time tF50 ns
Rev. E 11/14
17
LYT4211-4218/4311-4318
www.power.com
Typical Performance Characteristics
Figure 14. Drain Capacitance vs. Drain Pin Voltage. Figure 15. Power vs. Drain Voltage.
Figure 16. Drain Current vs. Drain Voltage. Figure 17. Maximum Allowable Drain Current vs. Drain Voltage.
1 100 200 300 400 500 600
10
100
1000
10000
PI-6715-072313
DRAIN Pin Voltage (V)
DRAIN Capacitance (pF)
LYT4x11 0.18
LYT4x12 0.28
LYT4x13 0.38
LYT4x14 0.56
LYT4x15 0.75
LYT4x16 1.00
LYT4x17 1.16
LYT4x18 1.55
Scaling Factors:
300
100
200
0
0 200100 400 500 600300 700
DRAIN Voltage (V)
Power (mW)
PI-6716-071012
LYT4x11 0.18
LYT4x12 0.28
LYT4x13 0.38
LYT4x14 0.56
LYT4x15 0.75
LYT4x16 1.00
LYT4x17 1.16
LYT4x18 1.55
Scaling Factors:
0
02 4 6 8 10 12 14 16 18 20
DRAIN Voltage (V)
DRAIN Current (A)
PI-6717-071012
2
3
1
LYT4x28 TCASE = 25 °C
LYT4x28 TCASE = 100 °C
4
5
LYT4x11 0.18
LYT4x12 0.28
LYT4x13 0.38
LYT4x14 0.56
LYT4x15 0.75
LYT4x16 1.00
LYT4x17 1.16
LYT4x18 1.55
Scaling Factors:
0
0100 200 300 400 600500 700 800
DRAIN Voltage (V)
DRAIN Current
(Normalized to Absolute Maximum Rating)
PI-6909-110512
0.6
0.8
0.4
0.2
1
1.2
Rev. E 11/14
18
LYT4211-4218/4311-4318
www.power.com
PI-4917-020515
MOUNTING HOLE PATTERN
(not to scale)
PIN 7
PIN 1
0.100 (2.54) 0.100 (2.54)
0.059 (1.50)
0.059 (1.50)
0.050 (1.27)
0.050 (1.27)
0.100 (2.54)
0.155 (3.93)
0.020 (0.50)
Notes:
1. Dimensioning and tolerancing per ASME Y14.5M-1994.
2. Dimensions noted are determined at the outermost extremes of the plastic
body exclusive of mold flash, tie bar burrs, gate burrs, and interlead flash, but
including any mismatch between the top and bottom of the plastic body.
Maximum mold protrusion is 0.007 [0.18] per side.
3. Dimensions noted are inclusive of plating thickness.
4. Does not include inter-lead flash or protrusions.
5. Controlling dimensions in inches (mm).
0.403 (10.24)
0.397 (10.08)
0.325 (8.25)
0.320 (8.13)
0.050 (1.27)
FRONT VIEW
2
2
B
A
0.070 (1.78) Ref.
Pin #1
I.D.
3
C
0.016 (0.41)
Ref.
0.290 (7.37)
Ref.
0.047 (1.19)
0.100 (2.54)
0.519 (13.18)
Ref.
0.198 (5.04) Ref.
0.264 (6.70)
Ref.
0.118 (3.00)
3
0.140 (3.56)
0.120 (3.05)
0.021 (0.53)
0.019 (0.48)
0.378 (9.60)
Ref. 0.019 (0.48) Ref.
0.060 (1.52)
Ref.
0.048 (1.22)
0.046 (1.17)
0.081 (2.06)
0.077 (1.96)
0.207 (5.26)
0.187 (4.75)
0.033 (0.84)
0.028 (0.71)
0.016 (0.41)
0.011 (0.28)
eSIP-7C (E Package)
10° Ref.
All Around
0.020 M 0.51 M C
0.010 M 0.25 M C A B
SIDE VIEW
END VIEW
BACK VIEW
4
0.023 (0.58)
0.027 (0.70)
DETAIL A
Detail A
Part Ordering Information
• LYTSwitch-4 Product Family
• 4 Series Number
• PFC/Dimming
2 PFC No Dimming
3 PFC Dimming
• Voltage Range
1 Low-Line
• Device Size
• Package Identifier
E eSIP-7C
LYT 4 2 1 3 E
Rev. E 11/14
19
LYT4211-4218/4311-4318
www.power.com
Revision Notes Date
A Initial Release. 11/12
B Corrected Min and Typ parameter table values on pages 13 and 14. 02/13
B Updated parameters ICH1, ICH2, ICD1, DCAR, ILIMIT(F), ILIMIT(R), on pages 13, 14 and 15. 02/20/13
C Updated figures 1, 3a, 3b, 3c, 3d, 8, 9 and 13. 06/13
D Added Note 6 to Absolute Maximum Ratings section. 10/13
E Removed L pin parts, updated ICH2, BVDSS, Thermal Shutdown Temperature and Hysteresis parameters per PCN-14441. 11/11/14
For the latest updates, visit our website: www.power.com
Power Integrations reserves the right to make changes to its products at any time to improve reliability or manufacturability. Power
Integrations does not assume any liability arising from the use of any device or circuit described herein. POWER INTEGRATIONS
MAKES NO WARRANTY HEREIN AND SPECIFICALLY DISCLAIMS ALL WARRANTIES INCLUDING, WITHOUT LIMITATION, THE
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
PARTY RIGHTS.
Patent Information
The products and applications illustrated herein (including transformer construction and circuits external to the products) may be
covered by one or more U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned to Power
Integrations. A complete list of Power Integrations patents may be found at www.power.com. Power Integrations grants its customers
a license under certain patent rights as set forth at http://www.power.com/ip.htm.
Life Support Policy
POWER INTEGRATIONS PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF POWER INTEGRATIONS. As used herein:
1. A Life support device or system is one which, (i) is intended for surgical implant into the body, or (ii) supports or sustains life, and (iii)
whose failure to perform, when properly used in accordance with instructions for use, can be reasonably expected to result in
significant injury or death to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to
cause the failure of the life support device or system, or to affect its safety or effectiveness.
The PI logo, TOPSwitch, TinySwitch, LinkSwitch, LYTSwitch, InnoSwitch, DPA-Switch, PeakSwitch, CAPZero, SENZero, LinkZero,
HiperPFS, HiperTFS, HiperLCS, Qspeed, EcoSmart, Clampless, E-Shield, Filterfuse, FluxLink, StakFET, PI Expert and PI FACTS are
trademarks of Power Integrations, Inc. Other trademarks are property of their respective companies. ©2014, Power Integrations, Inc.
World Headquarters
5245 Hellyer Avenue
San Jose, CA 95138, USA.
Main: +1-408-414-9200
Customer Service:
Phone: +1-408-414-9665
Fax: +1-408-414-9765
e-mail: usasales@power.com
China (Shanghai)
Rm 2410, Charity Plaza, No. 88
North Caoxi Road
Shanghai, PRC 200030
Phone: +86-21-6354-6323
Fax: +86-21-6354-6325
e-mail: chinasales@power.com
China (Shenzhen)
17/F, Hivac Building, No. 2, Keji
Nan 8th Road, Nanshan District,
Shenzhen, China, 518057
Phone: +86-755-8672-8689
Fax: +86-755-8672-8690
e-mail: chinasales@power.com
Germany
Lindwurmstrasse 114
80337 Munich
Germany
Phone: +49-895-527-39110
Fax: +49-895-527-39200
e-mail: eurosales@power.com
India
#1, 14th Main Road
Vasanthanagar
Bangalore-560052 India
Phone: +91-80-4113-8020
Fax: +91-80-4113-8023
e-mail: indiasales@power.com
Italy
Via Milanese 20, 3rd. Fl.
20099 Sesto San Giovanni (MI)
Italy
Phone: +39-024-550-8701
Fax: +39-028-928-6009
e-mail: eurosales@power.com
Japan
Kosei Dai-3 Bldg.
2-12-11, Shin-Yokohama,
Kohoku-ku
Yokohama-shi Kanagwan
222-0033 Japan
Phone: +81-45-471-1021
Fax: +81-45-471-3717
e-mail: japansales@power.com
Korea
RM 602, 6FL
Korea City Air Terminal B/D, 159-6
Samsung-Dong, Kangnam-Gu,
Seoul, 135-728, Korea
Phone: +82-2-2016-6610
Fax: +82-2-2016-6630
e-mail: koreasales@power.com
Singapore
51 Newton Road
#19-01/05 Goldhill Plaza
Singapore, 308900
Phone: +65-6358-2160
Fax: +65-6358-2015
e-mail: singaporesales@power.com
Taiwan
5F, No. 318, Nei Hu Rd., Sec. 1
Nei Hu Dist.
Taipei 11493, Taiwan R.O.C.
