SPECIFICATION CONTROL DRAWING 100 OHM, AWG 22, 19 STRANDS OF AWG 34, RADIO FREQUENCY, TWIN CONDUCTOR CABLE CHEMINAX 0022E0311 Date: 5-5-97 Revision: THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. CONDUCTORS AWG 22, 19 Strands of AWG 34, Tin-Coated Copper 078 DIELECTRICS Rayfoam L Colors - Tan/White SHIELD AWG 38 Tin-Coated Copper 173 JACKET 203 Thermorad Ss NO Outer jacket will be black (designated by a "-0" appended to the part number, e.g., 0022E0311-0) unless otherwise specified. Designate outer jacket color with a dash number in accordance with MIL-STD-681. Raychem CAPACITANCE - MUTUAL CHARACTERISTIC IMPEDANCE VELOCITY OF PROPAGATION ELECTRICAL CHARACTERISTICS 100 + 10 ohms, Method C at 1 MHz 13.5 pF/ft. (nominal) 75% (nominal) ADDITIONAL REQUIREMENTS ELECTRICAL CONDUCTOR RESISTANCE INSULATION RESISTANCE JACKET FLAWS SPARK TEST IMPULSE TEST VOLTAGE WITHSTAND (DIELECTRIC) ENVIRONMENTAL AGING STABILITY FLAMMABILITY HEAT SHOCK LOW TEMPERATURE- COLD BEND VOLTAGE WITHSTAND (POST ENVIRONMENTAL) PHYSICAL INSULATION (DIELECTRIC) (Prior to Cabling) ELONGATION TENSILE STRENGTH JACKET ELONGATION TENSILE STRENGTH JACKET THICKNESS SHIELD COVERAGE WEIGHT Raychem Corporation 300 Constitution Orve Menio Park, Cahfornia 94025 1-800-2 Raychem Fax 1-415-361-6297 14.75 ohms/1000 ft. (nominal) 10,000 megohms (minimum) for 1000 ft. 1.0kV(rms),60Hz 6.0 kV (peak) 1000 voits (rms) (minimum) 135C/-55C/5.50 inch mandre Method C : . 225C -55C/5.50 inch mandrel 1000 volts (rms), 1 minute 50% (minimum) 1000 Ibf/in? (minimum) 250% (minimum) 2000 Ibf/in? (minimum) .015 inch (nominal) 90% (minimum) 20.0 Ibs/1000 ft. (nominal) THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HERIN. REFERENCE DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID