Signal Relays Telecom-, Signal- and RF Relays AXICOM Cradle Relay Accessories and Mounting Sockets for cradle relays in 2 different versions n Sockets with hand solder terminals n Sockets with PCB terminals n Available in 3 different sizes Technical Data Technical Data (continued) Sizes Hand Solder Terminals PCB Terminals ROHS compliant (Directive 2002/95/EC) as per product date code 050 Sockets with hand solder terminals Weight: size I / II / III approx. 3.5 / 4.5 / 5.5 g Sockets with PCB terminals Weight: size I / II / III approx. 4.5 /5.5 / 6.5 g Terminal material CuSn8 FB 390 plated with min. 3rm silver or min. 1 m gold Socket material hand solder terminals Phenolformaldehyde type 31 (DIN 7708, part 2) Socket material PCB terminals Makrolom (polycarbonate) Maximum continuous current at 70C 5A Size I Size I Size II Size II Size III Size III 07-2012, Rev. 0712 www.te.com (c) 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. 1 Signal Relays Telecom-, Signal- and RF Relays AXICOM Cradle Relay Accessories and Mounting (Continued) Dimensions Socket Dimension a Size I Size II Size III 26.6mm 32.5mm 38mm Sockets with hand solder terminals with hold-down spring for cradle relays N, S and P Sockets with PCB terminals with hold-down spring for cradle relay W Ordering Code*) Version Size Ordering Code Part Number for printed circuit mounting, terminals silver-plated with earth terminal I II III V23154-Z1001 V23154-Z1002 V23154-Z1028 1393824-1 9-1393809-1 1-1393824-0 for solder terminals, hand solder terminals, silver-plated I II III V23154-Z1005 V23154-Z1006 V23154-Z1015 1393824-4 1393824-5 1393824-8 for cradle relays N, S and P I II III V23154-Z1021 V23154-Z1022 V23154-Z1034 1393827-1 1393827-2 1393760-2 for cradle relay W I II V23154-Z1023 V23154-Z1024 1393827-3 1393760-1 Sockets Hold-down springs *) Please note that hold down springs have to be ordered separately. 2 07-2012, Rev. 0712 www.te.com (c) 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. Signal Relays Telecom-, Signal- and RF Relays AXICOM Cradle Relay Accessories and Mounting (Continued) Dimensions Minimum spacings between sockets Socket Size I Size II Size III Dimension a and b 27mm 33mm 39mm Dimension c 42mm 48mm 54mm with hold-down spring for cradle relays N, S and P for cradle relay P Relays oriented in the same direction a Relays oriented inversely to each other When mounting cradle relay P consideration should be given to magnetic fields. Strong DC magnetic fields, possibly caused by adjacent relays,and large iron masses are the most common causes of interference. Experience has shown that under normal operating conditions the minimum spacings specified for cradle relay P are sufficient to prevent cross interference. Mounting hole layout for cradle relays and sockets with hand solder terminals with hold-down spring for cradle relays N, S and P Size I Size II Size III *) This hole is omitted when mounting hole layouts is intended for the socket 07-2012, Rev. 0712 www.te.com (c) 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. 3 Signal Relays Telecom-, Signal- and RF Relays AXICOM Cradle Relay Accessories and Mounting (Continued) Fixing of the socket AM 2.5x ... DIN 84 (Screw length = Dimension a + 3.5 mm) 2.7 DIN 433 BM 2.5 DIN 439 Direct mounting of relays without socket requires a fixing nut M2.5 DIN 934-m6AU. Ordering code: D00934-A0025-S001 Earth spring Dimensions Mounting hole layout for sockets with PCB terminals View on the terminals, basic grid 2.5mm according to EN 60097 M = Earth terminal a) Hole for mechanical armature actuation, if required b) Hole for the socket mounting with screw M1.6 Fixing of the socket AM 1.6x ... DIN 84 (Screw length = Dimension a + 7.5 mm) 1.7 DIN 433 BM 1.6 DIN 439 4 07-2012, Rev. 0712 www.te.com (c) 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change.