Phone: +886-2-2659-4570
Fax: +886-2-2659-4550
e-mail: taiwansales@power.com
UK
First Floor, Unit 15, Meadway
Court, Rutherford Close,
Stevenage, Herts. SG1 2EF
United Kingdom
Phone: +44 (0) 1252-730-141
Fax: +44 (0) 1252-727-689
e-mail: eurosales@power.com
Power Integrations Worldwide Sales Support Locations
LYT4221-4228/4321-4328
LYTSwitch-4 High Power LED Driver IC Family
www.power.com November 2014
Single-Stage Accurate Primary-Side Constant Current (CC) Controller with
PFC for High-Line Applications with TRIAC Dimming and Non-Dimming Options
This Product is Covered by Patents and/or Pending Patent Applications.
Product Highlights
Better than ±5% CC regulation
TRIAC dimmable to less than 5% output
Fast start-up
<250 ms at full brightness
<1s at 10% brightness
High power factor >0.9
Easily meets EN61000-3-2
Less than 10% THD in optimized designs
Up to 92% efficient
132 kHz switching frequency for small magnetics
High Performance, Combined Driver, Controller, Switch
The LYTSwitch-4 family enables off-line LED drivers with high
power factor which easily meet international requirements for
THD and harmonics. Output current is tightly regulated with
better than ±5% CC tolerance1. Efficiency of up to 92% is easily
achieved in typical applications.
Supports a Wide Selection of TRIAC Dimmers
The LYTSwitch-4 family provides excellent turn-on characteristics
for leading-edge and trailing-edge TRIAC dimming applications.
This results in drivers with a wide dimming range and fast
start-up, even when turning on from a low conduction angle –
large dimming ratio and low “pop-on” current.
Low Solution Cost and Long Lifetime
LYTSwitch-4 ICs are highly integrated and employ a primary-side
control technique that eliminates the optoisolator and reduces
component count. This allows the use of low-cost single-sided
printed circuit boards. Combining PFC and CC functions into a
single-stage also helps reduce cost and increase efficiency.
The 132 kHz switching frequency permits the use of small,
low-cost magnetics.
LED drivers using the LYTSwitch-4 family do not use primary-
side aluminum electrolytic bulk capacitors. This means greatly
extended driver lifetime, especially in bulb and other high
temperature applications.
Figure 1. Typical Schematic.
PI-6800-050913
LYTSwitch-4
AC
IN
D
S
BP
V
FBR
CONTROL
Part Number Input Voltage Range TRIAC Dimmable
LYT4221-LYT4228 160-308 VAC No
LY T4321-LY T4328 160-308 VAC Yes
Output Power Table1,2
Product6Minimum Output Power3Maximum Output Power 4
LYT4x21E56 W 12 W
LYT4x22E 6 W 15 W
LYT4x23E 8 W 18 W
LYT4x24E 9 W 22 W
LYT4x25E 11 W 25 W
LYT4x26E 14 W 35 W
LYT4x27E 19 W 50 W
LYT4x28E 33 W 78 W
Table 1. Output Power Table.
Notes:
1. Performance for typical design. See Application Note.
2. Continuous power in an open frame design with adequate heat sinking; device
local ambient of 70 °C. Power level calculated assuming a typical LED string
voltage and efficiency >80%.
3. Minimum output power requires CBP = 47 µF.
4. Maximum output power requires CBP = 4.7 µF.
5. LYT4321 CBP = 47 µF, LYT4221 CBP = 4.7 µF.
6. Package: eSIP-7C (see Figure 2).
Figure 2. Package Options.
eSIP-7C (E Package)
Optimized for Different Applications and Power Levels
Rev. C 11/14
2
LYT4221-4228/4321-4328
www.power.com
Figure 3d. Typical Buck-Boost Schematic.
Figure 3c. Typical Tapped Buck Schematic.
Figure 3b. Typical Buck Schematic.
Figure 3a. Typical Isolated Flyback Schematic.
Table 2. Performance of Different Topologies in a Typical Non-Dimmable 10 W High-Line Design.
PI-6800-050913
LYTSwitch-4
AC
IN
D
S
BP
V
FBR
CONTROL
Topology Isolation Efficiency Cost THD Output Voltage
Isolated Flyback Yes 88% High Best Any
Buck No 92% Low Good Limited
Tapped Buck No 89% Middle Best Any
Buck-Boost No 90% Low Best High-Voltage
Typical Circuit Schematic Key Features
Flyback
Benefits
Provides isolated output
Supports widest range of output voltages
Very good THD performance
Limitations
Flyback transformer
Overall efficiency reduced by parasitic capacitance
and inductance in the transformer
Larger PCB area to meet isolation requirements
Requires additional components (primary clamp and bias)
Higher RMS switch and winding currents increases losses
and lowers efficiency
Buck
Benefits
Highest efficiency
Lowest component count – small size
Simple low-cost power inductor
Low drain source voltage stress
Best EMI/lowest component count for filter
Limitations
Single input line voltage range
Output voltage <0.6 × VIN(AC) × 1.41
Output voltage for low THD designs
Non-isolated
Tapped Buck
Benefits
Ideal for low output voltage designs (<20 V)
High efficiency
Low component count
Simple low-cost tapped inductor
Limitations
Designs best suited for single input line voltage
Requires additional components (primary clamp)
Non-isolated
Buck-Boost
Benefits
Ideal for non-isolated high output voltage designs
High efficiency
Low component count
Simple common low-cost power inductor can be used
Lowest THD
Limitations
Maximum VOUT is limited by MOSFET breakdown voltage
Single input line voltage range
Non-isolated
PI-6841-111813
D
S
BP
V
FBR
CONTROL
AC
IN
LYTSwitch-4
PI-6842-111813
D
S
CONTROL
AC
IN V
FBR
LYTSwitch-4
BP
D
S
BP
V
FBR
CONTROL
AC
IN
LYTSwitch-4
PI-6859-111813
Rev. C 11/14
3
LYT4221-4228/4321-4328
www.power.com
Figure 5. Pin Configuration.
Pin Functional Description
DRAIN (D) Pin:
This pin is the power FET drain connection. It also provides
internal operating current for both start-up and steady-state
operation.
SOURCE (S) Pin:
This pin is the power FET source connection. It is also the
ground reference for the BYPASS, FEEDBACK, REFERENCE
and VOLTAGE MONITOR pins.
BYPASS (BP) Pin:
This is the connection point for an external bypass capacitor for
the internally generated 5.9 V supply. This pin also provides
output power selection through choice of the BYPASS pin
capacitor value.
FEEDBACK (FB) Pin:
The FEEDBACK pin is used for output voltage feedback. The
current into the FEEDBACK pin is directly proportional to the
output voltage. The FEEDBACK pin also includes circuitry to
protect against open load and overload output conditions.
REFERENCE (R) Pin:
This pin is connected to an external precision resistor and is
configured to use only 24.9 kW for non-dimming and dimming.
VOLTAGE MONITOR (V) Pin:
This pin interfaces with an external input line peak detector,
consisting of a rectifier, filter capacitor and resistors. The
applied current is used to control stop logic for overvoltage (OV),
provide feed-forward to control the output current and the
remote ON/OFF function.
PI-6843-071112
ILIM
DRAIN (D)
SOURCE (S)
BYPASS (BP)
VOLTAGE
MONITOR (V)
FEEDBACK (FB)
REFERENCE (R)
ILIM
VSENSE
MI
IS
5.9 V
5.0 V
BYPASS PIN
UNDERVOLTAGE
FAULT
PRESENT
Gate
Driver
SenseFet
OCP
CURRENT LIMIT
COMPARATOR
1 V
6.4 V
FBOFF
FBOFF
IFB
IV
DCMAX
DCMAX
Comparator
5.9 V
REGULATOR
SOFT-START
TIMER
JITTER
CLOCK
OSCILLATOR
AUTO-RESTART
COUNTER
BYPASS
CAPACITOR
SELECT
FEEDBACK
SENSE
PFC/CC
CONTROL
LINE
SENSE
HYSTERETIC
THERMAL
SHUTDOWN
+
-
+
-
+
-
3-VT
VBG
OV
REFERENCE
BLOCK
LEB
MI
VBG
STOP
LOGIC
PI-7076-062513
Exposed Pad
(Backside) Internally
Connected to
SOURCE Pin (see
eSIP-7C Package
Drawing)
E Package (eSIP-7C)
(Top View)
1 R
2 V
3 FB
4 BP
5 S
7 D
Figure 4. Functional Block Diagram.
Rev. C 11/14
4
LYT4221-4228/4321-4328
www.power.com
Functional Description
A LYTSwitch-4 device monolithically combines a controller and
high-voltage power FET into one package. The controller
provides both high power factor and constant current output in
a single-stage. The LYTSwitch-4 controller consists of an
oscillator, feedback (sense and logic) circuit, 5.9 V regulator,
hysteretic over-temperature protection, frequency jittering,
cycle-by-cycle current limit, auto-restart, inductance correction,
power factor and constant current control.
FEEDBACK Pin Current Control Characteristics
The figure shown below illustrates the operating boundaries of
the FEEDBACK pin current. Above IFB(SKIP) switching is disabled
and below IFB(AR) the device enters into auto-restart.
Figure 6. FEEDBACK Pin Current Characteristic.
The FEEDBACK pin current is also used to clamp the maximum
duty cycle to limit the available output power for overload and
open-loop conditions. This duty cycle reduction characteristic
also promotes a monotonic output current start-up characteristic
and helps preventing over-shoot.
