- 1 -
Revision: April 2008
Satori Technology Limited
1 Biggar Business Park
Market Road
Biggar
Lanarkshire
ML12 6FX
+44 (0) 1899-229258
(Office hours, GMT)
sales@satori-technology.com
support@satori-technology.com
www.satori-technology.com
Power Sensor/Meter with USB Interface –
Connect Directly to a PC
ST series power sensors are
complete miniature power
meters. The sensors contain a
CPU that controls the sensor,
processes the measurement
results and operates the
interface. All measurement data
and settings can be transmitted
via a USB interface to and from
a PC. This gives the concept of
using a PC as the user interface
in classic microwave power
measurement.
Connecting a sensor directly to a
PC is the most cost-effective
method for high-precision power
measurements, especially if a
PC is used already for data
acquisition and evaluation. This
is commonly the case in
production environments that
include a process controller.
Omitting the display unit saves
space in the rack and reduces
costs.
The ST Series has the ability
have multiple sensor heads
connected to the PC and
operated simultaneously. An
added advantage to the
production user Service
technicians too will also
appreciate this product since the
power sensor is only 1.9 x 1.2 x
6.7 inches 34x 43 x 125mm and
can easily be operated from a
laptop. Satori currently plan to
use the ST Series with a PDA as
a controller to improve usability
for the I&M Market.
The Power Meter is controlled
using the Satori software loaded
on a PC. It can be used with
windows XP operating system.
This Software is powerful and
flexible but easy to use. This is a
virtual power meter with basic
measurement functions for the
PC workstation.
A software toolkit is supplied to
control the power sensors via the
PC. This toolkit is supplied as
standard with every ST sensor. It
includes a DLL (dynamic link
library) for individualized use of
the entire sensor functionality
with Windows and the user
Interface.
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire
PE29 7DR England (United Kingdom)
Tel: +44 (0)1480 412451
Fax: +44 (0)1480 450409
Email: info@tti-test.com
Web: www.tti-test.com
ST Series Current Options and Ordering
Information
ST124SMA: 10MHz to 12.4GHz
(Includes 6’ USB sensor cable)
Opt 001: removes sensor cable
ST185SMA: 10MHz to 18.5GHz
(Includes 6’ USB sensor cable)
Opt 001: removes sensor cable
ST265SMA: 10MHz to 26.5GHz
(Includes 6’ USB sensor cable)
Opt 001: removes sensor cable
Accessories Provided
ST 101 Getting Started Guide with Operating Manual
ST 103 User Software on CD and Programming Manual
Accessories Available
ST 301 Type N (m) to sma (f)
ST 302 Type N (m) to sma (m)
ST 303 Type K(m) to sma(f)
ST 304 Type N(m) to K(f)
ST 305 Type N(m) to 2.4(f)
ST 306 3dB attenuator sma(m) to sma(f)
Satori Technology Limited
1 Biggar Business Park
Market Road
Biggar
Lanarkshire
ML12 6FX
+44 (0) 1899-229258
(Office hours, GMT)
sales@satori-technology.com
ST 307 6dB attenuator sma(m) to sma(f)
ST 308 10dB attenuator sma(m) to sma(f)
ST 309 6’ USB Sensor cable
- 2 -
Revision: April 2008
support@satori-technology.com
www.satori-technology.com
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire
PE29 7DR England (United Kingdom)
Tel: +44 (0)1480 412451
Fax: +44 (0)1480 450409
Email: info@tti-test.com
Web: www.tti-test.com
- 3 -
Revision: April 2008
Satori Technology Limited
1 Biggar Business Park
Market Road
Biggar
Lanarkshire
ML12 6FX
+44 (0) 1899-229258
(Office hours, GMT)
sales@satori-technology.com
support@satori-technology.com
www.satori-technology.com
ST Series Schottky Diode CW USB Power
Sensor ST124SMA
Frequency 10MHz to 12.4GHz
Measurement range -50 to +20dBm CW
Operating Temperature 0 to 50 deg C
Shock 25G, 11 ms
Vibration 15G, 100 to 2000Hz
Linearity error
25 +/- 5 deg C
+/-0.26 dB; -40dBm to +10dBm; 50MHz f 12.4GHz
+/-0.46 dB; +10dBm to +20dBm; 50MHz f 12.4GHz
+/-0.43 dB; -40dBm to +10dBm; f < 50 MHz
+/-1.46 dB; +10dBm to +20dBm; f < 50 MHz
Linearity variation
25 +/- 25 deg C
+/-0.5 dB; 50MHz f 12.4GHz
+/-0.7 dB; 10 MHz f < 50MHz
Cal factor error
25 +/- 5 deg C
+/-0.17 dB; 10 MHz < f < 12.4 GHz
Cal factor variation
25 +/- 5 deg C
±0.45 dB; f 50MHz
±0.67dB; f < 50MHz
Zero set +/-1.8 nW
Noise 0.15 nW RMS
Input SWR - max 1.2:1
Measurement Speed
-50 to -35 dBm
-35 to -20 dBm
-20 to +20 dBm
8 measurements per sec
33 measurements per sec.
50 measurements per sec.
Max input power
(damage level)
200mW CW (+23dBm)
Connector type SMA (m)
Connectivity USB 2.0 (cable length up to 5m)
USB power supply current Approx. 50mA
Sensor Cable Length (std) 193cm
Dimensions (max) 34H x 43W x 125L (mm)
Weight 83 grams
Specifications include expanded uncertainty of measurement stated as the standard
uncertainty of measurement multiplied by the coverage factor k=2 which corresponds to a
coverage probability of approximately 95% for a normal distribution.
Specifications subject to change – contact Satori Technology for latest information.
