C25 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com
Inductive
Sensors
For detailed sensor specifications see Section A.
Normally Closed versions available upon request, consult factory.
Housing Style Part Number ID Number Features
Sensing
Range (mm)
Output
8 mm - Nonembeddable, Miniature
Threaded, eurofast ®Quick Disconnect
Ni 4-EG08K-AG41X-H1341 S4561011 Short Barrel 4
2-Wire DC
Ni 4-EG08K-AG41X-H1341/S1589 S4561090 Weldguard 4
Ni 3-EG08K-AN6X-H1341 S4669760 Short Barrel 33-Wire DC
NPN
Ni 3-EG08K-AP6X-H1341 S4669660 Short Barrel 33-Wire DC
PNP
Ni 3-EG08K-Y1-H1341 S1003720 Short Barrel 32-Wire DC
NAMUR
Ni 3-EG08K-Y1X-H1341 S1003704 3
8 mm - Nonembeddable, Miniature
Threaded, eurofast Quick Disconnect
Ni 4-EG08-AG41X-H1341 S4561001 4
2-Wire DC
Ni 4-EG08-AG41X-H1341/S1589 S4561091 Weldguard 4
Ni 3-EG08-AN6X-H1341 S4602860 3
3-Wire DC
NPN
Ni 3-EG08-AN6X-H1341/S1589 S4602889 Weldguard 3
Ni 4U-EG08-AN6X-H1341 S4600650 Uprox 4
Ni 3-EG08-AP6X-H1341 S4602760 3
3-Wire DC
PNP
Ni 3-EG08-AP6X-H1341/S1589 S4602799 Weldguard 3
Ni 4U-EG08-AP6X-H1341 S4600640 Uprox 4
Ni 3-EG08-Y1-H1341 S1003730 3 2-Wire DC
NAMUR
8 mm - Nonembeddable, Miniature
Threaded, eurofast Quick Disconnect
Ni 2-G08M-AN7-H1341 S4703300 TTL Compatible 2
3-Wire DC
NPN
Ni 2-G08M-AN7X-H1341 S4703700 TTL Compatible 2
8 mm - Nonembeddable, Miniature
Threaded, eurofast Quick Disconnect
Ni 2-G08-AN6X-H1341 S4603300 2
3-Wire DC
NPN
Ni 3-G08-AN6X-H1341 3
Ni 2-G08-AP6X-H1341 S4603200 2
3-Wire DC
PNP
Ni 3-G08-AP6X-H1341 S4602705 3
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com C26
Industrial
Automation
Barrels
For material descriptions see page A34.
Industrial
Automation
TURCK mold-on connectors available
on all cable sensors. See page A5.
Voltage
Switching
Freq. (Hz)
Operating
Current (mA)
Operating
Temp. (°C)
Protection
Housing
Face
Power LED
Output LED
Mating
Cordset
Wiring
Diagram #
Wiring Diagrams
10-65 VDC
1000 100 -25 to +70 IP 67 SS PA 12 N/A YE RKV 4.2T-* 1
1000 100 -25 to +70 IP 67 SS WG N/A RKG 4.2T-*/S600 1
10-30 VDC
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 2
10-30 VDC
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 3
5-30 VDC
5000 Remote -25 to +70 IP 67 SS PA 12 N/A N/A RK 4.21T-* 4
5000 Remote -25 to +70 IP 67 SS PA 12 N/A N/A RK 4.21T-* 4
10-65 VDC
1000 100 -25 to +70 IP 67 SS PA 12 N/A YE RK 4.2T-* 1
1000 100 -25 to +70 IP 67 SS WG N/A YE RK 4.2T-* 1
10-30 VDC
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 2
3000 150 -25 to +70 IP 67 SS WG N/A YE RKG 4T-*/S600 2
2000 150 -30 to +85 IP 68 SS PA 12 N/A YE RK 4T-* 2
10-30 VDC
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 3
3000 150 -25 to +70 IP 67 SS WG N/A YE RKG 4T-*/S600 3
2000 150 -30 to +85 IP 68 SS PA 12 N/A YE RK 4T-* 3
5-30 VDC 5000 Remote -25 to +70 IP 67 SS PA 12 N/A N/A RK 4.21T-* 4
10-30 VDC
2000 150 -25 to +70 IP 67 SS PA 12 N/A N/A RK 4T-* 2
2000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 2
10-30 VDC
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 2
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 2
10-30 VDC
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 3
3000 150 -25 to +70 IP 67 SS PA 12 N/A YE RK 4T-* 3
* Length in meters
Diagram 3
Diagram 4
Diagram 1
Diagram 2