ISSUE 5 50044171 GENERAL INFORMATION TruStability(R) High Accuracy Silicon Ceramic (HSC) Series and Standard Accuracy Silicon Ceramic (SSC) Series are piezoresistive silicon pressure sensors offering a digital output for reading pressure over the specified full scale pressure span and temperature range. They are available in standard pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) and are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases. The liquid media option extends the performance of these sensors to con-corrosive, non-ionic liquids. SOLDERING See soldering times and temperatures in Table 2. CLEANING CAUTION IMPROPER CLEANING Ensure cleaning fluids, such as appropriate alcohols or fluorinated solvents, are used based on the type of contaminants to be removed. Do not immerse the sensor. Failure to comply with these instructions may result in product damage. LIQUID MEDIA OPTION CAUTION Table 1. Environmental Specifications PRODUCT DAMAGE Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids. Ensure liquid media contains no particulates. All (R) TruStability sensors are dead-ended devices. Particulates can accumulate inside the sensor, causing damage or affecting sensor output. Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to enter and settle within the pressure sensor if it is in this position. Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a dead-ended sensor is difficult and has limited effectiveness for removing residue. Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and may lead to sensor failure. Failure to comply with these instructions may result in product damage. Table 2. Absolute Maximum Ratings Vibration Shock 1 Life Solder reflow Characteristic 0% to 95% RH, non-condensing 100% condensing or direct liquid media on Port 1 MIL-STD-202F, Curve AK (20.7 g random) MIL-STD-202F, Method 213B, Condition F 1 million cycles minimum J-STD-020-C 2 Parameter Supply voltage Voltage on output pin ESD susceptibility (human body model) Storage temperature range Soldering times and temperature: Lead solder (SIP, DIP) Peak reflow (SMT) Sensing and Control Parameter Humidity: Dry gases only Liquid media option Min. -0.3 -0.3 3 -40 [-40] Max. 6.0 Vsupply + 0.3 85 [185] 4 s max. at 250 C [482 F] 15 s max. at 250 C [482 F] Unit V V kV C [F] Table 3. Operating Specifications Parameter 3 Supply voltage (Vsupply) : 3.3 Vdc 5.0 Vdc Supply current: 3.3 Vdc supply 5.0 Vdc supply 5 Compensated temperature range : HSC Series SSC Series 6 Operating temperature range : HSC Series SSC Series 7 Accuracy Response time Resolution 8 Total error band : HSC Series SSC Series Bus standards Table 4. Wetted Materials Parameter Covers Substrate Adhesives Electronic components Min. Typ. Max. Unit 3.0 4.75 3.3 4 5.0 4 3.6 5.25 Vdc - 1.6 2 2.1 3 mA 0 [32] -20 [-4] - 50 [122] 85 [185] C [F] -20 [-4] -40 [-40] 12 0.46 - 85 [185] 85 [185] 0.25 - C [F] - %FSS BFSL ms bits 1 %FSS 2 2 I C, fast mode (400 kHz) Serial Peripheral Interface (SPI) 9 10 Port 1 (Pressure Port) high temperature polyamide alumina ceramic epoxy, silicone ceramic, glass, solder, silicon Port 2 (Reference Port) high temperature polyamide alumina ceramic epoxy, silicone silicon, glass, gold, solder Notes: 1. Life may vary depending on specific application in which the sensor is utilized. 2. Absolute maximum ratings are the extreme limits the device will withstand without damage. 3. Ratiometricity of the sensor (the ability of the digital device to maintain performance parameters independent of supply voltage) is achieved within the specified operating voltage for each option. Other custom supply voltages are available, please contact Honeywell Customer Service. 4. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 5. