Original instructions Smile Emergency stop with indication ABB AB / Jokab Safety Varlabergsvagen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage Read and understand this document Please read and understand this document before using the products. Please consult your ABB/JOKAB SAFETY representative if you have any questions or comments. WARRANTY ABB/JOKAB SAFETY's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by ABB/JOKAB SAFETY. ABB/JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED USE. ABB/JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. LIMITATIONS OF LIABILITY ABB/JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted. IN NO EVENT SHALL ABB/JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS ABB/JOKAB SAFETY'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE ABB/JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, ABB/JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE ABB/JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA While every effort has been taken to ensure the accuracy of the information contained in this manual ABB/JOKAB SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and improvements without notice. Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of ABB/JOKAB SAFETY'S test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the ABB/JOKAB SAFETY Warranty and Limitations of Liability. 2TLC172171M0201, rev. B 2012-01-18 2 www.abb.com/lowvoltage Table of Contents 1 Introduction ......................................................................................................................................... 4 Scope ................................................................................................................................................................ 4 Audience ........................................................................................................................................................... 4 Prerequisites...................................................................................................................................................... 4 Special notes ..................................................................................................................................................... 4 2 Overview .............................................................................................................................................. 5 General description ............................................................................................................................................ 5 Safety regulations .............................................................................................................................................. 5 3 Connections ........................................................................................................................................ 6 Connection examples......................................................................................................................................... 7 4 Installation and maintenance ........................................................................................................... 11 Installation precautions .................................................................................................................................... 11 Maintenance .................................................................................................................................................... 11 5 Operation ........................................................................................................................................... 12 LED indication.................................................................................................................................................. 12 6 Model overview .................................................................................................................................. 13 Accessories ..................................................................................................................................................... 13 7 Technical data ................................................................................................................................... 14 Dimensions ...................................................................................................................................................... 