DATASHEET
IR95-21C/TR9
6
Copyright © 2015, Everlight All Rights Reserved. Release Date :2016/11/28. Issue No:DIR-0001677 Rev.3
www.everlight.com
Precautions For Use
1. Over-current-proof
Customer must apply resistors for protection , otherwise slight voltage shift will cause big
current change( Burn out will happen ).
2. Storage
2.1 Do not open moisture proof bag before the products are ready to use.
2.2 Before opening the package, the LEDs should be kept at 10℃~30℃ and 90%RH or less.
2.3 The LEDs suggested be used within one year.
2.4 After opening the package, the devices must be stored at 10°C~30°C and ≤ 60%RH, and used
within 168 hours (floor life). If unused LEDs remain, it should be stored in moisture proof
packages.
2.5 If the moisture absorbent material (desiccant material) has faded or unopened bag has
exceeded the shelf life or devices (out of bag) have exceeded the floor life, baking treatment is
required.
2.6 If baking is required, refer to IPC/JEDEC J-STD-033 for bake procedure or recommend the
following conditions:
96 hours at 60°C ± 5°C and < 5 % RH (reeled/tubed/loose units)
3. Soldering Condition
3.1 Pb-free solder temperature profile
3.2 Reflow soldering should not be done more than three times.
3.3 When soldering, do not put stress on the LEDs during heating.
3.4 After soldering, do not warp the circuit board.