1© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6009_S02 • 2/5/2016
Not for new design after March 31, 2016
One world. One KEMET
Benets
16 – 48.6 V rated voltage
Individually balanced cells
IP–65 rated, (IP–67 optional)
Threaded, protected terminals
• Operatingtemperaturerangeof-40˚Cto+65˚C
Optional state of charge indicator
Cycle life > 500,000 cycles
RoHS Compliant
Made in USA
Overview
KEMET S02 Series Supercapacitors are bank modules with cells
in extruded metal holder.
Applications
Renewable energy systems
Starting systems
Automotive subsystems
Backup power/UPS
Ride through/power conditioning
Hybrid drive systems
Bank Module Supercapacitors
S02 Series, Modules with Cells in Extruded Metal Holder
Part Number System
S02 A T 5006 R016 AU808
Series
Conguration
Code Balancing
CongurationCode
Capacitor Type
Capacitance Code
(µF)
Capacitance
Tolerance
Rated Voltage
(VDC) Termination Code C-Spec
Supercapacitor,
Bank Modules
with cells in
extruded metal
holder
A = Analog with
clamping
T =Array, 2
dimensions
D = Array, 3
dimensions
First three digits
representsignicant
gures.Fourthdigit
speciesnumberof
zeros.
R = -0% 016 = 16 V
048 = 48 V
A=Therstmechanical
congurationofa
particular part number
B = Refers only
to part number
S02AT1656R048BU808
Blank = No monitor
U808 = Digital
Overvoltage
and analog over
temperature
monitor
2© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6009_S02 • 2/5/2016
Not for new design after March 31, 2016
Bank Module Supercapacitors – S02 Series, Modules with Cells in Extruded Metal Holder
Dimensions – Millimeters
S02AT5006R016AU808
S02AT1656R048AU808
Part Number
L
W
H
Nominal Tolerance Nominal Tolerance Nominal Tolerance
S02AT5006R016AU808 209 +/-1.0 136 +/-1.0 156 +/-1.0
S02AT1656R048AU808 194 +/-1.0 418 +/-1.0 156 +/-1.0
S02AT1656R048BU808 418 +/-1.0 194 +/-1.0 179 +/-1.0
S02AT1656R048BU808
3© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6009_S02 • 2/5/2016
Not for new design after March 31, 2016
Bank Module Supercapacitors – S02 Series, Modules with Cells in Extruded Metal Holder
Performance Characteristics
Item Performance Characteristics
Rated Voltage 16 – 48.6 V
Peak Voltage 17.1 – 15.1 V
Rated Voltage/Cell 2.7 V
Surge Voltage/Cell 2.85 V
Capacitance Range 165 F – 500 F
Capacitance Tolerance -0%(S02AT1656R048BU808-0%/+20)
Temperature Range -40°Cto+65°C
Storage Temperature Range -40°Cto+70°C
Life, DC
10 years, rated voltage, 25°C
ΔC<20%decrease,ESR<100%increase
Life, Endurance
1,000 hours, rated voltage, 65°C
ΔC<20%decrease,ESR<100%increase
Life, Shelf
2 years, no voltage, 70°C
ΔC<10%decrease,ESR<100%increase
Life, Cycle
1,000,000 cycles, rated to half rated voltage, 25°C
ΔC<20%decrease,ESR<100%increase
Standards Compliance RoHS
Approvals
Series/Part Number Test Type Test Standard
S02AT1656R048BU808
Vibration
SAE J2380 2014
ISO 16750-3 s4.1
(Table 12 & 14)
2014
Ingress Protection IP67 2014
Vibration and shock IEC 60068-2-6,27,29 pending Q1 2015
Temperature IEC 60068-2-14 pending Q1 2015
SAE Safety And Abuse SAE J2464 pending Q1 2015
Underwriters Laboratory UL810A pending Q1 2015
4© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6009_S02 • 2/5/2016
Not for new design after March 31, 2016
Bank Module Supercapacitors – S02 Series, Modules with Cells in Extruded Metal Holder
Environmental Compliance
All KEMET supercapacitors are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
Part Number S02AT5006R016AU8081S02AT1656R048AU8081S02AT1656R048BU8081
Parameter
Capacitance (F) 500 165 165
Capacitance Tolerance -0 -0 -0%/+20%
Rated Voltage (V) 16 48 48.6
Peak Voltage (V) 17.1 53.1 51.3
Impedance[AC1kHz](mΩ) 1.3 4.0 4.0
ESR,DC≤(mΩ)[10ms] 1.5 5.0 5.0
ESR[DC](mΩ)IEC(reference) 2.15 6.0 6.0
Overvoltage Monitor Yes Yes Yes
Peak Current 1s (A) 2300 2200 2200
Continuous Current (A)* 85 85 100
Short Circuit Current (A) 10,000 12,000 9,800
Balancing Method Active Active Active
Overvoltage & Over Temperature
Monitor
YES YES YES
Energy/Power
Maximum Stored Energy (Wh) 18.2 54.1 54.5
Energy Density (Wh/kg) 4.1 3.9 3.9
Energy Density (Wh/L) 3.6 4.4 3.8
Power Density (kW/kg) 9.9 10.5 8.5
Power Density (kW/L) 8.6 11.9 8.2
Maximum Power (kW/kg) 4.1 4.0 4.1
Physical
CongurationCode
AT
AD
AT
L x W x H (mm) 209 x 136 x 156 194 x 418 x 156 418 x 194 x 179
Weight (kg) 5.1 14 14.5
Volume (L) 4.4 12.4 14.5
*Rated current = continuous current with 20°C temperature rise.