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire
PE29 7DR England (United Kingdom)
Tel: +44 (0)1480 412451
Fax: +44 (0)1480 450409
Email: info@tti-test.com
Web: www.tti-test.com
- 4 -
Revision: April 2008
Satori Technology Limited
1 Biggar Business Park
Market Road
Biggar
Lanarkshire
ML12 6FX
+44 (0) 1899-229258
(Office hours, GMT)
sales@satori-technology.com
support@satori-technology.com
www.satori-technology.com
ST Series Schottky Diode CW USB Power
Sensor ST185SMA
Frequency 10MHz to 18.5GHz
Measurement range -50 to +20dBm CW
Operating Temperature 0 to 50 deg C
Shock 25G, 11 ms
Vibration 15G, 100 to 2000Hz
Linearity error
25 +/- 5 deg C
+/-0.26 dB; -40dBm to +10dBm; 50MHz f 12.4GHz
+/-0.46 dB; +10dBm to +20dBm; 50MHz f 12.4GHz
+/-0.57 dB; -40dBm to +10dBm; 12.4 GHz < f 15
GHz
+/-0.44 dB; +10dBm to +20dBm; 12.4 GHz < f 15
GHz
+/-0.87 dB; -40dBm to +10dBm; 15 GHz < f 18.5GHz
+/-0.66 dB; +10dBm to +20dBm; 15 GHz < f
18.5GHz
+/-0.43 dB; -40dBm to +10dBm; f < 50 MHz
+/-1.46 dB; +10dBm to +20dBm; f < 50 MHz
Linearity variation
25 +/- 25 deg C
+/-0.5 dB; 50MHz f 18.5GHz
+/-0.7 dB; 10 MHz f < 50MHz
Cal factor error
25 +/- 5 deg C
+/-0.17 dB; 10 MHz < f < 18.5 GHz
Cal factor variation
25 +/- 5 deg C
±0.45 dB; f 50MHz
±0.67dB; f < 50MHz
Zero set +/-1.8 nW
Noise 0.15 nW RMS
Input SWR - max 1.2:1
Measurement Speed
-50 to -35 dBm
-35 to -20 dBm
-20 to +20 dBm
8 measurements per sec
33 measurements per sec.
50 measurements per sec.
Max input power
(damage level)
200mW CW (+23dBm)
Connector type SMA (m)
Connectivity USB 2.0 (cable length up to 5m)
USB power supply current Approx. 50mA
Sensor Cable Length (std) 193cm
Dimensions (max) 34H x 43W x 125L (mm)
Weight 83 grams
Specifications include expanded uncertainty of measurement stated as the standard
uncertainty of measurement multiplied by the coverage factor k=2 which corresponds to a
coverage probability of approximately 95% for a normal distribution.
Specifications subject to change – contact Satori Technology for latest information.
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire
PE29 7DR England (United Kingdom)
Tel: +44 (0)1480 412451
Fax: +44 (0)1480 450409
Email: info@tti-test.com
Web: www.tti-test.com
- 5 -
Revision: April 2008
Satori Technology Limited
1 Biggar Business Park
Market Road
Biggar
Lanarkshire
ML12 6FX
+44 (0) 1899-229258
(Office hours, GMT)
sales@satori-technology.com
support@satori-technology.com
www.satori-technology.com
ST Series Schottky Diode CW USB Power
Sensor ST265SMA
Frequency 10 MHz to 26.5 GHz
Measurement range -50 to +20dBm CW
Operating Temperature 0 to 50 deg C
Shock 25G, 11 ms
Vibration 15G, 100 to 2000Hz
Linearity error
/- 525 + deg C
±0.27 dB; -35dBm to +20dBm; 10 MHz to 26.5 GHz
Linearity variation
25 +/- 25 deg C
±0.2 dB; 10 MHz to 6 GHz; -35dBm to +20dBm
±0.25 dB; 6 GHz to 18.5 GHz; -35dBm to +20 dBm
±0.46 dB; 18.5 GHz to 26.5 GHz; -35 dBm to +20 dBm
Cal factor error
25 +/- 5 deg C
±0.16 dB; 10 MHz to 6 GHz
±0.19 dB; 6 GHz to 18.5 GHz
±0.21 dB; 18.5GHz to 26.5 GHz
Cal factor variation
25 +/- 5 deg C
±0.2 dB; 10 MHz to 6 GHz
±0.3 dB; 6 GHz to 18.5 GHz
±0.35 dB; 18.5 GHz to 26.5 GHz
Zero set ±1.6 nW
Noise 0.14nW standard deviation
Input SWR - max 1.25:1 10 MHz to 18 GHz
1.35:1 18 GHz to 26.5GHz
Measurement Speed
-50 to -35 dBm
-35 to -20 dBm
-20 to +20 dBm
8 measurements per sec
33 measurements per sec.
50 measurements per sec.
Max input power
(damage level)
200mW CW (+23dBm)
Connector type K type* (m)
Connectivity USB 2.0 (cable length up to 5m)
USB power supply current Approx. 50mA
Sensor Cable Length (std) 193cm
Dimensions (max) 34H x 43W x 125L (mm)
Weight 83 grams
Specifications include expanded uncertainty of measurement stated as the standard uncertainty of
measurement multiplied by the coverage factor k=2 which corresponds to a coverage probability of
approximately 95% for a normal distribution.
*K Connector is a registered trademark of the Anritsu Company.
Specifications subject to change – contact Satori Technology Limited for latest
information.
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire
PE29 7DR England (United Kingdom)
Tel: +44 (0)1480 412451
Fax: +44 (0)1480 450409
Email: info@tti-test.com
Web: www.tti-test.com