REFERENCE Pin
The REFERENCE pin is tied to ground (SOURCE) via an external
resistor. The value selected sets the internal references and it
should be 24.9 kW ±1%. One percent resistors are recommended
as the resistor tolerance directly affects the output tolerance.
Other resistor values should not be used.
BYPASS Pin Capacitor Power Gain Selection
LYTSwitch-4 devices have the capability to tailor the internal
gain to either full or a reduced output power setting. This allows
selection of a larger device to minimize dissipation for both
thermal and efficiency reasons. The power gain is selected with
the value of the BYPASS pin capacitor. The full power setting is
selected with a 4.7 µF capacitor and the reduced power setting
(for higher efciency) is selected with a 47 µF capacitor. The
BYPASS pin capacitor sets both the internal power gain as well
as the over-current protection (OCP) threshold. Unlike the
larger devices, the LYT4x21 power gain is not programmable.
Use a 47 µF capacitor for the LYT4x21.
Switching Frequency
The switching frequency is 132 kHz during normal operation.
To further reduce the EMI level, the switching frequency is
jittered (frequency modulated) by approximately 5.4 kHz.
During start-up the frequency is 66 kHz to reduce start-up time
when the AC input is phase angle dimmed. Jitter is disabled in
deep dimming.
Soft-Start
The controller includes a soft-start timing feature which inhibits
the auto-restart protection feature for the soft-start period (tSOFT)
to distinguish start-up into a fault (short-circuit) from a large
output capacitor. At start-up the LYTSwitch-4 clamps the
maximum duty cycle to reduce the output power. The total
soft-start period is tSOFT.
Remote ON/OFF and EcoSmart
The VOLTAGE MONITOR pin has a 1 V threshold comparator
connected at its input. This voltage threshold is used for
remote ON/OFF control. When a signal is received at the
VOLTAGE MONITOR pin to disable the output (VOLTAGE
MONITOR pin tied to ground through an optocoupler photo-
transistor) the LYTSwitch-4 will complete its current switching
cycle before the internal power FET is forced off.
The remote ON/OFF feature can also be used as an eco-mode
or power switch to turn off the LYTSwitch-4 and keep it in a
very low power consumption state for indefinite long periods.
When the LYTSwitch-4 is remotely turned on after entering this
mode, it will initiate a normal start-up sequence with soft-start
the next time the BYPASS pin reaches 5.9 V. In the worst case,
the delay from remote on to start-up can be equal to the full
discharge/charge cycle time of the BYPASS pin. This reduced
consumption remote off mode can eliminate expensive and
unreliable in-line mechanical switches.
IFB(AR)
IFB(DCMAXR)
DC10 DCMAX
IFB(SKIP)
IFB
PI-6978-040213
Skip-Cycle
CC Control
Region
Soft-Start
Region
Auto-Restart
Maximum Duty Cycle
Rev. C 11/14
5
LYT4221-4228/4321-4328
www.power.com
Figure 7. Remote ON/OFF VOLTAGE MONITOR Pin Control.
5.9 V Regulator/Shunt Voltage Clamp
The internal 5.9 V regulator charges the bypass capacitor
connected to the BYPASS pin to 5.9 V by drawing a current
from the voltage on the DRAIN pin whenever the power FET is
off. The BYPASS pin is the internal supply voltage node. When
the power FET is on, the device operates from the energy stored
in the bypass capacitor. Extremely low power consumption of the
internal circuitry allows LYTSwitch-4 to operate continuously from
current it takes from the DRAIN pin. A bypass capacitor value
of 47 or 4.7 µF is sufcient for both high frequency decoupling
and energy storage. In addition, there is a 6.4 V shunt regulator
clamping the BYPASS pin at 6.4 V when current is provided to
the BYPASS pin through an external resistor. This facilitates
powering of LYTSwitch-4 externally through a bias winding to
increase operating efficiency. It is recommended that the
BYPASS pin is supplied current from the bias winding for
normal operation.
Auto-Restart
In the event of an open-loop fault (open FEEDBACK pin resistor
or broken path to feedback winding), output short-circuits or an
overload condition the controller enters into the auto-restart
mode. The controller annunciates both short-circuit and
open-loop conditions once the FEEDBACK pin current falls
below the IFB(AR) threshold after the soft-start period. To minimize
the power dissipation under this fault condition the shutdown/
auto-restart circuit turns the power supply on (same as the
soft-start period) and off at an auto-restart duty cycle of
typically DCAR for as long as the fault condition persists. If the
fault is removed during the auto-restart off-time, the power
supply will remain in auto-restart until the full off-time count is
completed. Special consideration must be made to appropriately
size the output capacitor to ensure that after the soft-start
period (tSOFT) the FEEDBACK pin current is above the IFB(AR)
threshold to ensure successful power-supply start-up. After the
soft-start time period, auto-restart is activated only when the
FEEDBACK pin current falls below IFB(AR).
Over-Current Protection
The current limit circuit senses the current in the power FET.
When this current exceeds the internal threshold (ILIMIT), the power
FET is turned off for the remainder of that cycle. A leading edge
blanking circuit inhibits the current limit comparator for a short
time (tLEB) after the power FET is turned on. This leading edge
blanking time has been set so that current spikes caused by
capacitance and rectifier reverse recovery will not cause
premature termination of the power FET conduction.
Line Overvoltage Protection
This device includes overvoltage detection to limit the maximum
operating voltage detected through the VOLTAGE MONITOR pin.
An external peak detector consisting of a diode and capacitor is
required to provide input line peak voltage to the VOLTAGE
MONITOR pin through a resistor.
The resistor sets line overvoltage (OV) shutdown threshold which,
once exceeded, forces the LYTSwitch-4 to stop switching. Once
the line voltage returns to normal, the device resumes normal
operation. A small amount of hysteresis is provided on the OV
threshold to prevent noise-generated toggling. When the power
FET is off, the rectified DC high voltage surge capability is
increased to the voltage rating of the power FET (725 V), due to the
absence of the reflected voltage and leakage spikes on the drain.
Hysteretic Thermal Shutdown
The thermal shutdown circuitry senses the controller die
temperature. The threshold is set at 142 °C typical with a 75 °C
hysteresis. When the die temperature rises above this threshold
(142 °C) the power FET is disabled and remains disabled until
the die temperature falls by 75 °C, at which point the power FET
is re-enabled.
Safe Operating Area (SOA) Protection
The device also features a safe operating area (SOA) protection
mode which disables FET switching for 40 cycles in the event
the peak switch current reaches the ILIMIT threshold and the switch
on-time is less than tON(SOA). This protection mode protects the
device under short-circuited LED conditions and at start-up during
the soft-start period when auto-restart protection is inhibited.
The SOA protection mode remains active in normal operation.
PI-5435-052510
D
S
BP
V
R FB
CONTROL
Rev. C 11/14
6
LYT4221-4228/4321-4328
www.power.com
Application Example
20 W TRIAC Dimmable High Power Factor LED Driver
Design Example (DER-396)
The circuit schematic in Figure 8 shows a TRIAC dimmable high
power factor LED driver based on LYT4324E from the LYTSwitch-4
high-line family of devices. The design is configurable for non-
dimmable only applications by simply changing the device to a
non-dimmable LYTSwitch-4 and removing the damper and
bleeder circuit. It was optimized to drive an LED string at a
voltage of 36 V with a constant current of 0.550 A ideal for high
Lumens PAR lamp retro-fit applications. The design operates
over an input voltage range of 185 VAC to 265 VAC.
The key goals of this design were compatibility with standard
leading edge TRIAC AC dimmers, very wide dimming range,
high efficiency (>85%) and high power factor (>0.9). The design
is fully protected from faults such as no-load (open-load), over-
voltage and output short-circuit or overload conditions and
over-temperature.
Circuit Description
The LYTSwitch-4 high-line device (U1-LYT4324E) integrates the
power FET, controller and start-up functions into a single package
reducing the component count versus typical implementations.
Configured as part of an isolated continuous conduction mode
flyback converter, U1 provides high power factor via its internal
control algorithm together with the small input capacitance of
the design. Continuous conduction mode operation results in
reduced primary peak and RMS current. This both reduces
EMI noise, allowing simpler, smaller EMI filtering components
and improves efciency. Output current regulation is maintained
without the need for secondary-side sensing which eliminates
current sense resistors and improves efficiency.
Input Stage
Fuse F1 provides protection from component failures while RV1
provides a clamp during differential line surges, keeping the
peak drain voltage of U1 below the device absolute maximum
rating of the internal power FET. Bridge rectifier BR1 rectifies
the AC line voltage. EMI filtering is provided by L1, L2, C4, C5,
R3 and R12 together with the safety rated Y class capacitor
(CY1) that bridges the safety isolation barrier between primary
and secondary. Resistor R3 and R12 damp any resonances
formed between L1, L2, C4 and the AC line impedance. A small
bulk capacitor (C5) is required to provide a low impedance path
for the primary switching current. The maximum value of C4
and C5 is limited in order to maintain a power factor of greater
than 0.9.
LYTSwitch-4 High-Line Primary
To provide peak line voltage information to U1 the incoming
rectified AC peak charges C6 via D2. This is then fed into the
VOLTAGE MONITOR pin of U1 as a current via R14 and R15.
