1power.pulseelectronics.com P821. F (07/18) http://www.power.pulseelectronics.com/contact
SMT Power Inductors
High Current Molded Power Inductor - PA4349.XXXANLT Series
Height: 13.0mm Max
Footprint: 24.0mm x 22.3mm Max
Current Rating: up to 62.0A
Inductance Range: 1.5uH to 100uH
Shielded construction and compact design
High current, low DCR, and high efciency
Minimized acoustic noise and minimized leakage ux
Electrical Specifications @ 25°C - Operating Temperature -55°C to +155°C
Part
Number
Inductance
100KHz, 1V
Rated
Current
DC Resistance Saturation
Current
TYP. MAX.
uH±20% A mΩmΩA
PA4349.152ANLT 1.5 62 11.15 52
PA4349.202ANLT 2 60 1.02 1.2 50
PA4349.222ANLT 2.2 58 1.05 1.25 48
PA4349.302ANLT 3 51 1.42 1.64 44
PA4349.332ANLT 3.3 49 1.5 1.75 41
PA4349.472ANLT 4.7 47 1.9 2.2 38
PA4349.682ANLT 6.8 40 2.7 3.1 36
PA4349.103ANLT 10 33 3.8 4.15 28
PA4349.153ANLT 15 26 5.1 6.12 23
PA4349.223ANLT 22 22 9.2 11 15
PA4349.233ANLT 23 22 9.2 11 15
PA4349.333ANLT 33 19 13.5 15.4 12
PA4349.473ANLT 47 17 17.3 20.8 12
PA4349.683ANLT 68 14 26.2 29.5 12
PA4349.753ANLT 75 13 27.5 31.6 10.5
PA4349.823ANLT 82 12 31 34.2 9
PA4349.104ANLT 100 11 36 40 9
Notes:
1. Actual temperature of the component during system operation (ambient plus
temperature rise) must be within the standard operating range.
2. The saturation current is the current at which the initial inductance drops approxi-
mately 30% at the stated ambient temperature. This current is determined by placing
the compnent in the specified ambient environment and applying a short duration
pulse current (to eliminate self-heating eect) to the component.
3. The rated current is the DC current required to raise the component temperature by
approximately 40�C. Take note that the components’ performanc varies depending
on the system condition. It is suggested that the component be tested at the system
level, to verify the temperature rise of the component during system operation.
4. The part temperature (ambient+temp rise) should not exceed 155�C under worst
case operating conditions. Circuit design, PCB trace size and thickness, airflow and
other cooling provisions all aect the part temperature. Part temperature should be
verified in the end application.
5. Parts shown in bold are standard catalog parts and are available through sample
stock and distribution. Parts in lighter font are available but are not necessarily held
in sample stock or distribution and lead times may be longer. Please contact Pulse
for availablity.