AXICOM
Signal Relays
Telecom-, Signal- and RF Relays
Cradle Relay Accessories and Mounting
Sizes Hand Solder Terminals PCB Terminals
Size I Size I
Size III Size III
Size II Size II
Sockets for cradle relays in 2 different versions
n Sockets with hand solder terminals
n Sockets with PCB terminals
n Available in 3 different sizes
Technical Data
ROHS compliant (Directive 2002/95/EC) as per product date code 050
Sockets with hand solder terminals
Weight: size I / II / III approx. 3.5 / 4.5 / 5.5 g
Sockets with PCB terminals
Weight: size I / II / III approx. 4.5 /5.5 / 6.5 g
Terminal material
CuSn8 FB 390 plated with min.
3µrm silver or min. 1 µm gold
Technical Data (continued)
Socket material hand solder terminals
Phenolformaldehyde type 31
(DIN 7708, part 2)
Socket material PCB terminals
Makrolom (polycarbonate)
Maximum continuous current at 70°C 5 A
07-2012, Rev. 0712
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
2
AXICOM
Signal Relays
Telecom-, Signal- and RF Relays
Cradle Relay Accessories and Mounting (Continued)
Sockets with hand solder terminals
Dimensions
Sockets with PCB terminals
with hold-down spring for cradle relays N, S and P
with hold-down spring for cradle relay W
Socket Size I Size II Size III
Dimension a 26.6mm 32.5mm 38mm
Version Size Ordering Code Part Number
Sockets
for printed circuit mounting,
terminals silver-plated
with earth terminal
I
II
III
V23154-Z1001
V23154-Z1002
V23154-Z1028
1393824-1
9-1393809-1
1-1393824-0
for solder terminals,
hand solder terminals, silver-plated
I
II
III
V23154-Z1005
V23154-Z1006
V23154-Z1015
1393824-4
1393824-5
1393824-8
Hold-down springs
for cradle relays N, S and P I
II
III
V23154-Z1021
V23154-Z1022
V23154-Z1034
1393827-1
1393827-2
1393760-2
for cradle relay W I
II
V23154-Z1023
V23154-Z1024
1393827-3
1393760-1
*) Please note that hold down springs have to be ordered separately.
Ordering Code*)
07-2012, Rev. 0712
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
3
AXICOM
Socket Size I Size II Size III
Dimension a and b 27mm 33mm 39mm
Dimension c 42mm 48mm 54mm
Signal Relays
Telecom-, Signal- and RF Relays
Cradle Relay Accessories and Mounting (Continued)
Dimensions
Minimum spacings between sockets
with hold-down spring for cradle relays N, S and P for cradle relay P
Relays oriented in the same direction
Relays oriented inversely to each other
When mounting cradle relay P consideration should be
given to magnetic fields. Strong DC magnetic fields, possibly
caused by adjacent relays,and large iron masses are the
most common causes of interference. Experience has
shown that under normal operating conditions the minimum
spacings specified for cradle relay P are sufficient to prevent
cross interference.
Mounting hole layout for cradle relays and sockets with hand solder
terminals
with hold-down spring for cradle relays N, S and P
Size I Size II Size III
*) This hole is omitted when mounting hole layouts is intended for the socket
a
07-2012, Rev. 0712
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
4
AXICOM
Signal Relays
Telecom-, Signal- and RF Relays
Cradle Relay Accessories and Mounting (Continued)
Fixing of the socket
Direct mounting of relays without socket
requires a fixing nut M2.5 DIN 934-m6AU.
Ordering code: D00934-A0025-S001
Dimensions
Mounting hole layout for sockets with PCB terminals
View on the terminals, basic grid 2.5mm according to EN 60097
M = Earth terminal
a) Hole for mechanical armature actuation, if required
b) Hole for the socket mounting with screw M1.6
Fixing of the socket
AM 2.5x ... DIN 84
(Screw length = Dimension a + 3.5 mm)
2.7 DIN 433
BM 2.5 DIN 439
Earth spring
AM 1.6x ... DIN 84
(Screw length = Dimension a + 7.5 mm)
1.7 DIN 433
BM 1.6 DIN 439