Analogue Signal Processing 156 Analogue Signal Processing The real world can be measured in many ways, for example, via temperature, humidity, air pressure and so forth. The parameters of these different physical qualities change continuously. Elements that monitor statuses and changes in statuses of a given environment, must reflect these continual changes. Within the framework of industrial monitoring tasks, the statuses of an environment are monitored by using sensors. These sensors should provide signals that enable connected evaluating and monitoring installations to draw detailed conclusions concerning the status of, for example, a production process. The sensor signals trace the continuous changes in the monitored range. The signals can be in analogue or digital form; which means in normal cases, an electrical voltage or current value is produced that corresponds proportionally to the monitored physical quantities. Increasing automation with the intention of achieving or maintaining certain predetermined statuses makes the processing of analogue values increasingly important. This is also true of fields beyond those where this has been necessary and standard for a long time, for example, processing technology in the chemical industry. Standard electrical signal values are the norm within the framework of this processing technology. Current values from 0...20 mA, 4...20 mA or voltage values from 0...10 V have been introduced as sensor output values for differing physical quantities. Weidmuller has taken account the need for increasing automation with the processing of these analogue signals, and offers a wide range of products that are designed for handling sensor signals. This means, units are made available for standard signals (0...20 mA, 4...20 mA, 0...10 V) that generate output signal values proportional to the variable input signals, and at the same time enable the safe separation of, for example, sensor circuits of an evaluation circuit. This safe separation is particularly important to avoid mutual interference of multiple sensor circuits, for example, ground loops in interlinked measurement circuits. The wide range of products includes all functions for converting separation and monitoring signals. The different designs in connection with the respective functions cover practically all applications in industrial measurement technology. With these new products, Weidmuller offers the possibility of taking into account the demands of modern automation technology with the inclusion of analogue signals. These products guarantee an elementary function between signals from the field and the further processing systems. The mechanical characteristics of these products correspond to those of the well-known Weidmuller products and are part of a continuous, ongoing concept. The signal conditioners can be combined together with other Weidmuller products. They have been electrically and mechanically designed to ensure that only a minimum of wiring and maintenance costs are necessary. The product program contains the following functions: Current transformer Voltage transformer Thermocouple conditioners for resistance thermometers Frequency signal conditioner Potentiometer conditioner AC signal conditioner Bridge measurement conditioner Limit value monitoring modules AD/DA converter These products are categorised according to functionality as pure signal conversion, 2-way-isolation, 3-way-isolation and as passive separation. Analogue Signal Processing The problem 157 Analogue Signal Processing 2-way-isolation separates the signals galvanically and decouples the measurement circuits. In so doing it eliminates potential differences caused by long cable lengths and common reference points. Furthermore, the galvanic isolation offers protection against destruction by overvoltage, and against inductive and capacitive interferences. 3-way-isolation also decouples the supply voltage from the input and output circuits, and enables the function with only one operating voltage. The passive isolator offers a further elementary advantage; it needs no additional voltage supply. The supply to the modules ensues via the input circuit and is the transferred to the output. This current loop supply is distinguished by very low power consumption. There are a large number of products available for measuring temperatures. RTD PT100 signals, in 2-, 3- and 4-wire technology, are converted to standardised 0 - 20 mA, 4 - 20 mA and 0 - 10 V signals. The modules which can be connected to commercially available thermocouples have cold junction compensation as standard. Furthermore, the modules amplify and linearize the voltage signals from the thermocouple. This guarantees an exact conditioning of analogue signals by eliminating sources of interference and errors. Frequency converters convert frequencies to standard analogue signals. This enables controllers connected in series to directly process impulse trains when making speed or rotational speed measurements. It is inconceivable