1Preliminary (See Prototype Sample Disclaimer)
5© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6009_S02 • 2/5/2016
Not for new design after March 31, 2016
Bank Module Supercapacitors – S02 Series, Modules with Cells in Extruded Metal Holder
Mounting
Specicusersguidewithmountinginstructionsshipwithmodule.
Packaging Quantities
Part Number Capacitance
(F)
Rated
Voltage
Package
Type
Package
Quantity
Box
Weight
Box
Length
Box
Width
Box
Height
S02AT5006R016AU808 500 16 Box 1 13.0 lbs (5.9 Kgs) 11.0" (279 mm) 8.0" (203 mm) 10.5" (267 mm)
S02AT1656R048AU808 165 48 Box 1 33.0 lbs (15.0 Kgs) 18.25" (464 mm)
12.25" (311 mm)
11.0" (279 mm)
S02AT1656R048BU808 165 48.6 Box 1
Standard Marking
Model number
Serial number
• Date
Rated voltage
Capacitance value
Terminal markings
6© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6009_S02 • 2/5/2016
Not for new design after March 31, 2016
Bank Module Supercapacitors – S02 Series, Modules with Cells in Extruded Metal Holder
KEMET Corporation
World Headquarters
2835 KEMET Way
Simpsonville, SC 29681
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Corporate Of ces
Fort Lauderdale, FL
Tel: 954-766-2800
North America
Northeast
Wilmington, MA
Tel: 978-658-1663
Southeast
Lake Mary, FL
Tel: 407-855-8886
Central
Novi, MI
Tel: 248-994-1030
Irving, TX
Tel: 972-915-6041
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Europe
Southern Europe
Sasso Marconi, Italy
Tel: 39-051-939111
Skopje, Macedonia
Tel: 389-2-55-14-623
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Kamen, Germany
Tel: 49-2307-438110
Northern Europe
Wyboston, United Kingdom
Tel: 44-1480-273082
Espoo, Finland
Tel: 358-9-5406-5000
Asia
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Shenzhen, China
Tel: 86-755-2518-1306
Beijing, China
Tel: 86-10-5877-1075
Shanghai, China
Tel: 86-21-6447-0707
Seoul, South Korea
Tel: 82-2-6294-0550
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6701-8033
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
7© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6009_S02 • 2/5/2016
Not for new design after March 31, 2016
Bank Module Supercapacitors – S02 Series, Modules with Cells in Extruded Metal Holder
Disclaimer
All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are
not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use. The Information is intended for use only
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all productrelated warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
Prototype Sample Disclaimer
The Customer acknowledges the following limitations of the prototype samples:
(1) Prototype samples are manufactured from preliminary designs and manufacturing processes, may not represent nal designs, have not been released for
commercial use and are not subject to the same quality control procedures applicable to released products;
(2) Prototype samples are not qualied parts and are provided as-is by KEMET Electronics Corporation, which specically disclaims any and all warranties and
guarantees, explicit or implied, including without limitation the warranties of merchantability and tness for a particular purpose or use;
(3) Prototype samples are not intended for commercial use, are provided for engineering evaluation only and are not recommended for use in the Customer’s
production line; and
(4) The Customer assumes the risk of any and all uses that the Customer makes of the prototype samples.
Prototype Copyright Notice
COPYRIGHT KEMET ELECTRONICS CORPORATION 2013, all rights reserved
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Kemet:
S02AT5006T016AU809 S02AD1656T048AU809 S02AT5006R016AU808 S02AD1006R080A S02AD6605R080A
S02AD4005R080A