This sensed current is also used by the device to set the line
input overvoltage protection threshold. Resistor R13 provides a
discharge path for C6 with a time constant much longer than that
of the rectified AC to minimize generation of line frequency ripple.
The VOLTAGE MONITOR pin current and the FEEDBACK pin
current are used internally to control the average output LED
current. For TRIAC phase-dimming or non-dimming applications
the same value of resistance 24.9 kW is used on the REFERENCE
pin resistor (R18) and 4 MW (R14 + R15) on the VOLTAGE MONITOR
pin to provide a linear relationship between input voltage and
the output current and maximizing the dimming range.
Figure 8. DER-396 Schematic of an Isolated, TRIAC Dimmable, High Power Factor, 185 – 265 VAC, 20 W / 36 V LED Driver.
R5
1 M
R6
2.4 M
R4
1 M
R8
162 k
1%
R7
162 k
1%
2 3
1 4
PI-7088-072913
D
S
BP
V
R FB
CONTROL
FL1
3 4
1 2
T1
RM7/1
1
7 FL2
6
8
R15
2 M
1%
R14
2 M
1%
R13
510 k
1/8 W
R12
47 k
R3
12 k
1/8 W
L1
RM5
R18
24.9 k
1%
1/16 W
R20
133 k
1%
1/8 W
R26
7.5 k
36 V,
550 mA
TP3
190 - 265
VAC
RTN
TP4
L
TP1
N
TP2
R21
20 k
1/8 W
C11
100 nF
50 V
R25
30
R22
39
1/8 W
R19
6.2 k
R23
10
1/10 W
D2
DFLU1400-7
C7
2.2 nF
630 V
D3
US1J
D5
BAV16WS-7-F
VR2
MMSZ5256BS-7-F
33 V
Q4
MMBT3904LT1G
Q2
MMBT3906
D7
BAV21WS-7-F
Q3
IRFU320PBF
D6
BAV21
D8
BYW29-200
D4
US1D
D1
BAV21
R24
1 k
1/10 W
BR1
B10S-G
1000 V
RV1
250 VAC
F1
5 A
C14
330 µF
63 V
C13
100 pF
200 V
CY1
470 pF
250 VAC
C15
330 µF
63 V
C8
100 µF
10 V
C12
100 nF
50 V
C10
10 nF
50 V
C9
56 µF
50 V
LYTSwitch-4
U1
LYT4324E
C6
2.2 µF
400 V
C5
220 nF
400 V
C4
120 nF
400 V
L2
5 mH
R10
15
R11
240
2 W
R9
30.1 k
1%
C2
47 pF
1 kV
VR1
1N5245B-T
15 V
C3
22 nF
50 V
Q1
MMBT3906
R28
510
1%
R27
510
1%
R2
510
1%
R1
510
1%
C1
220 nF
400 V
VR4
SMAJ200A-13-F
200 V
Rev. C 11/14
7
LYT4221-4228/4321-4328
www.power.com
Diode D3, VR4 and C7 clamp the drain voltage to a safe level
due to the effects of leakage inductance. Diode D4 is
necessary to prevent reverse current from flowing through U1
for the period of the rectified AC input voltage that the voltage
across C5 falls to below the reflected output voltage (VOR).
Diode D6, C9, C11, R21 and R22 create the primary bias supply
from an auxiliary winding on the transformer. Capacitor C8
provides local decoupling for the BYPASS pin of U1 which is the
supply pin for the internal controller. During start-up C8 is
charged to ~6 V from an internal high-voltage current source
tied to the device DRAIN pin. This allows the part to start
switching at which point the operating supply current is provided
from the bias supply via R19 and D5. Capacitor C8 also selects
the output power mode (47 µF for reduced power was selected
to reduce dissipation in U1 and increase efciency).
Feedback
The bias winding voltage is proportional to the output voltage
(set by the turn ratio between the bias and secondary windings).
This allows the output voltage to be monitored without secondary-
side feedback components. Resistor R20 converts the bias
voltage into a current which is fed into the FEEDBACK pin of U1.
The internal engine within LYTSwitch-4 (U1) combines the
FEEDBACK pin current, the VOLTAGE MONITOR pin current
and drain current information to provide a constant output
current over up to 1.5 : 1 output voltage variation (LED string
voltage variation of ±25%) at a fixed line input voltage.
To limit the output voltage at no-load an output overvoltage
protection circuit is set by D7, C12, R24, VR2, R23, C10 and Q4.
Should the output load be disconnected the bias voltage will
increase until VR2 conducts, biasing Q4 to turn on via R23 and
pulling down current going into the FEEDBACK pin. When the
feedback current drops below 10 µA the part enters auto-
restart and the switching of the MOSFET is disabled for 600 ms,
allowing time for the output and bias voltages to fall.
Output Rectification
The transformer secondary winding is rectified by D8 and
filtered by C14 and C15. An ultrafast TO-220 diode was
selected for efficiency and the combined value of C11 and C12
were selected to give peak-to-peak LED ripple current equal to
30% of the mean value. For designs where lower ripple is
desirable the output capacitance value can be increased.
A small pre-load is provided by R26 which discharges residual
charge in output capacitors when turned off.
TRIAC Phase Dimming Control Compatibility
The requirement to provide output dimming with low cost,
TRIAC-based, leading edge phase dimmers introduces a
number of trade-offs in the design.
Due to the much lower power consumed by LED based lighting
the current drawn by the overall lamp is below the holding
current and/or latching of the TRIAC within the dimmer. This
can cause undesirable behaviors such as limited dimming
range and/or flickering as the TRIAC fires inconsistently. The
relatively large impedance the LED lamp presents to the line
allows significant ringing to occur due to the inrush current
charging the input capacitance when the TRIAC turns on. This
too can cause similar undesirable behavior as the ringing may
cause the TRIAC current to fall to zero and turn off.
To overcome these issues two simple circuits, the MOSFET
active damper and RC passive bleeder were employed.
Employing these circuits however comes without penalty, since
their purpose is to satisfy the holding and latching current of a
TRIAC by providing some low impedance path for the TRIAC
current to flow continuously during the turn-on phase will
introduce additional dissipation and therefore reduced system
efficiency of the supply. For non-dimming applications these
circuits can simply be omitted (see Figure 9).
Power Integrations proprietary active damper circuit is used in
this design for achieving high efficiency, good dimmer
compatibility and line surge protection.
MOSFET Q3 is always on during non-dimming (no TRIAC
connected) operation. It bypasses the loss across the damper
resistor (R11) via the low RDS(ON) of the MOSFET Q3 thereby
maintaining high system efficiency. The gate of Q3 is biased
through the divider of R4, R5, and R6 and filtered by C13.
While Q3 is always on during non-dimming operation, MOSFET
Q3 operates differently during dimming. When the TRIAC turns
on at the beginning of every AC half-line cycle MOSFET Q3 is
off initially allowing the resistor (R11) to damp the current ringing
due to inrush of current induced by the input bulk capacitance
and EMI filter impedance. After approximately 1 ms Q3 turns
on and bypasses R11. The effect is increased compatibility with
different types of dimmers.
During differential line surge occurrence where a high dv/dt is
detected through the RC high-pass filter R7, R8 and C2.
Transistor Q2 will turn off Q3 and a voltage proportional to the
input current that will develop across the damper resistor will be
subtracted from the input thus limiting the voltage stress on the
DRAIN pin of U1.
Resistor R9 bleeds the charge from C2 and ensures Q2 is off
during normal operation.
The passive bleeder circuit is comprised of R1, R2, R27, R28
and C1. This network helps keep the input current above the
TRIAC holding current while the input current corresponding to
the effective driver resistance increases during each AC half-cycle.
Rev. C 11/14
8
LYT4221-4228/4321-4328
www.power.com
Modified DER-396 20 W High Power Factor LED Driver
for Non-Dimmable and Enhanced Line Regulation
The circuit schematic in Figure 9 shows a high power factor
LED driver based on a LYT4224E from the LYTSwitch-4 non-
dimming high-line family of devices. It was optimized to drive
an LED string at a voltage of 36 V with a constant current of
0.55 A, ideal for high lumens PAR lamp retro-fit applications.
The design operates over the high-line input voltage range of
185 VAC to 265 VAC and is non-dimming application. A non-
dimming application has tighter output current variation with
changes in the line voltage than a dimming application. It’s key
to note that, although not specified for dimming, no circuit
damage will result if the end user does operate the design with
a phase controlled dimmer.
Modification for Non-Dimmable Configuration
The DER-396 is configurable for non-dimmable application by
simply removing the components of the MOSFET active damper
(R4, R5, R6, R7, R8, R9, R10, R11, D1, Q1, Q2, C3, and VR1)
and passive R-C bleeder (R1, R2, R27, R28 and C1) and replacing
the IC U1 to LYT4224E, non-dimmable device LYTSwitch-4 non-
dimming high-line family. For non-dimmable application audible
noise is not critical so L1 and L2 can be replaced with a regular
off-the-shelf dog bone inductor for cost reduction (See Figure 9).
