Ideal Power Ltd
Ideal Power, Ideal House, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, EX32 7NZ, England, UK
Tel: +44 (0) 845 260 3400 Email: sales@idealpower.co.uk Web: www.idealpower.co.uk
The burn-in test will be performed at least 2 hours at 40 centigrade degrees
When the operation is compling with this specification, the switching power
supply's MTBF will be 50,000 hours at 25 centigrade degrees.
The switching power supply can withstand the following environmental conditions:
ISSUED DATE:
REV: (A1)
PAGE NO. :
14.1 Burn-in
under full load condition.
14.2 MTBF
15.0 SAFETY
13.0 EMI / EMC
Relative Humidity: 10% ~ 95%
Relative Humidity: 10%~95%
12.1 Storage Temperature:-20
℃
~ +70
℃
12.2 Operation
14.0 RELIABILITY AND QUALITY CONTROL
Temperature:0°C~40°C
12.0 ENVIRONMENTAL CONDITIONS
PART NO. :
MODEL NO. : HK-AB-120A250-CP
HKSC-130743 2013.06.07
4 OF 12
DESCRIPTION : I.T.E. POWER SUPPLY
The switching power supply has approved by the following safety standards:
The switching power supply has approved by the following standards:
(1)EN55022(EN61000-3-2.EN61000-3-3)
(2)EN55024(IEC61000-4-2.IEC61000-4-3.IEC61000-4-4.
IEC61000-4-6.IEC61000-4-8.IEC61000-4-11.)
BS EN60950-1:2006+A1+A12
UL60950-1 2nd Edition ,2007-03-27 CSA C22.2 NO.60950-1-07,
2nd Edition.2007-03
FCC PART 15B
AS/NZS 60950.1:2011
AS/NZS 55022/55024
EN 60950-1:2006+A11+A1+A12
Ideal Power, 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England EX32 7NZ
Web: www.idealpower.co.uk email: sales@idealpower.co.uk TEL +44 (0) 845 2603400 Fax +44 (0) 845 2603401
J55022(H20)
Page 5 of 12