15 8 EC Declaration of conformity ........................................................................................................... 16 2TLC172171M0201, rev. B 2012-01-18 3 www.abb.com/lowvoltage 1 Introduction Scope The purpose of these instructions is to describe the emergency stop Smile and to provide the necessary information required for installation and operation. Audience This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: Basic knowledge of ABB/Jokab Safety products. Knowledge of machine safety. Special notes Pay attention to the following special notes in the document: Warning! Danger of severe personal injury! An instruction or procedure which, if not carried out correctly, may result in injury to the technician or other personnel. Caution! Danger of damage to the equipment! An instruction or procedure which, if not carried out correctly, may damage the equipment. NB: Notes are used to provide important or explanatory information. 2TLC172171M0201, rev. B 2012-01-18 4 www.abb.com/lowvoltage 2 Overview General description In order to fulfil the need for a small and easy to install E-stop, Smile has been developed. The size of the device makes it possible to be installed wherever needed. With M12 connections or cable and centralized mounting holes. Smile is very easy to install, especially on aluminium extrusions. There are different versions available, either with one or two M12 connections or cable. Two M12 connectors are used to enable the connection of E-stops in series. On the top of the Smile E-stop unit, an LED indicates the status. Warning! The emergency stop Smile normally needs to be complemented with other safety functions such as interlocking guards etc. Refer to risk analysis. NB: The emergency stop shall not be used as normal stop of the machine, only in case of emergency. Safety regulations Warning! Carefully read through this entire manual before using the device. The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine directive. Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions, improper installation or handling of the device can affect the safety of people and the plant. For installation and prescribed use of the product, the special notes in the instructions must be carefully observed and the technical standards relevant to the application must be considered. In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the product, any liability is excluded. 2TLC172171M0201, rev. B 2012-01-18 5 www.abb.com/lowvoltage 3 Connections Electrical connections - Smile 1 2 2 1 2 1 5 5 3 4 4 3 4 3 Smile 10EK M12 5-pole male seen from cable side 1 2 3 4 5 M12 5-pole female seen from cable side Smile 10EA 1 2 3 4 5 Smile 12EA Smile 11EA Input M12 5-pole male 1 2 3 4 5 1 2 3 4 5 Smile 12EA 1 ) Input 1 2 ) Input 2 3 ) 0 VDC1 4 ) Output 2, feedback 5 ) Output 1, feedback Smile 10EA Smile 11EA Output 5-pole wired Smile 10EK M12 5-pole male M12 5-pole female 1 ) Brown: Input 1 4x wires 1 ) Input 1 1 ) Output 1 2 ) White: 1 ) Input 1 2 ) Input 2 2 ) Output 2 Input 2 1 1 2 ) Input 2 3 ) 0 VDC 3 ) 0 VDC Output 2 3 ) Output 2 4 ) Output 2 4 ) Input 2, feedback Output 1 4 ) Output 1 5 ) Output 1 5 ) Input 1, feedback 3 ) Blue: 0 VDC 4 ) Black: 5 ) Grey: 1. To be connected only if LED indication is required. NB: Smile 10EA/11EA/12EA can be used with any safety PLC or safety relay, but if LED indication is required the voltage over pin-1 (+) and pin-3 (-) must be between 19.2 - 28.8 VDC. Caution! When connected to an ABB/Jokab Safety safety relay (such as an RT6 or RT9) and voltage (+) is supplied from the output S13, a maximum of three Smile units may be connected in series. This must be done with caution (especially in warm environments) as this affects the heat generation within the safety relay. If more than three units are connected in series, voltage (+) should be supplied from another source (e.g. A1). 