Key Application Considerations
Power Table
The data sheet power table (Table 1) represents the minimum
and maximum practical continuous output power based on the
following assumed conditions:
Efficiency of 85%
Device local ambient of 70 °C
Sufficient heat sinking to keep the device temperature
below 100 °C
For minimum output power column
Reflected output voltage (VOR) of 135 V
FEEDBACK pin current of 135 µA
BYPASS pin capacitor value of 47 µF
For maximum output power column
Reflected output voltage (VOR) of 90 V
FEEDBACK pin current of 165 µA
BYPASS pin capacitor value of 4.7 µF
(LYT4x21 = 4.7 µF)
Note that input line voltages above 185 VAC do not change the
power delivery capability of LYTSwitch-4 high-line devices.
Device Selection
Select the device size by comparing the required output power
to the values in Table 1. For thermally challenging designs, e.g.,
incandescent lamp replacement, where either the ambient
temperature local to the LYTSwitch-4 high-line device is high
and/or there is minimal space for heat sinking use the minimum
output power column. This is selected by using a 47 µF BYPASS
pin capacitor and results in a lower device current limit and
therefore lower conduction losses. For open frame design or
designs where space is available for heat sinking then refer to the
maximum output power column. This is selected by using a
4.7 µF BYPASS pin capacitor for all but the LYT4x21 which has only
one power setting. In all cases in order to obtain the best output
current tolerance maintain the device temperature below 100 °C.
Figure 9. Modified Schematic of DER-396 for Non-Dimmable, Isolated, High Power Factor, 185-265 VAC, 20 W / 36 V LED Driver.
PI-7089-102313
D
S
BP
V
R FB
CONTROL
FL1
T1
RM7/1
1
7 FL2
6
8
R15
2 M
1%
R14
2 M
1%
VR4
SMAJ200A-13-F
200 V
R13
510 k
1/8 W
R18
24.9 k
1%
1/16 W
R20
133 k
1%
1/8 W
R26
7.5 k
36 V,
550 mA
TP3
RTN
TP4
R21
20 k
1/8 W
C11
100 nF
50 V
R25
30
R22
39
1/8 W
R19
6.2 k
R23
10
1/10 W
D2
DFLU1400-7
C7
2.2 nF
630 V
D3
US1J
D5
BAV16WS-7-F
VR2
MMSZ5256BS-7-F
33 V
Q4
MMBT3904LT1G
D7
BAV21WS-7-F
D6
BAV21
D8
BYW29-200
D4
US1D
R24
1 k
1/10 W
C14
330 µF
63 V
C13
100 pF
200 V
CY1
470 pF
250 VAC
C15
330 µF
63 V
C8
47 µF
16 V
C12
100 nF
50 V
C10
10 nF
50 V
C9
56 µF
50 V
LYTSwitch-4
U1
LYT4224E
C6
2.2 µF
400 V
C5
220 nF
400 V
R3
12 k
1/8 W
L1
1.5 mH
L3
1.5 mH
190 - 265
VAC
L
TP1
N
TP2
BR1
B10S-G
1000 V
RV1
250 VAC
F1
5 A
C4
120 nF
400 V
R29
12 k
1/8 W
R12
47 k
1/8 W
L2
1.5 mH
Rev. C 11/14
9
LYT4221-4228/4321-4328
www.power.com
Maximum Input Capacitance
To achieve high power factor, the capacitance used in both the
EMI filter and for decoupling the rectified AC (bulk capacitor)
must be limited in value. The maximum value is a function of
the output power of the design and reduces as the output
power reduces. For the majority of designs limit the total
capacitance to less than 220 nF with a bulk capacitor value of
100 nF. Film capacitors are recommended compared to
ceramic types as they minimize audible noise with operating
with leading edge phase dimmers. Start with a value of 10 nF
for the capacitance in the EMI filter and increase in value until
there is sufficient EMI margin.
REFERENCE Pin Resistance Value Selection
The LYTSwitch-4 high-line family contains phase dimming
devices, LYT4321-4328, and non-dimming devices, LYT4221-
4228. Both the non-dimmable devices and dimmable devices
use 24.9 kW ±1% REFERENCE pin resistor for best output
current tolerance (over AC input voltage changes).
VOLTAGE MONITOR Pin Resistance Network Selection
For widest AC phase angle dimming range with LYT4321-4328,
use a 4 MW resistor connected to the line voltage peak detector
circuit. Make sure that the resistor’s voltage rating is sufficient
for the peak line voltage. If necessary use multiple series
connected resistors.
Primary Clamp and Output Reflected Voltage VOR
A primary clamp is necessary to limit the peak drain to source
voltage. A Zener clamp requires the fewest components and
board space and gives the highest efficiency. RCD clamps are
also acceptable however the peak drain voltage should be care-
fully verified during start-up and output short-circuits as the
clamping voltage varies with significantly with the peak drain
current.
For the highest efficiency, the clamping voltage should be
selected to be at least 1.5 times the output reflected voltage,
VOR, as this keeps the leakage spike conduction time short.
When using a Zener clamp in a universal input or high-line only
application, a VOR of less than 135 V is recommended to allow
for the absolute tolerances and temperature variations of the
Zener. This will ensure efficient operation of the clamp circuit
and will also keep the maximum drain voltage below the rated
breakdown voltage of the FET. An RCD (or RCDZ) clamp
provides tighter clamp voltage tolerance than a Zener clamp.
The RCD clamp is more cost-effective than the Zener clamp but
requires more careful design to ensure that the maximum drain
voltage does not exceed the power FET breakdown voltage.
These VOR limits are based on the BVDSS rating of the internal
FET, a VOR of 90 V to 120 V is typical for most designs, giving
the best PFC and regulation performance.
Series Drain Diode
An ultrafast or Schottky diode in series with the drain is
necessary to prevent reverse current flowing through the device.
The voltage rating must exceed the output reflected voltage,
VOR. The current rating should exceed two times the average
primary current and have a peak rating equal to the maximum
drain current of the selected LYTSwitch-4 high-line device.
Line Voltage Peak Detector Circuit
LYTSwitch-4 high-line devices use the peak line voltage to
regulate the power delivery to the output. A capacitor value of
1 µF to 4.7 µF is recommended to minimize line ripple and give
the highest power factor (>0.9), smaller values are acceptable
but result in lower PF and higher line current distortion.
Operation with Phase Controlled Dimmers
Dimmer switches control incandescent lamp brightness by not
conducting (blanking) for a portion of the AC voltage sine wave.
This reduces the RMS voltage applied to the lamp thus reducing
the brightness. This is called natural dimming and the LYTSwitch-4
high-line LYT4321-4328 devices when configured for dimming
utilize natural dimming by reducing the LED current as the RMS
line voltage decreases. By this nature, line regulation performance
is purposely decreased to increase the dimming range and
more closely mimic the operation of an incandescent lamp.
Leading Edge Phase Controlled Dimmers
The requirement to provide flicker-free output dimming with low-
cost, TRIAC-based, leading edge phase dimmers introduces a
number of trade-offs in the design.
Due to the much lower power consumed by LED based lighting
the current drawn by the overall lamp is below the holding
current of the TRIAC within the dimmer. This causes undesirable
behaviors such as limited dimming range and/or flickering. The
relatively large impedance the LED lamp presents to the line
allows significant ringing to occur due to the inrush current
charging the input capacitance when the TRIAC turns on. This
too can cause similar undesirable behavior as the ringing may
cause the TRIAC current to fall to zero and turn off.
To overcome these issues two circuits, the active damper and
passive bleeder, are incorporated. The drawback of these
circuits is increased dissipation and therefore reduced efficiency
of the supply so for non-dimming applications these components
can simply be omitted.
Figure 10(a) shows the line voltage and current at the input of a
leading edge TRIAC dimmer with Figure 10(b) showing the
resultant rectified bus voltage. In this example, the TRIAC
conducts at 90 degrees.
Figure 11 shows undesired rectified bus voltage and current
with the TRIAC turning off prematurely and restarting.
If the TRIAC is turning off before the end of the half-cycle
erratically or alternate half AC cycles have different conduction
angles then flicker will be observed in the LED light due to
variations in the output current. This can be solved by including
a bleeder and damper circuit.
Dimmers will behave differently based on manufacturer and
power rating, for example a 300 W dimmer requires less
dampening and requires less power loss in the bleeder than a
600 W or 1000 W dimmer due to different drive circuits and
TRIAC holding current specifications. Line voltage also has a
significant impact as at high-line for a given output power the
Rev. C 11/14
10
LYT4221-4228/4321-4328
www.power.com
input current and therefore TRIAC current is lower but the peak
inrush current when the input capacitance charges is higher
creating more ringing. Finally multiple lamps in parallel driven from
the same dimmer can introduce more ringing due to the increased
capacitance of parallel units. Therefore, when testing dimmer
operation verify on a number of models, different line voltages
and with both a single driver and multiple drivers in parallel.
Start by adding a bleeder circuit. Add a 0.44 µF capacitor and
510 W 1 W resistor (components in series) across the rectified
bus (C1 and R1, R2, R27, R28 in Figure 8). If the results in
satisfactory operation reduce the capacitor value to the smallest
that result in acceptable performance to reduce losses and
increase efficiency.
