ACDC 3060 Watts AFM Series xppower.com * Energy Efficiency Level V * CEC2008 & EISA2007 Compliant * IT & Medical Approvals * China Compulsory Certification (CCC) Qualified * Optional Class II Versions * Optional White Case Versions * 3 Year Warranty Specification Input General * 80-264 VAC, derate output power 25% <90 VAC Input Frequency * 47-63 Hz Input Current * AFM30: 0.8 A rms at 115VAC, AFM45: 1.2 A rms at 115VAC, AFM60: 1.5 A rms at 115 VAC Power Factor * EN61000-3-2, class A Earth Leakage Current * 150 A max at 264 VAC/60 Hz No Load Input Power * AFM30/45: <0.3 W, AFM60: <0.5 W Input Voltage Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Hold Up Time Line Regulation Load Regulation Transient Response * * * * * * * * * Ripple & Noise * Overvoltage Protection * Overload Protection * Short Circuit Protection * Temperature * Coefficient See table Not user-adjustable 2% No minimum load required 3 s max at 115 VAC 8 ms minimum at 115 VAC 1.0% maximum 2.5% maximum 4% max. deviation, recovery to within 1% in 500 s for a 25% load change 1% max pk-pk (1) 110-170% Vnom, recycle input to reset AFM45/60: 110-170%, AFM30: 110-220%, auto recovery Trip and restart (hiccup mode) 0.04%/C Efficiency Energy Efficiency Isolation Switching Frequency Power Density MTBF * See table * Level V * 4000 VAC Input to Output, 2 x MOPP 1500 VAC Input to Ground, 1 x MOPP* Output 0 V is electrically connected to Input Ground*. *Not C8 version. * 30/45 W: 58 kHz typ., 60 W: 52 kHz typ. * AFM30: 2.8 W/In3, AFM45: 4.2 W/In3, AFM60: 3.76 W/In3 * >250 kHrs to MIL-HDBK-217F at 25 C, GB, full load Environmental Operating Temperature * 0 C to +60 C, derate from 100% power at +40 C to 60% power at +60 C Operating Humidity * 10-95% RH, non-condensing Storage Temperature * -40 C to +80 C Operating Altitude * 2000 m Shock * 30 g, 10 ms on 3 axes Vibration * 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals * EN55011/22/FCC Class B conducted, EN55011/22/FCC Class B radiated * EN61000-3-2, Class A * EN61000-3-3 * EN61000-4-2, 6 kV contact and 8 kV air discharge * EN61000-4-3, 3 V/m Perf Criteria A * EN61000-4-4, level 3 Perf Criteria A (7) * EN61000-4-5, installation class 3 Perf Criteria A * EN61000-4-6, 3 Vrms Perf Criteria A * EN61000-4-8, 3 A/m, Perf Criteria A * EN61000-4-11, 30% for 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf A, A, A, B (8) * EN60950-1, UL60950-1, IEC60950-1 EN60601-1 (3rd Ed.), UL60601-1 (2nd Ed.), IEC60601-1 (3rd Ed.) China Compulsory Certification (CCC) Qualified. Output Power 30 30 30 30 48 48 48 48 60 60 60 60 Output Voltage(6) W W W W W W W W W W W W 12 15 18 24 12 15 18 24 12 15 18 24 Output Current V V V V V V V V V V V V 2.50 2.00 1.67 1.25 4.00 3.20 2.67 2.00 5.00 4.00 3.34 2.50 A A A A A A A A A A A A Efficiency(7) Model Number(3,4,5) 87.9% 88.4% 87.6% 88.0% 87.7% 88.0% 87.2% 87.7% 87.3% 88.2% 88.3% 87.8% AFM30US12 AFM30US15 AFM30US18 AFM30US24 AFM45US12 AFM45US15 AFM45US18 AFM45US24 AFM60US12 AFM60US15 AFM60US18 AFM60US24 Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 F tantalum and 0.1 F ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 3. For optional Class II versions with a polarised IEC320-C8 inlet, add suffix `C2' to the model number, e.g. AFM60US24C2. 4. For alternative IEC320-C6 inlet, add suffix `C6' to the model number eg. AFM60US24C6. 5. 6. 7. 8. 9. For white case version add suffix -W. MOQ applies, contact sales for details. Other output voltages are available, contact sales for details. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. A minimum load of 1% is required to meet performance criteria A. Performance criteria given for high line input. Mechanical Details 37.4 2 (950 50) 1.31 (33.4) Output Plug: o 5.5 x o 2.5 x 11.0 mm inner positive A Optional AC Cable Restraint (see note 8 below) 0.53 (13.7) 0.66 (16.8) 0.07 (1.8) 80 1 1.4 .0) (36 C 0.68 (17.3) 0.17 (4.4) B A B C AFM30 & 45 AFM60 4.76 (121.0) 1.97 (50.0) 1.21 (30.8) 4.92 (125.0) 2.44 (62.0) 1.33 (34.0) Standard AC INLET IEC-320-C14 Optional C6 AC INLET IEC-320-C6 Optional C8P AC INLET IEC-320-C8P Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: AFM45: 0.56 lbs (256 g), AFM60: 0.78 lbs (360 g) approx. 3. Case material is PC Class 94 V-0. 4. Output Lead: UL1185, 16 AWG 5. For European mains lead order part EU-MAINS-IEC for C14 versions, EU-MAINS-5 for C6 versions or EU-MAINS-8 for C8 versions. 6. For UK mains lead order part UK-MAINS-IEC for C14 versions, UK-MAINS-5 for C6 versions or UK-MAINS-8 for C8 versions. 7. For US mains lead order part US-MAINS-IEC for C14 versions, US-MAINS-5 for C6 versions or US-MAINS-8 for C8 versions. 8. For optional AC Cable Restraint on the standard input version add suffix ``A' to the model number e.g. AFM60US24A. AC Mains Lead must be Interpower Corporation, part number 70006020300. Option AC Cable Restraint is not available on IEC320-C6 inlet or Class II versions. 9. The standard C7 cable fits the C8P connector. 04-Aug-14 ACDC AFM3060 Models and Ratings