CSM_1ZAP2_1VAP2_DS_E_3_1
1
Door Switches
1ZAP2/1VAP2
Door Switches with Built-in Basic
Switches for Long Life
Installation in electrical facilities, equipment doors, and other
openings helps ensure safety by reliably preventing accidents.
A Basic Switch if built in to provide a large switching capacity
and long service life.
Be sure to read Safety Precautions on page 3 and
Safety Precautions for All Basic Switches.
Ordering Information
Contact Form
Specifications
Note: 1. The 1VAP2-6 is also available with SPDT contacts. The model number
is 1VAP2-6 (V-15-1B6).
2. The built-in switch cannot be replaced.
Operation
Built-in Switch Model
Push
operation
Pull
operation
Self-reset Hold
Z-15GL42-B 1ZAP2
V-15-1B6 1VAP2-1
1VAP2-2
V-15-3B6 1VAP2-6
Model Name Contact form
1ZAP2
Double-throw
(SPDT)
1VAP2-1
1VAP2-2
1VAP2-6 Single-throw
(SPST-NO)
COM
NC
NO
COM NO
Item Model 1ZAP2 1VAP2-@
Built-in Switch Z-15GL42-B V-15-1B6/V-15-3B6
Rating
15 A, 125 VAC
(resistive load)
15 A, 250 V
(resistive load)
15 A, 125 VAC
(resistive load)
15 A, 250 V
(resistive load)
Ambient operating
temperature 25 to 80°C (with no icing or condensation)
Ambient operating
humidity 35% to 85%RH
Durability
Mechanical
100,000 operations min. 100,000 operations min.
Electrical 100,000 operations min. 25,000 operations min.
Degree of protection IP00
Electric shock
protection class Class II
PTI
(proof tracking index) 175
Pollution degree 3 (IEC 947-5-1)
2
1ZAP2/1VAP2
Dimensions (Unit: mm)
沈み位置最大3.2
動作位置最小6.35
自由位置最大11.1
6.4
11.1
11.1±0.13
5.5±0.4
110.7±0.4
Four, M4 × 0.7
#832UNC, Depth: 10
(unified screw thread)
19.5
Separator
5 6.4 dia. max.
78.6
6.35 dia.
34.9
7.1
25.4 ±0.13
16.7±0.4 57.2
Z-15GL42-B
Three, M4x5.5 binding machine screws
Internal toothed washer
7.9
FP
1ZAP2 Operating
Characteristics Model 1ZAP2
Operating force
Pretravel
Overtravel
OF max.
PT max.
OT min.
21.6 N
4.7 mm
3.2 mm
Free position FP max. 11.1 mm
Two, M3.5 holes
Two, M3.5
6.35 dia. 7.4 dia. max.
4.8 dia.
V-15-1B6 Basic Switch
Separator
Three, #4-40 UNC
round machine screws
13.2 40.6
(39.8)
33
±0.4
10.3
±0.3
6.4
12.7
±0.2
6.8
6.7
±0.3
20.6
±0.15
31
±0.2
4.9
46.9
±0.3
5.5
±0.2
FP
4.6
±0.3
1VAP2-1
1VAP2-1
OF max.
PT max.
OT min.
17.6 N
4.4 mm
2 mm
FP max. 9.5 mm
46.9±0.3
31±0.2
12.7
FP
4.9
4.8 dia.
7.4 dia. max.6.35 dia.
7.9 40.6
Two, M 3
Three, #4-40 UNC
round machine screws
V-15-1B6 Basic Switch
Separator
38.1±0.2
46
19.1±0.2
8.7±0.3
4.1 Three, M3 holes
6.4
12.7
1VAP2-2
1VAP2-2
OF max.
PT max.
OT min.
17.6 N
4.4 mm
2 mm
FP max. 9.5 mm
Mounting hole
FP
6.35 dia.
15
12 dia.
455866
4.2±0.2
P = 1 criss-cross
knurling
Stainless steel operation rod
V-15-3B6
Basic Switch
1
15.2
75.4
12
37
11
Cover (steel)
2
1.2
5
10
20
Two, 9-dia. lead wire
pullout holes
8
8
1VAP2-6
1VAP2-6
OF max.
PT max.
OT min.
14.7 N
6 mm
3 mm
FP max. 21 mm
Note: 1. The standard 1VAP2-6 has SPST-NO contacts.
2.
The 1VAP2-6 is also available with SPDT contacts. If SPDT contacts are required, order using the following model number. (The built-in switch is the V-15-1B6.)
1VAP2-6 (V-15-1B6)
3
1ZAP2/1VAP2
Safety Precautions
Refer to Safety Precautions for All Basic Switches.
Mounting Holes
Wiring
Tighten the terminal screws to the torque given in the following table.
Operating Environment
The Switch does not have a water-resistant structure. Take
measures to protect the Switch if it is to be used in locations subject
to splashing or spraying water or other liquids.
Do not use the Switch where it is continuously subjected to vibration
or shock. Doing so will result in contact failure, malfunction, or a
decrease in service life caused by abrasive powder that is
generated from the internal parts. Subjecting the Switch to
excessive vibration or shock may cause the contacts to
malfunction, stick, or become damaged. Make sure to install the
Switch in locations free of vibration or shock or in a direction where
resonance will not occur.
Do not use the Switch in locations subject to corrosive gas, such as
sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),
or chlorine gas (Cl2), or high temperature and humidity.
Doing so will result in damage due to contact failure or corrosion.
If the Switch is used in locations with silicone gas, arc energy may
cause silicon dioxide (SiO2) to build up on the contacts and contact
failure may result. If there is silicone oil, silicone sealant, or wire
covered with silicone close to the Switch, attach a contact
protective circuit to suppress the arcing of the Switch or eliminate
the source of silicone gas.
Use the switch within the specified range for operating temperature
and humidity. Using the Switch in high temperatures will cause the
operating characteristics to deviate. Rapid changes in temperature
will also cause the operating characteristics to deviate. It is
recommended to install the Switch as far as possible from heat
sources so that the temperature of the Switch is not affected.
Precautions for Correct Use
Mounting
direction 1ZAP2 1VAP2-1 1VAP2-2 1VAP2-6
Front mounting
Side mounting (Side mounting is not possible)
25.4±0.3
Two, 4.5 dia. holes
+0.3
0
20.6 ±0.3
Two, 4 dia. holes
+0.3
0
38.1±0.3
Two, 3.5 dia. holes
+0.3
0
58±0.3
37±0.3
0.3
0
Four, M4 or 4.5 dia. holes
11.1±0.3
11.1±0.3
10 dia. min.
Two, 4.5 dia. holes
+0.3
0
10.3±0.3
12.7±0.3
10 dia. min.
Two, 4 dia. holes
+0.3
0
±0.3
8.7
38.1±0.3
19.1±0.3
Two, 3.5 dia. holes
+0.3
0
10 dia. min.
1ZAP2 1VAP2
0.78 to 1.78 N·m 0.19 to 0.29 N·m
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2009.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2009 All Right Reserved.