If the bleeder circuit does not maintain conduction in the TRIAC,
then add an active damper as shown in Figure 8. This circuit
limits the inrush current that flows to charge C4 and C5 when
the TRIAC turns on by placing the damper resistor (R11, R29) in
series for the first 1 ms of the TRIAC conduction. After approxi-
mately 1 ms, Q3 turns on and shorts the damper resistor. This
keeps the power dissipation on the damper resistor low and
allows a larger value to be used during current limiting. Increasing
the delay before Q3 turns on by increasing the value of capacitor
050 100 150 200 250 400350300
Conduction Angle (°)
Rectified Input Voltage (V)
Rectified Input Current (A)
350
300
250
200
150
100
50
0
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
PI-5985-060810
Voltage
Current
Figure 11. Example of Phase Angle Dimmer Showing Erratic Firing.
50 100 150 200 250 300 350
Conduction Angle (°)
Dimmer Output Voltage (V)
Dimmer Output Current (A)
350
250
150
50
-50
-150
-250
-350
0.35
0.25
0.15
0.05
-0.05
-0.15
-0.25
-0.35
PI-5986-060810
Voltage
Current
0
Figure 12. Ideal Dimmer Output Voltage and Current Waveforms for a Trailing
Edge Dimmer at 90° Conduction Angle.
50 100 150 200 250 300 350 400
Conduction Angle (°)
Line Voltage (at Dimmer Input) (V)
Line Current (Through Dimmer) (A)
350
250
150
50
-50
-150
-250
-350
0.35
0.25
0.15
0.05
-0.05
-0.15
-0.25
-0.35
PI-5983-060810
Voltage
Current
0.5
050 100 150 200 250 400350300
Conduction Angle (°)
Rectified Input Voltage (V)
Rectified Input Current (A)
350
300
250
200
150
100
50
0
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
PI-5984-060810
Voltage
Current
Figure 10b. Resultant Waveforms Following Rectification of TRIAC Dimmer Output.
Figure 10a. Ideal Input Voltage and Current Waveforms for a Leading Edge
TRIAC Dimmer at 90° Conduction Angle.
C3 will improve dimmer compatibility but cause more power to
be dissipated across the damper resistor. Monitor the AC line
current and voltage at the input of the power supply as you
make the adjustments. Increase the delay until the TRIAC
operates properly but keep the delay as short as possible for
efficiency.
As a general rule the greater the power dissipated in the bleeder
and damper circuits, the more types of dimmers will work with
the driver.
Trailing Edge Phase Controlled Dimmers
Figure 12 shows the line voltage and current at the input of the
power supply with a trailing edge dimmer. In this example, the
dimmer conducts at 90 degrees. Many of these dimmers use
back-to-back connected power FETs rather than a TRIAC to
control the load. This eliminates the holding current issue of
TRIACs and since the conduction begins at the zero crossing, high
current surges and line ringing are minimized. These types of
dimmers do not require damping circuits but do require a
bleeder. However the bleeder ensures that the AC voltage
across the dimmer falls to a low enough level for the dimmer to
correctly detect zero crossing. This is used internally by the
dimmer for timing.
Rev. C 11/14
11
LYT4221-4228/4321-4328
www.power.com
Figure 13. DER-396 20 W Layout Example, Top Silkscreen / Bottom Layer.
Audible Noise Considerations for use with
Leading Edge Dimmers
Noise created when dimming is typically created by the input
capacitors, EMI filter inductors and the transformer. The input
capacitors and inductors experience high di/dt and dv/dt every
AC half-cycle as the TRIAC fires and an inrush current flows to
charge the input capacitance. Noise can be minimized by
selecting film vs. ceramic capacitors, minimizing the capacitor
value and selecting inductors that are physically short and wide.
The transformer may also create noise which can be minimized
by avoiding cores with long narrow legs (high mechanical
resonant frequency). For example, RM cores produce less
audible noise than EE cores for the same flux density. Reducing
the core flux density will also reduce the noise. Reducing the
maximum flux density (BM) to 1500 Gauss usually eliminates
any audible noise but must be balanced with the increased core
size needed for a given output power.
Thermal and Lifetime Considerations
Lighting applications present thermal challenges to the driver.
In many cases the LED load dissipation determines the working
ambient temperature experienced by the drive so thermal
evaluation should be performed with the driver inside the final
enclosure. Temperature has a direct impact on driver and LED
lifetime. For every 10 °C rise in temperature, component life is
reduced by a factor of 2. Therefore it is important to properly
heat sink and to verify the operating temperatures of all devices.
Layout Considerations
Primary-Side Connections
Use a single point (Kelvin) connection at the negative terminal of
the input filter capacitor for the SOURCE pin and bias returns.
This improves surge capabilities by returning surge currents
from the bias winding directly to the input filter capacitor. The
BYPASS pin capacitor should be located as close to the BYPASS
pin and connected as close to the SOURCE pin as possible.
The SOURCE pin trace should not be shared with the main
power FET switching currents. All FEEDBACK pin components
that connect to the SOURCE pin should follow the same rules
as the BYPASS pin capacitor. It is critical that the main power
FET switching currents return to the bulk capacitor with the
shortest path as possible. Long high current paths create
excessive conducted and radiated noise.
Secondary-Side Connections
The output rectifier and output filter capacitor should be as
close as possible. The transformer’s output return pin should
have a short trace to the return side of the output filter capacitor.
PI-7096-102313
Output
Capacitors
VOLTAGE MONITOR Pin
Resistor
FEEDBACK Pin
Resistor
REFERENCE Pin
Resistor
Input EMI Filter
LYT4224E
Bullk
Capacitor
Clamp Transformer Output
Diode
Output
Capacitor
BYPASS Pin
Capacitor
Rev. C 11/14
12
LYT4221-4228/4321-4328
www.power.com
Quick Design Checklist
Maximum Drain Voltage
Verify that the peak VDS does not exceed the device absolute
maximum rating under all operating conditions including
start-up and fault conditions.
Maximum Drain Current
Measure the peak drain current under all operation conditions
including start-up and fault conditions. Look for signs of
transformer saturation (usually occurs at highest operating
ambient temperatures). Verify that the peak current is less than
the stated Absolute Maximum Rating in the data sheet.
Thermal Check
At maximum output power, both minimum and maximum line
voltage and ambient temperature; verify that temperature
specifications are not exceeded for the LYTSwitch-4 high-line,
transformer, output diodes, output capacitors and drain clamp
components.
Rev. C 11/14
13
LYT4221-4228/4321-4328
www.power.com
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
Control Functions
Switching Frequency fOSC TJ = 65 °C
Average 124 132 140
kHz
Peak-Peak Jitter 5.4
Frequency Jitter
Modulation Rate fM
TJ = 65 °C
See Note B 2.6 kHz
BYPASS Pin
Charge Current
ICH1
VBP = 0 V,
TJ = 65 °C
LYT4x21 -6.04 -3.45 -2.59
mA
LYT4x22 -10.89 -6.22 -4.67
LY T4x 23 -16.21 -9.26 -6.95
LYT4x24 -21.88 -12.5 -9.38
LYT4x25 -26.25 -15.0 -11.25
LYT4x26 -15.75 -9.00 -6.75
LYT4x27 -17.50 -10.0 -7.50
LYT4x28 -20.65 -11.8 -8.85
ICH2
VBP = 5 V,
TJ = 65 °C
LYT4x21 -1.23 -0.7 -0.49
LYT4x22 -4.38 -2.5 -1.75
LY T4x 23 -8.05 -4.6 -3.22
LYT4x24 -11.64 -6.65 -4.66
LYT4x25 -15.10 -8.63 -6.04
LYT4x26 -7.61 -4.35 -3.05
LYT4x27 -9.22 -5.27 -3.69
LYT4x28 -10.15 -5.8 -4.06
Absolute Maximum Ratings(1,4)
DRAIN Pin Peak Current(5): LY T4x 21 ................................. 1.37 A
LY T4x 22 .................................2.08 A
LY T4x 23 ................................. 2.72 A
LY T4x 24 ................................ 4.08 A
LY T4x 25 ................................ 5.44 A
LY T4x 26 ................................ 6.88 A
LY T4x 27 ................................. 7. 3 3 A
LY T4x 28 ...................................9.0 A
DRAIN Pin Voltage ……………………… ................. -0.3 to 725 V
BYPASS Pin Voltage ................................................. -0.3 to 9 V
BYPASS Pin Current ……………………… ...................... 100 mA
VOLTAGE MONITOR Pin Voltage .............................-0.3 to 9 V(6)
FEEDBACK Pin Voltage ….. ................................... -0.3 to 9 V
REFERENCE Pin Voltage .......................................... -0.3 to 9 V
Lead Temperature(3) ........................................................260 °C
Storage Temperature …………………. .................. -65 to 150 °C
Operating Junction Temperature(2) .........................-40 to 150 °C
Notes:
1. All voltages referenced to SOURCE, TA = 65 °C.
2. Normally limited by internal circuitry.
3. 1/16 in. from case for 5 seconds.
4. Absolute Maximum Ratings specified may be applied, one
at a time without causing permanent damage to the
product. Exposure to Absolute Maximum Ratings for
extended periods of time may affect product reliability.
