Power Sensor/Meter with USB Interface - Connect Directly to a PC ST series power sensors are complete miniature power meters. The sensors contain a CPU that controls the sensor, processes the measurement results and operates the interface. All measurement data and settings can be transmitted via a USB interface to and from a PC. This gives the concept of using a PC as the user interface in classic microwave power measurement. Satori Technology Limited 1 Biggar Business Park Market Road Biggar Lanarkshire ML12 6FX Thurlby Thandar Instruments Ltd. +44 (0) 1899-229258 Glebe Road, Huntingdon, Cambridgeshire (Office hours, GMT) Kingdom) PE29 7DR England (United Tel: +44 (0)1480 412451 sales@satori-technology.com Fax: +44 (0)1480 450409 support@satori-technology.com Email: info@tti-test.com www.satori-technology.com Web: www.tti-test.com Connecting a sensor directly to a PC is the most cost-effective method for high-precision power measurements, especially if a PC is used already for data acquisition and evaluation. This is commonly the case in production environments that include a process controller. Omitting the display unit saves space in the rack and reduces costs. The ST Series has the ability have multiple sensor heads connected to the PC and operated simultaneously. An added advantage to the production user Service technicians too will also appreciate this product since the power sensor is only 1.9 x 1.2 x 6.7 inches 34x 43 x 125mm and can easily be operated from a laptop. Satori currently plan to use the ST Series with a PDA as a controller to improve usability for the I&M Market. The Power Meter is controlled using the Satori software loaded on a PC. It can be used with windows XP operating system. This Software is powerful and flexible but easy to use. This is a virtual power meter with basic measurement functions for the PC workstation. A software toolkit is supplied to control the power sensors via the PC. This toolkit is supplied as standard with every ST sensor. It includes a DLL (dynamic link library) for individualized use of the entire sensor functionality with Windows and the user Interface. -1Revision: April 2008 ST Series Current Options and Ordering Information ST124SMA: 10MHz to 12.4GHz (Includes 6' USB sensor cable) Opt 001: removes sensor cable ST185SMA: 10MHz to 18.5GHz (Includes 6' USB sensor cable) Opt 001: removes sensor cable ST265SMA: 10MHz to 26.5GHz (Includes 6' USB sensor cable) Opt 001: removes sensor cable Accessories Provided ST 101 Getting Started Guide with Operating Manual ST 103 User Software on CD and Programming Manual Accessories Available ST 301 Type N (m) to sma (f) ST 302 Type N (m) to sma (m) ST 303 Type K(m) to sma(f) ST 304 Type N(m) to K(f) ST 305 Type N(m) to 2.4(f) ST 306 3dB attenuator sma(m) to sma(f) Satori Technology Limited 1 Biggar Business Park Market Road Biggar Lanarkshire Thurlby Thandar Instruments Ltd. ML12 6FX Glebe Road, Huntingdon, Cambridgeshire +44 (0) 1899-229258 PE29 7DR hours, England (United (Office GMT) Kingdom) Tel: +44 (0)1480 412451 sales@satori-technology.com Fax: +44 (0)1480 450409 support@satori-technology.com Email: info@tti-test.com www.satori-technology.com Web: www.tti-test.com ST 307 6dB attenuator sma(m) to sma(f) ST 308 10dB attenuator sma(m) to sma(f) ST 309 6' USB Sensor cable -2Revision: April 2008 ST Series Schottky Diode CW USB Power Sensor ST124SMA Frequency 10MHz to 12.4GHz Measurement range -50 to +20dBm CW Operating Temperature 0 to 50 deg C Shock 25G, 11 ms Vibration 15G, 100 to 2000Hz Linearity error 25 +/- 5 deg C +/-0.26 +/-0.46 +/-0.43 +/-1.46 Linearity variation 25 +/- 25 deg C +/-0.5 dB; 50MHz f 12.4GHz +/-0.7 dB; 10 MHz f < 50MHz Cal factor error 25 +/- 5 deg C +/-0.17 dB; 10 MHz < f < 12.4 GHz Cal factor variation 25 +/- 5 deg C 0.45 dB; f 50MHz 0.67dB; f < 50MHz Zero set +/-1.8 nW Noise 0.15 nW RMS Input SWR - max 1.2:1 Measurement Speed -50 to -35 dBm -35 to -20 dBm -20 to +20 dBm 8 measurements per sec 33 measurements per sec. 50 measurements per sec. dB; dB; dB; dB; -40dBm to +10dBm; 50MHz f 12.4GHz +10dBm to +20dBm; 50MHz f 12.4GHz -40dBm to +10dBm; f < 50 MHz +10dBm to +20dBm; f < 50 MHz Max input power (damage level) 200mW CW (+23dBm) Connector type SMA (m) Connectivity USB 2.0 (cable length up to 5m) USB power supply current Approx. 