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within the specified performance limits. 6. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the specified performance limits. 7. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 C [77 F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 8. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. 9. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. (See figure 1 for ranges). 10. Contact Honeywell Customer Service for detailed material information. Table 5. Pinouts for SMT and DIP Packages Output Type 2 IC SPI Pin 1 GND GND Pin 2 Vsupply Vsupply Pin 3 SDA MISO Pin 4 SCL SCLK Pin 5 NC SS Pin 6 NC NC Pin 7 NC NC Pin 8 NC NC Table 6. Pinouts for SIP Package Output Type 2 IC 2 Honeywell Pin 1 GND Sensing and Control Pin 2 Vsupply Pin 3 SDA Pin 4 SCL 50044171 Issue 5 Figure 1. DIP Pressure Port Dimensional Drawings (For reference only: mm [in]) DIP NN: No ports DIP AN: Single axial barbed port 8 7 6 0,25 [0.010] 5,44 [0.214] 5 PORT 1 8 13,35 [0.525] 6,99 [0.275] PORT 2 13,75 [0.541] 10,0 [0.39] 7 6 5 0,25 [0.010] 7,95 [0.313] 10,0 [0.39] 6,2 [0.24] 13,35 [0.525] 6,99 PORT 2 [0.275] 4,93 DIA. [0.194] PORT 1 1 1 2 3 4 2 4 9,24 [0.364] 11,21 [0.441] 2,54 TYP. [0.100] 9,24 [0.364] 10,85 [0.427] 2,54 TYP. [0.100] 3 8X 0,46 [0.018] 8X 0,46 [0.018] DIP LN: Single axial barbless port 5,80 [0.228] 8 7 6 DIP RN: Single radial barbed port 0,25 [0.010] 5 8 7 6 5 2,47 DIA. [0.097] PORT 2 13,35 [0.525] 6,99 [0.275] 2 3 10,0 [0.39] 4,2 [0.17] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 PORT 1 1 0,25 [0.010] 5,80 [0.228] 10,0 [0.39] 1,93 DIA. [0.076] 4 9,24 [0.364] 2,54 TYP. [0.100] 1 11,21 [0.441] 3 4 9,24 [0.364] 11,21 [0.441] 2,54 TYP. [0.100] 13,75 [0.541] 6,95 [0.274] 2 1,00 [0.039] 8X 0,46 [0.018] 8X 0,46 [0.018] DIP RR: Dual radial barbed ports, same side 4,0 [0.16] 8 7 6 5 PORT 1 PORT 1 PORT 2 ,25 [0.010] 6,16 [0.242] 13,35 [0.525] 6,99 PORT 2 [0.275] DIP DR: Dual radial barbed ports, opposite sides 15,76 [0.620] 10,0 [0.39] 2X 1,93 DIA. [0.076] 2 3 4 2,54 TYP. [0.100] 7 6 5 2X 1,93 DIA. [0.076] 6,99 PORT 2 [0.275] PORT 1 4,65 [0.183] 1 8 0,25 [0.010] 6,16 [0.242] 10,0 [0.39] 13,35 [0.525] PORT 1 PORT 2 9,24 [0.364] 11,21 [0.441] 1 2 3 9,24 [0.364] 4 2,54 TYP. [0.100] 3,78 [0.149] 11,21 [0.441] 3,78 [0.149] 8X 0,46 [0.018] 8X 0,46 [0.018] Recommended PCB Pad Layout 0,813 DIA. [0.032] 13,08 [0.515] 2,54 [0.100] Honeywell Sensing and Control 3 Figure 2. SMT Pressure Port Dimensional Drawings (For reference only: mm [in]) SMT NN: No ports SMT AN: Single axial barbed port 8 7 6 13,75 [0.541] 10,0 [0.39] 5,44 [0.214] 5 8 6 5 10,0 [0.39] 7,95 [0.313] 13,4 [0.53] 6,99 PORT 2 [0.275] PORT 1 7 4,93 DIA. [0.194] PORT 2 13,4 [0.53] 6,99 [0.275] PORT 1 1 2 3 4 8X 0,46 [0.018] 4,80 [0.189] 6,41 [0.252] 2,54 TYP. [0.100] 1 5,80 [0.228] 7 6 4 4,80 [0.189] 6,77 [0.266] 8X 0,46 [0.018] SMT RN: Single radial barbed port 10,0 [0.394] 5 3 2,54 TYP. [0.100] SMT LN: Single axial barbless port 8 2 8 7 6 5,80 [0.228] 5 2,47 DIA. [0.097] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 10,0 [0.39] 4,2 [0.17] 13,3 [0.53] 6,99 PORT 2 [0.275] PORT 1 1,93 DIA. [0.076] PORT 1 1 2 3 1 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] 2 8X 0,46 [0.018] 3 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] 8X 0,46 [0.018] 13,75 [0.541] SMT RR: Dual radial barbed ports, same side 4,0 [0.16] 8 7 6 2X 1,93 DIA. [0.076] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 PORT 1 PORT 2 10,0 [0.39] 6,16 [0.242] 5 SMT DR: Dual radial barbed ports, opposite sides 2 3 4 2,54 TYP. [0.100] 4,80 [0.189] 6,77 [0.266] 15,8 [0.62] 8 8X 0,46 [0.018] 1 2 3 4 2,54 TYP. [0.100] 1,143 [0.045] 2,032 [0.080] 10,0 [0.39] 6,16 [0.242] 5 13,4 [0.53] 6,99 [0.275] PORT 2 Recommended PCB Pad Layout 9,40 [0.370] 2,54 [0.100] Sensing and Control 6 PORT 1 3,78 [0.149] 4 Honeywell 7 2X 1,93 DIA. [0.076] 4,6 [0.18] 1 2X 2,93 [0.115] 3,78 [0.149] 4,80 [0.189] 6,77 [0.266] 8X 0,46 [0.018] Issue 5 50044171 Figure 3. SIP Package Dimensional Drawings (For reference only: mm [in]) SIP NN: No ports SIP AA: Dual axial barbed ports, opposite sides 10,0 [0.39] 10,0 [0.39] 4,87 [0.192] 10,0 [0.39] PORT 1 22,06 [0.869] PORT 2 10,0 [0.39] PORT 2 PORT 1 2X 4.93 DIA. [0.194] 15,2 [0.60] 1 2 3 15,2 [0.60] 4 4X 0,51 [0.020] 1 0,25 [0.010] 2 3 2,54 TYP. [0.100] SIP AN: Single axial barbed port 10,0 [0.39] PORT 1 0,25 [0.010] 10,0 [0.39] 13,75 [0.541] 10,0 [0.39] PORT 2 2,47 DIA. [0.097] 15,2 [0.60] 15,2 [0.60] 2 3 4 4X 0,51 [0.020] PORT 2 PORT 1 4.93 DIA. [0.194] 1 2,54 TYP. [0.100] SIP LN: Single barbless port 13,75 [0.541] 10,0 [0.39] 4 4X 0,51 [0.020] 1 0,25 [0.010] 2,54 TYP. [0.100] 2 3 4 0,25 [0.010] 4X 0,51 [0.020] 2,54 TYP. [0.100] SIP FF: Fastener mount, dual axial barbed ports, opposite sides 27,20 [1.071] 29,48 [1.161] 23,12 [0.910] 10,44 [0.411] 17,78 [0.700] PORT 2 PORT 1 2X 3.94 DIA. [0.155] 2X 4,78 DIA. [0.188] 20,16 [0.794] 1 0,25 [0.010] 4X 0,51 [.020] 2 3 4 2,54 TYP. [0.100] SIP FN: Fastener mount, single axial barbed port 29,48 [1.161] 16,38 [0.645] 23,12 [0.910] 17,78 [0.700] PORT 2 2X 3.94 DIA. [0.155] PORT 1 4.78 DIA. [0.188] 20,16 [0.794] 1 4X 0,51 [0.020] 0,25 [0.010] 2 3 4 2,54 TYP. [0.100] Honeywell Sensing and Control 5 Figure 3. SIP Package Dimensional Drawings (continued) SIP GN: Ribbed fastener mount, single axial barbed port 27,96 [1.101] 21,60 [0.850] 16,51 [0.650] 19,06 [0.750] PORT 2 PORT 1 2X 3,94 DIA. [0.155] 4.78 DIA. [0.188] 10,63 [0.418] 1 0,25 [0.010] 4X 0,51 [0.020] 2 3 4 2,54 TYP. [0.100] SIP NB: Fastener mount, dual axial ports, same side 27,31 [1.075] 25,3 [0.996] 21,60 [0.850] 2X 4,80 DIA. [0.189] PORT 2 2X 3.50 DIA. [0.138] 22,87 [0.900] PORT 1 13 [0.52] 4 3 2 1 0,25 [0.010] 4X 0,51 [0.020] 2,54 TYP. [0.100] SIP RN: Single radial barbed port 10,0 [0.39] 5,80 [0.228] PORT 1 10,0 [0.39] PORT 2 1,92 DIA. [0.076] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 0,25 [0.010] 2,54 TYP. [0.100] SIP RR: Dual radial barbed ports, same side 10,0 [0.39] 6,16 [0.243] PORT 1 10,0 [0.39] PORT 2 2X 1,92 DIA. [0.076] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 6 Honeywell Sensing and Control 0,25 [0.010] 2,54 TYP. [0.100] Issue 5 50044171 Figure 3. SIP Package Dimensional Drawings (continued) SIP DR: Dual radial barbed ports, opposite side SIP HH: Fastener mount, dual radial barbed ports, same side 29,62 [1.166] 15,8 [0.62] 10,0 [0.39] 6,16 [0.243] 10,58 [0.416] 6,64 [0.261] 23,12 [0.910] PORT 2 10,0 [0.39] PORT 2 PORT 1 PORT 1 PORT 2 PORT 1 28,96 [1.140] 2X 4.93 DIA. [0.194] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 0,25 [0.010] 2,54 TYP. [0.100] 11,27 [0.444] SIP HN: Fastener mount, single radial barbed port 23,12 [0.910] 2 3 4 2,54 TYP. [0.100] SIP MN: Manifold mount, outer diameter seal 7,97 [0.314] 4,78 DIA. [0.188] 1 0,25 [0.010] 4X 0,51 [0.020] 5,36 [0.211] PORT 2 PORT 1 PORT 1 15,24 DIA. [0.600] 28,96 [1.140] PORT 2 12,5 [0.49] 2X 3,94 DIA. [0.155] 11,27 [0.444] 1 4X 0,51 [0.020] 0,25 [0.010] 4X 0,51 [0.020] 2 3 4 2,54 TYP. [0.100] 0,25 [0.010] 1 2 3 4 2,54 TYP. [0.100] SIP SN: Manifold mount, inner diameter seal PORT 2 12,57 [0.495] 5,1 [0.20] PORT 1 13,11 [0.516] 15,6 [0.61] 1 4X 0,51 [0.020] 2 3 4 2,54 TYP. [0.100] Recommended PCB Pad Layout 0,914 DIA. [0.036] 2,54 [0.100] Honeywell Sensing and Control 7 Issue 5 WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. 50044171 SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Internet: http://sensing.honeywell.com Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 http://sensing.honeywell.com 50044171-5-EN August 2012 Copyright (c) 2012 Honeywell International Inc. All rights reserved.