Data sheet Z-series ZDU 16 Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Product image Spring connection with tension clamp Technology Tension clamp technology is a universal contact system for all common conductor connection types. Its fantastic level of flexibility makes the tension clamp a profitable alternative connection. General ordering data Type Order No. Version GTIN (EAN) Qty. ZDU 16 1745230000 Feed-through terminal, Tension-clamp connection, 16 mm, 1000 V, 76 A, dark beige 4008190996765 25 pc(s). Creation date July 11, 2019 6:37:38 AM CEST Catalogue status 07.06.2019 / We reserve the right to make technical changes. 1 Data sheet Z-series ZDU 16 Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights Width Height Depth Depth including DIN rail 12.1 mm 82.5 mm 50.5 mm 51.5 mm Width (inches) Height (inches) Depth (inches) Net weight 0.476 inch 3.248 inch 1.988 inch 36.752 g For operating temperature range see EC Design Test Certificate / IEC ExCertificate of Conformity 10 C -50 C Storage temperature, max. Storage temperature Continuous operating temp., max. 40 C 10 C...40 C 120 C Wemid V-0 Colour dark beige KEMA99ATEX5514U 550 V 16 mm 68 A For operating temperature range see EC Design Test Certificate / IEC ExCertificate of Conformity II 2 G D Certificate No. (IECEX) Current (ATEX) Max. voltage (IECEX) Wire cross section max. (IECEX) Marking EN 60079-7 IECEXULD15.0008U 66 A 690 V 25 mm Tension-clamp connection, for plug-in cross-connector, One end without connector 1 1 No End cover plate required No. of clamping points per level Levels cross-connected internally Rail Yes 2 No TS 35 Yes right Number of similar terminals Type of mounting 1 Snap-on 200039-1152892 65 A 600 V 14 AWG Current size B (CSA) Voltage size B (CSA) Wire cross section max. (CSA) 65 A 600 V 4 AWG Temperatures Operating temperature range Storage temperature, min. Continuous operating temp., min. Material data Material UL 94 flammability rating Rating data IECEx/ATEX Certificate No. (ATEX) Max. voltage (ATEX) Wire cross section max. (ATEX) Current (IECEX) Operating temperature range Ex 2014/34/EU label Ex eb II C Gb System specifications Version Number of levels Number of potentials per tier PE connection Additional technical data Explosion-tested version Open sides CSA rating data Certificate No. (CSA) Current size C (CSA) Voltage size C (CSA) Wire cross section min. (CSA) Creation date July 11, 2019 6:37:38 AM CEST Catalogue status 07.06.2019 / We reserve the right to make technical changes. 2 Data sheet Z-series ZDU 16 Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Conductors for clamping (rated connection) Blade size Clamping range, min. 1.0 x 5.5 mm 1.5 mm Connection cross-section, stranded, min. 1.5 mm Gauge to IEC 60947-1 A7 Stripping length 18 mm Wire connection cross section AWG, max. AWG 4 Wire connection cross section, finely stranded, max. 16 mm Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 1.5 mm Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 1.5 mm Wire connection cross-section, solid core, max. 16 mm Clamping range, max. Connection cross-section, stranded, max. Connection direction Number of connections Type of connection Wire connection cross section AWG, min. Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. Wire connection cross-section, finely stranded, min. Wire connection cross-section, solid core, min. 25 mm 25 mm top 2 Tension-clamp connection AWG 14 16 mm 16 mm 1.5 mm 1.5 mm Dimensions TS 35 offset 42 mm Rating data Rated cross-section Rated current Standards Rated impulse withstand voltage 16 mm 76 A IEC 60947-7-1 8 kV Rated voltage Current at maximum wires Volume resistance according to IEC 60947-7-x Pollution severity 1,000 V 98 A 0.42 m 3 UL rating data Certificate No. (UR) Conductor size Factory wiring min. (UR) Conductor size Field wiring min. (UR) Voltage size C (UR) E60693 14 AWG 14 AWG 600 V Conductor size Factory wiring max. (UR) 4 AWG Conductor size Field wiring max. (UR) 4 AWG Current size C (UR) 65 A EC000897 EC000897 30-21-18-11 27-14-11-20 27-14-11-20 27-14-11-20 ETIM 4.0 ETIM 6.0 eClass 5.1 eClass 7.1 eClass 9.0 Classifications ETIM 3.0 ETIM 5.0 UNSPSC eClass 6.2 eClass 8.1 eClass 9.1 EC000897 EC000897 27-14-11-20 27-14-11-20 27-14-11-20 Creation date July 11, 2019 6:37:38 AM CEST Catalogue status 07.06.2019 / We reserve the right to make technical changes. 3 Data sheet Z-series ZDU 16 Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Approvals Approvals ROHS Conform Downloads Approval/Certificate/Document of Conformity Brochure/Catalogue Engineering Data Engineering Data User Documentation Attestation of Conformity IECEx Certificate ATEX Certificate DE_PT1101_20160418_1163_ISSUE01.pdf CAT 1 TERM 16/17 EN EPLAN, WSCAD, Zuken E3.S STEP Cross Connection Guide StorageConditionsTerminalBlocks Safety note Safety notice Safety Information Creation date July 11, 2019 6:37:38 AM CEST Catalogue status 07.06.2019 / We reserve the right to make technical changes. 4 Data sheet Z-series ZDU 16 Drawings Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Creation date July 11, 2019 6:37:38 AM CEST Catalogue status 07.06.2019 / We reserve the right to make technical changes. 5