2TLC172171M0201, rev. B 2012-01-18 6 www.abb.com/lowvoltage Connection examples Connection example - Smile 10EA Smile 10EA can be connected to either Pluto or a safety relay. The connection cable exits from underneath the unit. Single channel example with LED indication. Safety category 1 A +24V 1 (+) S13 2 Safety PLC Safety relay Pluto E.g. RT6, RT9 0V A2 0V 4 S34 5 S14 I0 3 Smile 10EA Two channel example with LED indication. Safety circuit category 4 +24V (+) S13 IQ 10 A-pulse (A2) S23 1 A S34 Safety PLC 2 Safety relay Pluto E.g. RT6, RT9 0V A2 I0 S24 I1 S14 0V 3 4 5 Smile 10EA 2TLC172171M0201, rev. B 2012-01-18 7 www.abb.com/lowvoltage Connection example - Smile 11EA Smile 11EA can be connected to either Pluto or a safety relay. Connection via M12 connector. Single channel example with LED indication. Safety category 1 1 +24V A (+) S13 2 Safety PLC Safety relay Pluto E.g. RT6, RT9 0V A2 0V 3 4 S34 5 S14 I0 Smile 11EA Two channel example with LED indication. Safety circuit category 4 1 +24V (+) S13 IQ 10 A-pulse (A2) S23 S34 Safety PLC A 2 Safety relay Pluto E.g. RT6, RT9 0V A2 I0 S24 I1 S14 0V 3 4 5 Smile 11EA 2TLC172171M0201, rev. B 2012-01-18 8 www.abb.com/lowvoltage Connection example - Smile 12EA Smile 12EA can be connected to either Pluto or a safety relay. Single channel example with LED indication. Safety category 1. Connection via M12 connector + termination connector. JST2 A 1 +24V 1 (+) S13 Safety PLC Safety relay Pluto E.g. RT6, RT9 0V 0V A2 S34 I0 2 2 3 3 4 4 5 5 S14 Smile 12EA Two channel example with LED indication. Safety circuit category 4. Connection via M12 connector + termination connector. A 1 +24V (+) S13 IQ 10 A-pulse (A2) S23 S34 Safety PLC JST2 1 2 2 3 3 4 4 5 5 Safety relay Pluto E.g. RT6, RT9 0V A2 I0 S24 0V S14 I1 Smile 12EA Two channel serial connection example with LED indication. Safety circuit category 3. Connection via M12 connector + termination connector. Note that there is no termination connector for the Smile 12EA (C), this unit is being connected back to the Pluto/safety relay via a separate cable. 1 +24V (+) S13 IQ 10 A-pulse (A2) S23 S34 Safety PLC A 1 1 2 2 3 C 1 1 1 2 2 2 2 3 3 3 3 3 4 4 4 4 4 4 5 5 5 5 5 5 Safety relay Pluto E.g. RT6, RT9 0V A2 I0 S24 I1 0V S14 Smile 12EA 2TLC172171M0201, rev. B 2012-01-18 B Smile 12EA 9 Smile 12EA www.abb.com/lowvoltage Connection example - Smile 11EA & -12EA Both Smile 11EA and -12EA can be connected to either Pluto or a safety relay. Two channel example with LED indication. Safety category 3. Connection via M12 connectors. Note that there is no termination connector as the Smile 11EA (C) completes the circuit without the need for a termination connector (JST2) or return cable. 1 +24V (+) S13 IQ 10 A-pulse (A2) S23 S34 Safety PLC A 1 1 2 2 3 B 1 1 2 2 2 3 3 3 3 4 4 4 4 4 5 5 5 5 5 C Safety relay Pluto E.g. RT6, RT9 0V A2 I0 S24 I1 S14 0V Smile 12EA Smile 12EA Smile 11EA LED indication example The table shows the LED indication status of the emergency stop actuators from the connection example above. Emergency stop actuator status LED indication A B C A B C Released Released Released --- Green Green Green Released Released Pressed --- Green Green Red Released Pressed Released --- Green Red OFF Released Pressed Pressed --- Green Red OFF Pressed Released Released --- Red OFF OFF Pressed Released Pressed --- Red OFF OFF Pressed Pressed Released --- Red OFF OFF Pressed Pressed Pressed --- Red OFF OFF NB: More information about the LED indication can be found in chapter Operation. 2TLC172171M0201, rev. B 2012-01-18 10 www.abb.com/lowvoltage 4 Installation and maintenance Installation precautions First mount Smile to the surface with two M5 bolts, and then attach the M12 connection(s). Warning! All the safety functions must be tested before starting up the system. Maintenance Warning! The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the safety functions are working properly (EN 62061:2005). In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel. 2TLC172171M0201, rev. B 2012-01-18 11 www.abb.com/lowvoltage 5 Operation Warning! The maximum number of operations (cycles) for the emergency stop Smile is 6050 operations. LED indication LED LED on button Indication Description Green Safety device OK. Safety circuit closed. OFF Safety circuit interrupted (when an emergency stop actuator is pressed down, all following units in the safety circuit lose the LED function). Red Safety device actuator pressed down. Safety circuit interrupted. 