5. Peak DRAIN current is allowed while the DRAIN voltage is
simultaneously less than 400 V. See also Figure 10.
6. During start-up (the period before the BYPASS pin begins
powering the IC) the VOLTAGE MONITOR pin voltage can
safely rise to 15 V without damage.
Thermal Resistance
Thermal Resistance: E Package
(qJA) ....................................................105 °C/W(1)
(qJC) .................................................... 2 °C/W(2)
Notes:
1. Free standing with no heat sink.
2. Measured at back surface tab.
Rev. C 11/14
14
LYT4221-4228/4321-4328
www.power.com
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
Control Functions (cont.)
Charging Current
Temperature Drift See Note A, B 0.7 %/°C
BYPASS Pin Voltage VBP 0 °C < TJ < 100 °C 5.75 5.95 6.15 V
BYPASS Pin
Voltage Hysteresis VBP(H) 0 °C < TJ < 100 °C 0.85 V
BYPASS Pin
Shunt Voltage VBP(SHUNT)
IBP = 4 mA
0 °C < TJ < 100 °C 6.1 6.4 6.7 V
Soft-Start Time tSOFT
TJ = 65 °C
VBP = 5.9 V 51 72 ms
Drain Supply Current
ICD2
0 °C < TJ < 100 °C
FET Not Switching 0.5 0.8 1.2
mA
ICD1
0 °C < TJ < 100 °C
FET Switching at fOSC
1 2.5 4
VOLTAGE MONITOR Pin
Line Overvoltage
Threshold IOV
TJ = 65 °C
RR = 24.9 kW
Threshold 105 112 119
µA
Hysteresis 5
VOLTAGE MONITOR
Pin Voltage VV
0 °C < TJ < 100 °C
IV < IOV
LYT4x21-4x28 2.75 3.00 3.25 V
VOLTAGE MONITOR Pin
Short-Circuit Current IV(SC)
VV = 5 V
TJ = 65 °C LYT4x27-4x28 150 175 200 µA
Remote ON/OFF
Threshold VV(REM) TJ = 65 °C 0.5 V
FEEDBACK Pin
FEEDBACK Pin Current
at Onset of Maximum
Duty Cycle
IFB(DCMAXR) 0 °C < TJ < 100 °C 90 µA
FEEDBACK Pin Current
Skip Cycle Threshold IFB(SKIP) TJ = 65 °C 210 µA
Maximum Duty Cycle DCMAX
IFB(DCMAXR) < IFB < IFB(SKIP)
0 °C < TJ < 100 °C 85 99.9 %
FEEDBACK Pin Voltage VFB
IFB = 150 µA
0 °C < TJ < 100 °C 2.1 2.3 2.56 V
FEEDBACK Pin
Short-Circuit Current IFB(SC)
VFB = 5 V
TJ = 65 °C 320 380 480 µA
Duty Cycle Reduction
DC10 IFB = IFB(AR), TJ = 65 °C, See Note B 13
%DC40 IFB = 40 µA, TJ = 65 °C 37
DC60 IFB = 60 µA, TJ = 65 °C 60
Auto-Restart
Auto-Restart ON-Time tAR
TJ = 65 °C
VBP = 5.9 V 51 72 ms
Rev. C 11/14
15
LYT4221-4228/4321-4328
www.power.com
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
Auto-Restart (cont.)
Auto-Restart
Duty Cycle DCAR
TJ = 65 °C
See Note B 12.5 %
SOA Minimum Switch
ON-Time tON(SOA)
TJ = 65 °C
See Note B 0.875 µs
FEEDBACK Pin Current
During Auto-Restart IFB(AR) 0 °C < TJ < 100 °C 6.5 10 µA
REFERENCE Pin
REFERENCE Pin
Voltage VRRR = 24.9 kW
0 °C < TJ < 100 °C
1.223 1.245 1.273 V
REFERENCE Pin
Current IR48.69 49.94 51.19 µA
Current Limit/Circuit Protection
Full Power
Current Limit
(CBP = 4.7 µF)
ILIMIT(F)
TJ = 65 °C
di/dt = 138 mA/µs LYT4x22 0.79 0.92
A
di/dt = 145 mA/µs LYT4x23 0.99 1.15
di/dt = 180 mA/µs LYT4x24 1.18 1.38
di/dt = 227 mA/µs LYT4x25 1.41 1.63
di/dt = 272 mA/µs LYT4x26 1.89 2.19
di/dt = 375 mA/µs LYT4x27 2.61 3.03
Reduced Power
Current Limit
(CBP = 47 µF)
ILIMIT(R)
TJ = 65 °C
di/dt = 110 mA/µs LYT4x21 0.59 0.69
A
di/dt = 158 mA/µs LYT4x22 0.65 0.76
di/dt = 155 mA/µs LYT4x23 0.8 0.93
di/dt = 188 mA/µs LYT4x24 0.95 1.11
di/dt = 240 mA/µs LYT4x25 1.14 1.33
di/dt = 300 mA/µs LYT4x26 1.38 1.61
di/dt = 415 mA/µs LYT4x27 1.88 2.18
di/dt = 770 mA/µs LYT4x28 3.92 4.56
Minimum
ON-Time Pulse tLEB + tIL(D) TJ = 65 °C 270 450 630 ns
Leading Edge
Blanking Time tLEB
TJ = 65 °C
See Note B 110 375 ns
Current Limit Delay tIL(D)
TJ = 65 °C
See Note B 150 ns
Thermal Shutdown
Temperature See Note B LYT4x21-4x28 147 155 164 °C
Thermal Shutdown
Hysteresis See Note B 56 °C
BYPASS Pin Power-Up
Reset Threshold
Voltage
VBP(RESET) 0 °C < TJ < 100 °C 2.25 3.30 4.25 V
Rev. C 11/14
16
LYT4221-4228/4321-4328
www.power.com
Parameter Symbol
Conditions
SOURCE = 0 V; TJ = -20 °C to 125 °C
(Unless Otherwise Specified)
Min Typ Max Units
Output
NOTES:
A. For specifications with negative values, a negative temperature coefficient corresponds to an increase in magnitude with increasing
temperature and a positive temperature coefficient corresponds to a decrease in magnitude with increasing temperature.
B. Guaranteed by characterization. Not tested in production.
Note: The parameter values and limits specified herein are based on a limited data set. There is a small likelihood that minor
changes may be required based on additional data as they become available.
ON-State Resistance RDS(ON)
LYT4x21
ID = 100 mA
TJ = 65 °C 11.5 13.2
W
TJ = 100 °C 13.5 15.5
LYT4x22
ID = 100 mA
TJ = 65 °C 6.9 8.0
TJ = 100 °C 8.4 9.7
LYT4x23
ID = 150 mA
TJ = 65 °C 5.3 6.0
TJ = 100 °C 6.3 7.3
LYT4x24
ID = 150 mA
TJ = 65 °C 3.4 3.9
TJ = 100 °C 3.9 4.5
LYT4x25
ID = 200 mA
TJ = 65 °C 2.5 2.9
TJ = 100 °C 3.0 3.4
LYT4x26
ID = 250 mA
TJ = 65 °C 1.9 2.2
TJ = 100 °C 2.3 2.7
LYT4x27
ID = 350 mA
TJ = 65 °C 1.8 2.0
TJ = 100 °C 2.1 2.5
LYT4x28
ID = 600 mA
TJ = 65 °C 1.3 1.5
TJ = 100 °C 1.6 1.9
OFF-State Drain
Leakage Current IDSS
VBP = 6.4 V
VDS = 560 V
TJ = 100 °C
50 µA
Breakdown Voltage BVDSS
VBP = 6.4 V
TJ = 65 °C 725 V
Minimum Drain
Supply Voltage TJ < 100 °C 36 V
Rise Time tRMeasured in a Typical Flyback
See Note B
100 ns
Fall Time tF50 ns
Rev. C 11/14
17
LYT4221-4228/4321-4328
www.power.com
Typical Performance Characteristics
Figure 14. Drain Capacitance vs. Drain Pin Voltage. Figure 15. Power vs. Drain Voltage.
Figure 16. Drain Current vs. Drain Voltage. Figure 17. Maximum Allowable Drain Current vs. Drain Voltage.