50mA Sensor Cable Length (std) 193cm Satori Technology Limited 1 Biggar Business Park Market Road Biggar Lanarkshire Thurlby Thandar Instruments Ltd. ML12 6FX Glebe Road, Huntingdon, Cambridgeshire +44 (0) 1899-229258 PE29 7DR hours, England (United (Office GMT) Kingdom) Tel: +44 (0)1480 412451 sales@satori-technology.com Fax: +44 (0)1480 450409 support@satori-technology.com Email: info@tti-test.com www.satori-technology.com Web: www.tti-test.com Dimensions (max) 34H x 43W x 125L (mm) Weight 83 grams Specifications include expanded uncertainty of measurement stated as the standard uncertainty of measurement multiplied by the coverage factor k=2 which corresponds to a coverage probability of approximately 95% for a normal distribution. Specifications subject to change - contact Satori Technology for latest information. -3Revision: April 2008 ST Series Schottky Diode CW USB Power Sensor ST185SMA Satori Technology Limited 1 Biggar Business Park Market Road Biggar Lanarkshire Thurlby Thandar Instruments Ltd. ML12 6FX Glebe Road, Huntingdon, Cambridgeshire +44 (0) 1899-229258 PE29 7DR hours, England (United (Office GMT) Kingdom) Tel: +44 (0)1480 412451 sales@satori-technology.com Fax: +44 (0)1480 450409 support@satori-technology.com Email: info@tti-test.com www.satori-technology.com Web: www.tti-test.com Frequency 10MHz to 18.5GHz Measurement range -50 to +20dBm CW Operating Temperature 0 to 50 deg C Shock 25G, 11 ms Vibration 15G, 100 to 2000Hz Linearity error 25 +/- 5 deg C +/-0.26 dB; +/-0.46 dB; +/-0.57 dB; GHz +/-0.44 dB; GHz +/-0.87 dB; +/-0.66 dB; 18.5GHz +/-0.43 dB; +/-1.46 dB; -40dBm to +10dBm; 50MHz f 12.4GHz +10dBm to +20dBm; 50MHz f 12.4GHz -40dBm to +10dBm; 12.4 GHz < f 15 +10dBm to +20dBm; 12.4 GHz < f 15 -40dBm to +10dBm; 15 GHz < f 18.5GHz +10dBm to +20dBm; 15 GHz < f -40dBm to +10dBm; f < 50 MHz +10dBm to +20dBm; f < 50 MHz Linearity variation 25 +/- 25 deg C +/-0.5 dB; 50MHz f 18.5GHz +/-0.7 dB; 10 MHz f < 50MHz Cal factor error 25 +/- 5 deg C +/-0.17 dB; 10 MHz < f < 18.5 GHz Cal factor variation 25 +/- 5 deg C 0.45 dB; f 50MHz 0.67dB; f < 50MHz Zero set +/-1.8 nW Noise 0.15 nW RMS Input SWR - max 1.2:1 Measurement Speed -50 to -35 dBm -35 to -20 dBm -20 to +20 dBm 8 measurements per sec 33 measurements per sec. 50 measurements per sec. Max input power (damage level) 200mW CW (+23dBm) Connector type SMA (m) Connectivity USB 2.0 (cable length up to 5m) USB power supply current Approx. 50mA Sensor Cable Length (std) 193cm Dimensions (max) 34H x 43W x 125L (mm) Weight 83 grams Specifications include expanded uncertainty of measurement stated as the standard uncertainty of measurement multiplied by the coverage factor k=2 which corresponds to a coverage probability of approximately 95% for a normal distribution. Specifications subject to change - contact Satori Technology for latest information. -4Revision: April 2008 ST Series Schottky Diode CW USB Power Sensor ST265SMA Frequency 10 MHz to 26.5 GHz Measurement range -50 to +20dBm CW Operating Temperature 0 to 50 deg C Shock 25G, 11 ms Vibration 15G, 100 to 2000Hz Linearity error /- 525 + deg C 0.27 dB; -35dBm to +20dBm; 10 MHz to 26.5 GHz Linearity variation 25 +/- 25 deg C 0.2 dB; 10 MHz to 6 GHz; -35dBm to +20dBm 0.25 dB; 6 GHz to 18.5 GHz; -35dBm to +20 dBm 0.46 dB; 18.5 GHz to 26.5 GHz; -35 dBm to +20 dBm Cal factor error 25 +/- 5 deg C 0.16 dB; 10 MHz to 6 GHz 0.19 dB; 6 GHz to 18.5 GHz 0.21 dB; 18.5GHz to 26.5 GHz Cal factor variation 25 +/- 5 deg C 0.2 dB; 10 MHz to 6 GHz 0.3 dB; 6 GHz to 18.5 GHz 0.35 dB; 18.5 GHz to 26.5 GHz Zero set 1.6 nW Noise 0.14nW standard deviation Input SWR - max 1.25:1 10 MHz to 18 GHz 1.35:1 18 GHz to 26.5GHz Measurement Speed -50 to -35 dBm -35 to -20 dBm -20 to +20 dBm Satori Technology Limited 1 Biggar Business Park Market Road Biggar Lanarkshire Thurlby Thandar Instruments Ltd. ML12 6FX Glebe Road, Huntingdon, Cambridgeshire +44 (0) 1899-229258 PE29 7DR hours, England (United (Office GMT) Kingdom) Tel: +44 (0)1480 412451 sales@satori-technology.com Fax: +44 (0)1480 450409 support@satori-technology.com Email: info@tti-test.com www.satori-technology.com Web: www.tti-test.com 8 measurements per sec 33 measurements per sec. 50 measurements per sec. Max input power (damage level) 200mW CW (+23dBm) Connector type K type* (m) Connectivity USB 2.0 (cable length up to 5m) USB power supply current Approx. 50mA Sensor Cable Length (std) 193cm Dimensions (max) 34H x 43W x 125L (mm) Weight 83 grams Specifications include expanded uncertainty of measurement stated as the standard uncertainty of measurement multiplied by the coverage factor k=2 which corresponds to a coverage probability of approximately 95% for a normal distribution. *K Connector is a registered trademark of the Anritsu Company. Specifications subject to change - contact Satori Technology Limited for latest information. -5Revision: April 2008