2TLC172171M0201, rev. B 2012-01-18 12 www.abb.com/lowvoltage 6 Model overview Type Article number Description Smile 11EA 2TLA030051R0000 Emergency stop, red button, M12 5-pole male Smile 11EAR 2TLA030051R0100 Emergency stop, red button, M12 5-pole male, reversed Smile 12EA 2TLA030051R0200 Emergency stop, red button, M12 5-pole male, M12 5-pole female Smile 10EA 2TLA030051R0400 Emergency stop, red button, 1 m cable (5-pole) Smile 10EK 2TLA030051R0600 Emergency stop, red button, short leads (4x wires, no LED connection) Smile 11SA 2TLA030051R0900 Safety stop, black button, M12 5-pole male Smile 12SA 2TLA030051R1000 Safety stop, black button, M12 5-pole male, M12 5-pole female Smile 11SAR 2TLA030051R1100 Safety stop, black button, M12 5-pole male, reversed Smile 11EA Smile 12EA Smile 10EA Smile 10EK Smile 11EAR Accessories Type Article number Description JST2 2TLA030051R1300 Termination for Smile 12 Emergency stop sign 2TLA030054R0700 O32.5 mm, Swedish, Danish, Finnish. For reversed Smile. Emergency stop sign 2TLA030054R0800 O32.5 mm, English, French, German. For reversed Smile. JST2 Termination for Smile 12 Article number: 2TLA030051R1300 2TLC172171M0201, rev. B 2012-01-18 Emergency stop sign For reversed Smile Article number: S, D, F: 2TLA030054R0700 E, F, G: 2TLA030054R0800 13 www.abb.com/lowvoltage 7 Technical data Manufacturer Address ABB AB / JOKAB SAFETY Varlabergsvagen 11 SE-434 39 Kungsbacka Sweden Power supply Operating voltage (LED) 17-27 VDC 10 % Current consumption (LED) 15 mA Minimum current (switches) 10 mA 10 VDC/10 VAC Maximum current (switches) 2 A 24 VDC General Protection class IP65 Ambient temperature Storage: -30...+70C Operation: -10...+55C Housing material Polyamide PA66, Macromelt, polybutylenterephthalate PBT, Polypropene PP, UL 94 V0 Contact material Silver alloy, gold plated Connectors Smile 10EA: 5-pole cable, 1 m Smile 10EK: 4x wires Smile 11x*: M12 5-pole male Smile 12x*: M12 5-pole male, M12 5-pole female * - x can be all models -EA, -EAR, -SA, -SAR Size 84 x 40 x 52 (L x W x H) - see drawing Weight ~ 65 g Colour Yellow base, red or black button Actuator force (E-stop button) 22 4N Actuator travel ~ 4 mm to latch Mechanical life > 50,000 operations Impact resistance (half sinusoidal) Max. 150 m/s , pulse width 11 ms, 3-axis (as per EN IEC 60068-2-27) Vibration resistance (half sinusoidal) Max. 50m/s at 10 Hz, 10 cycles, 3-axis (as per EN IEC 60068-2-6) 2 2 Climate resistance Damp heat, cyclical 96 hours, +25C / 97%, +55C / 93% relative humidity, as per EN IEC 60068-2-30 Damp heat, sustained 56 days, +40C / 93% relative humidity, as per EN IEC 60068-2-78 Dry heat 96 hours, +70C, as per EN IEC 60068-2-2 Cooling 96 hours, -40C, as per EN IEC 60068-2-1 Salt mist 96 hours, +35C in a chemical solution with NaCl as per EN IEC 60068-2-11 2TLC172171M0201, rev. B 2012-01-18 14 www.abb.com/lowvoltage Safety / Harmonized Standards Conformity European Machinery Directive 2006/42/EC EN ISO 12100:2010, EN 954-1:1996, EN ISO 13849-1:2008/AC:2009, EN 60204-1:2007+A1, EN ISO 13850:2008 EN ISO 13849-1 Performance level: Up to PL e, category 4 B10d: 6 050 EN 954-1 Up to safety circuit category 4 Certificates Inspecta NB: A safety function with an emergency stop Smile can achieve Cat. 4/PL e according to EN 954-1/EN ISO 13849-1 only when a single Smile unit is connected to the control unit (safety-PLC or safety relay) in a dual channel configuration. Warning! The maximum number of operations (cycles) for the emergency stop Smile is 6050 operations. Dimensions Dimensions - Smile NB: All measurements in millimetres. 2TLC172171M0201, rev. B 2012-01-18 15 www.abb.com/lowvoltage 8 EC Declaration of conformity EC Declaration of conformity (according to 2006/42/EC, Annex2A) We ABB AB JOKAB SAFETY Varlabergsgatan 11 SE-434 39 Kungsbacka Sweden declare that the safety components of ABB AB make with type designations and safety functions as listed below, is in conformity with the Directives 2006/42/EC 2006/95/EC Person authorised to compile the technical file Lars-Magnus Felth ABB AB JOKAB Safety Varlabergsgatan 11 SE-434 39 Kungsbacka Sweden Product Certificate Emergency stop device Smile, versions 10EA, 10EAK, 11EA, 12EA, 11EAR 1 1 - S K M - CM - 0 1 0 3 Em ergenc y s top dev ice I NC A 1 1 1 -S K M -C M-0 1 0 3 Emergency stop wire Stop Line Emergency stop wire JSNY10 N ot if ied Body In spec t a S weden AB Box 30100 SE-104 25 Stockholm Sweden Notified Body No. 0409 Used harmonized standards EN ISO 12100:2010, EN 954-1:1996, EN ISO 13849-1:2008/AC:2009, EN 60204-1:2007+A1, EN ISO 13850:2008 Mats Linger PRU Manager Kungsbacka 2011-03-04 www.abb.com www.jokabsafety.com Original ABB AB / JOKAB SAFETY Varlabergsvagen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage 2TLC172171M0201, rev. B 2012-01-18 16 www.abb.com/lowvoltage