1 100 200 300 400 500 600
10
100
1000
10000
PI-6965-102313
DRAIN Pin Voltage (V)
DRAIN Capacitance (pF)
LYT4x21 0.18
LYT4x22 0.28
LYT4x23 0.38
LYT4x24 0.56
LYT4x25 0.75
LYT4x26 1.00
LYT4x27 1.16
LYT4x28 1.55
Scaling Factors:
300
100
200
0
0 200100 400 500 600300 700
DRAIN Voltage (V)
Power (mW)
PI-6966-102313
LYT4x21 0.18
LYT4x22 0.28
LYT4x23 0.38
LYT4x24 0.56
LYT4x25 0.75
LYT4x26 1.00
LYT4x27 1.16
LYT4x28 1.55
Scaling Factors:
0
02 4 6 8 10 12 14 16 18 20
DRAIN Voltage (V)
DRAIN Current (A)
PI-6967-102313
2
3
1
LYT42x8 TCASE = 25 °C
LYT42x8 TCASE = 100 °C
4
5
LYT4x21 0.18
LYT4x22 0.28
LYT4x23 0.38
LYT4x24 0.56
LYT4x25 0.75
LYT4x26 1.00
LYT4x27 1.16
LYT4x28 1.55
Scaling Factors:
0
0100 200 300 400 600500 700 800
DRAIN Voltage (V)
DRAIN Current
(Normalized to Absolute Maximum Rating)
PI-6010-060410
0.6
0.8
0.4
0.2
1
1.2
Rev. C 11/14
18
LYT4221-4228/4321-4328
www.power.com
PI-4917-061510
MOUNTING HOLE PATTERN
(not to scale)
PIN 7
PIN 1
0.100 (2.54) 0.100 (2.54)
0.059 (1.50)
0.059 (1.50)
0.050 (1.27)
0.050 (1.27)
0.100 (2.54)
0.155 (3.93)
0.020 (0.50)
Notes:
1. Dimensioning and tolerancing per ASME Y14.5M-1994.
2. Dimensions noted are determined at the outermost
extremes of the plastic body exclusive of mold flash,
tie bar burrs, gate burrs, and interlead flash, but including
any mismatch between the top and bottom of the plastic
body. Maximum mold protrusion is 0.007 [0.18] per side.
3. Dimensions noted are inclusive of plating thickness.
4. Does not include inter-lead flash or protrusions.
5. Controlling dimensions in inches (mm).
0.403 (10.24)
0.397 (10.08)
0.325 (8.25)
0.320 (8.13)
0.050 (1.27)
FRONT VIEW
2
2
B
A
0.070 (1.78) Ref.
Pin #1
I.D.
3
C
0.016 (0.41)
Ref.
0.290 (7.37)
Ref.
0.047 (1.19)
0.100 (2.54)
0.519 (13.18)
Ref.
0.198 (5.04) Ref.
0.264 (6.70)
Ref.
0.118 (3.00)
3
0.140 (3.56)
0.120 (3.05)
0.021 (0.53)
0.019 (0.48)
0.378 (9.60)
Ref. 0.019 (0.48) Ref.
0.060 (1.52)
Ref.
0.048 (1.22)
0.046 (1.17)
0.081 (2.06)
0.077 (1.96)
0.207 (5.26)
0.187 (4.75)
0.033 (0.84)
0.028 (0.71)
0.016 (0.41)
0.011 (0.28)
eSIP-7C (E Package)
10° Ref.
All Around
0.020 M 0.51 M C
0.010 M 0.25 M C A B
SIDE VIEW
END VIEW
BACK VIEW
4
0.023 (0.58)
0.027 (0.70)
DETAIL A
Detail A
Rev. C 11/14
19
LYT4221-4228/4321-4328
www.power.com
Part Ordering Information
• LYTSwitch Product Family
• 4 Series Number
• PFC/Dimming
2 PFC No Dimming
3 PFC Dimming
• Voltage Range
2 High-Line
• Device Size
• Package Identifier
E eSIP-7C
LYT 4 2 2 3 E
For the latest updates, visit our website: www.power.com
Power Integrations reserves the right to make changes to its products at any time to improve reliability or manufacturability. Power
Integrations does not assume any liability arising from the use of any device or circuit described herein. POWER INTEGRATIONS
MAKES NO WARRANTY HEREIN AND SPECIFICALLY DISCLAIMS ALL WARRANTIES INCLUDING, WITHOUT LIMITATION, THE
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
PARTY RIGHTS.
Patent Information
The products and applications illustrated herein (including transformer construction and circuits external to the products) may be
covered by one or more U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned to Power
Integrations. A complete list of Power Integrations patents may be found at www.power.com. Power Integrations grants its customers
a license under certain patent rights as set forth at http://www.power.com/ip.htm.
Life Support Policy
POWER INTEGRATIONS PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF POWER INTEGRATIONS. As used herein:
1. A Life support device or system is one which, (i) is intended for surgical implant into the body, or (ii) supports or sustains life, and (iii)
whose failure to perform, when properly used in accordance with instructions for use, can be reasonably expected to result in
significant injury or death to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to
cause the failure of the life support device or system, or to affect its safety or effectiveness.
The PI logo, TOPSwitch, TinySwitch, LinkSwitch, LYTSwitch, InnoSwitch, DPA-Switch, PeakSwitch, CAPZero, SENZero, LinkZero,
HiperPFS, HiperTFS, HiperLCS, Qspeed, EcoSmart, Clampless, E-Shield, Filterfuse, FluxLink, StakFET, PI Expert and PI FACTS are
trademarks of Power Integrations, Inc. Other trademarks are property of their respective companies. ©2014, Power Integrations, Inc.
World Headquarters
5245 Hellyer Avenue
San Jose, CA 95138, USA.
Main: +1-408-414-9200
Customer Service:
Phone: +1-408-414-9665
Fax: +1-408-414-9765
e-mail: usasales@power.com
China (Shanghai)
Rm 2410, Charity Plaza, No. 88
North Caoxi Road
Shanghai, PRC 200030
Phone: +86-21-6354-6323
Fax: +86-21-6354-6325
e-mail: chinasales@power.com
China (Shenzhen)
17/F, Hivac Building, No. 2, Keji
Nan 8th Road, Nanshan District,
Shenzhen, China, 518057
Phone: +86-755-8672-8689
Fax: +86-755-8672-8690
e-mail: chinasales@power.com
Germany
Lindwurmstrasse 114
80337 Munich
Germany
Phone: +49-895-527-39110
Fax: +49-895-527-39200
e-mail: eurosales@power.com
India
#1, 14th Main Road
Vasanthanagar
Bangalore-560052 India
Phone: +91-80-4113-8020
Fax: +91-80-4113-8023
e-mail: indiasales@power.com
Italy
Via Milanese 20, 3rd. Fl.
20099 Sesto San Giovanni (MI)
Italy
Phone: +39-024-550-8701
Fax: +39-028-928-6009
e-mail: eurosales@power.com
Japan
Kosei Dai-3 Bldg.
2-12-11, Shin-Yokohama,
Kohoku-ku
Yokohama-shi Kanagwan
222-0033 Japan
Phone: +81-45-471-1021
Fax: +81-45-471-3717
e-mail: japansales@power.com
Korea
RM 602, 6FL
Korea City Air Terminal B/D, 159-6
Samsung-Dong, Kangnam-Gu,
Seoul, 135-728, Korea
Phone: +82-2-2016-6610
Fax: +82-2-2016-6630
e-mail: koreasales@power.com
Singapore
51 Newton Road
#19-01/05 Goldhill Plaza
Singapore, 308900
Phone: +65-6358-2160
Fax: +65-6358-2015
e-mail: singaporesales@power.com
Taiwan
5F, No. 318, Nei Hu Rd., Sec. 1
Nei Hu Dist.
Taipei 11493, Taiwan R.O.C.
Phone: +886-2-2659-4570
Fax: +886-2-2659-4550
e-mail: taiwansales@power.com
UK
First Floor, Unit 15, Meadway
Court, Rutherford Close,
Stevenage, Herts. SG1 2EF
United Kingdom
Phone: +44 (0) 1252-730-141
Fax: +44 (0) 1252-727-689
e-mail: eurosales@power.com
Power Integrations Worldwide Sales Support Locations
Revision Notes Date
A Initial Release. 11/13
B LYT4x27E, LYT4x28E – updated / added parameters: ICH1, ICH2, VV, IV(SC), and ILIMIT(F). 03/11/14
CUpdated ICH1 and ICH2, VBP(SHUNT), IOV, VV, IV(SC), IFB(SKIP), IFB(SC), ILIMIT(R), RDS(ON), Duty Cycle Reduction, Thermal Shutdown Temperature
and Hysteresis parameters per PCN-14441. 11/11/14
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Power Integrations:
LYT4217E LYT4216E LYT4315E LYT4212E LYT4214E LYT4313E LYT4213E LYT4314E LYT4316E LYT4215E
LYT4211E LYT4311E LYT4312E LYT4317E LYT4218L LYT4218E LYT4318E LYT4318L LYT4222E LYT4316L
LYT4223E LYT4217L LYT4313L LYT4314L LYT4326E LYT4321E LYT4323E LYT4317L LYT4211L LYT4214L
LYT4216L LYT4212L LYT4225E LYT4311L LYT4324E LYT4215L LYT4312L LYT4315L LYT4226E LYT4213L
LYT4224E LYT4221E LYT4322E LYT4325E LYT4228E3 LYT4327E3 LYT4328E3 LYT4227E3 LYT4213E2
LYT4218E2 LYT4222E3 LYT4325E3 LYT4212E2 LYT4216E2 LYT4313E2 LYT4215E2 LYT4221E3 LYT4225E3
LYT4317E2 LYT4214E2 LYT4217E2 LYT4226E3 LYT4326E3 LYT4323E3 LYT4315E2 LYT4324E3 LYT4312E2
LYT4316E2 LYT4322E3 LYT4211E2 LYT4321E4 LYT4223E3 LYT4224E3 LYT4311E2 LYT4318E2 LYT4314E2