HITANO ENTERPRISE CORP. BY396 THRU BY399 TECHNICAL SPECIFICATIONS OF FAST RECOVERY RECTIFIER VOLTAGE RANGE - 100 to 800 Volts CURRENT - 3.0 Amperes FEATURES * Fast switching * Low leakage * Low forward voltage drop * High current capability * High current surge * High reliability DO-27 MECHANICAL DATA * Case: Molded plastic * Epoxy: UL 94V-0 rate flame retardant * Lead: MIL-STD-202E, Method 208 guaranteed * Mounting position: Any * Weight: 1.18 grams MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 oC ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) VRRM BY396 100 BY397 200 BY398 400 BY399 800 UNITS Maximum Recurrent Peak Reverse Voltage SYMBOL Maximum RMS Voltage VRMS 70 140 280 560 Volts VDC 100 200 400 800 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TA= 75o C Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC Method) Maximum Instantaneous Forward Voltage at 3.0A DC Maximum DC Reverse Current at Rated DC Blocking Voltage T A = 25 oC Maximum Full Load Reverse Current Average, o Full Cycle .375*(9.5mm) lead length at T L = 55 C IO 3.0 Amps IFSM 200 Amps VF 1.3 Volts 10 uAmps 150 uAmps IR Maximum Reverse Recovery Time (Note 1) trr Typical Junction Capacitance (Note 2) CJ 65 TJ, TSTG -65 to + 150 Operating and Storage Temperature Range NOTES : 1. Test Conditions: IF = 0.5A, IR = 1.0A, IRR = 0.25A 2. Measured at 1 MHZ and applied reverse voltage of 4.0 volts Volts 150 500 nSec pF 0 C RATING AND CHARACTERISTIC CURVES ( BY396 THRU BY399 )