1
Power Entry Modules with Line Filter 5130
www.schurter.com/PG06
Connectors
IEC Appliance Inlet C20 with Filter, ECO design, front or rear side Mounting
Screw-on or rivet mounting from front or rear side
Screw-On Version
Screw-on mounting from rear side, integrated
thread
Screw-On Version
Snap-in mounting from front side
Standard- or Medical-Filter
C20
70° C
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions:
Appliance Inlet Protection class I, Line filter in standard and medical
version
- Quick connect terminals
Approvals
- VDE Certificate Number: 104884
- UL File Number: E72928
Characteristics
- Optimal shielding due to completely closed filter case, unpotted
Suitable for assembly in metal plated plastic housings
- Version with class X1 and X2 (standard version) capacitors
- Universal line filter for standard applications
Designed for standard and medical applications
- Suitable for use in equipment according to IEC 60950
Other versions on request
- Solder terminals
- Medical version M80
- Capacity CX 330 nF
References
Fits to type: Cord Sets 15 A; 4790; 4795 Cord Sets 15 A; 0104; 010
4U; 1651; 1652; 1654; 4790; 4795
Alternative: Standard version
Alternative: version without line filter 4793
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Wire Harnessing, Mounting instruction, Detailed
request for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC 16 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA 20 A @ Ta 40 °C / 250 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Impulse Withstand Voltage > 2.5 kV between L-N (CX2)
> 4 kV between L-N (CX1)
> 5 kV between L/N-PE (Cy2)
voltage (1.2/50 μs)
Allowable Operation Temp. -25 °C to 85 °C
Climatic Category 25/085/21 acc. to IEC 60068-1
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminal 6.3 x 0.8 mm
Panel Thickness s Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
(all steps with one variant)
Material: Housing Themoplast / steel tin-plated, black /
metallic, UL 94V-0
Appliance-Inlet/-Outlet C20 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Line Filter Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical Details
MTBF > 3'000'000 h acc. to MIL-HB-217 F