to think about automation without analogue-digital-analogue converters. To bring together the aforementioned analogue form of describing the environment and the customary digital processing, within the framework of process monitoring, it is necessary to convert analogue signals into digital signals. Weidmuller offers modules for the following standard input and output signals: 0...20 mA, 4...20 mA and 0...10 V. 8-bit and 12-bit digital modules are available. All modules have an added input for making instantaneous measurements. Current monitoring modules enable the monitoring of current values up to 60 A in alternating or direct voltages. Over range or under range values trip the switching output. Modules with analogue outputs enable the continuous monitoring of currents via connected controls. Voltage monitoring modules can be used to monitor direct and alternating voltages. Voltage fluctuations, resulting from switching operations or network overloads, can be reliably recognised and reported via the adjustable threshold function. Modules for monitoring of revolutions and torque enable the control of cyclic movements on conveyor belts, ventilators and pumps. The output responds after a set amount of time, should the expected impulse not be received. The reliable potentialfree relay contact, signalises the interference to the responsible component group. 158 Design Overview Mini Coupler / Mini Conditioner DK Mini Coupler / MCZ Mini Conditioner Extensive range of electronic functions in terminal format Pluggable cross-connections with mini conditioners Mini couplers with screw-in cross-connection combs Mini couplers with screw connections Mini conditioners with tension clamp connections WAVESERIES WAVEANALOG / WAVEANALOG PRO / WAVECONTROL Pluggable PCB for fast service when the configuration is changed Pluggable cross-connection in base socket housing to distribute the power supply, marking (CC) in the block diagram on the head plate Pluggable connections with optional screw or tension clamp connection Analogue Signal Processing RS profiles Analog-/Digital-Converters Mounts onto TS 32 and TS 35 mounting rails Open, cost-saving design Variable housing width 159 Selection Table of Functions Function Areas of application DC signal conditioners Signal conditioning, signal isolation, suppression of mass loops Versions Page DC input/fixed functions and configurable inputs and outputs MCZ WAVEANALOG WAVEANALOG PRO 164 174-184 185 Motor current limitation, pressure alarm, direct disconnection of connected modules, safety function DC input/limit value monitoring DK MCZ 172 173 PT100 signal conditioners Temperature monitoring, noise rejection, electrical decoupling of visualization devices, suppression of mass loops, heating and cooling monitoring, overheating protection of motors RTD input/fixed functions and configurable inputs and outputs MCZ WAVEANALOG WAVEANALOG PRO 165 186-188 189 Thermocouple conditioners Temperature monitoring, noise rejection, electrical decoupling of visualization devices, suppression of mass loops, heating and cooling monitoring, overheating protection of motors Thermo input/fixed functions and configurable inputs and outputs WAVEANALOG WAVEANALOG PRO 190 191 Flow rate measurements, frequency converter monitoring, speed measurements, pulse processing Input/fixed functions and configurable inputs and outputs DK MCZ 167-168 166 AD/DA converters Conditioning of voltage and current signals in 8-bit/12-bit digital form 8-bit AD/DA converter 12-bit AD/DA converter RS 210-213 Current monitoring Motor current monitoring, emergency lighting monitoring AC input/measuring of sinusoidal and non sinusoidal signals up to 60A DKI WAVECONTROL SMSI 172 196-199 200-203 Voltage monitoring Under and overvoltage monitoring, operating status indication One and three-phase overvoltage SMSU 204-205 Motion and rotational speed monitoring Downtime monitoring, conveyor-drive monitoring, monitoring of fans, pumps or pistons PNP/NPN or NAMUR input/switching output DKLW SMS 169 206 Namur switching amplifier Switching amplifier Namur input/switching output EGV 207 Setpoint device Testing measuring distances, defined input of analogue values 1 control input/+/-set value/ analogue output EMA/SW24 208 Frequency signal conditioners 160 Description Selection Table DC/DC Input Output Galvanic isolation Voltage supply Setting Module Connection width/mm type Cat. No. Page 0...20mA 0...20mA yes Fixed 6 Tens. clamp 8411190000 164 0...20mA 0...20mA yes Without auxiliary pwr. current loop supply from input Without auxiliary pwr. current loop supply from input Without auxiliary pwr. current loop supply from input 19.2...28.8Vdc/ Voltage supply of both sides 18...30Vdc Fixed 17.5 Screw/ tens. clamp 8444950000/ 174 0...20mA 0...20mA 0...20mA 0...20mA 0...20mA 0...20mA 0...20mA 0...20mA 0...20mA 0...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 0...10V 0...10V 0...10V 0...10V 0...10V 0...10V 0...10V 0...20mA 0...20mA 0...20mA 0...20mA 4...20mA 4...20mA 4...20mA 0...10V 0...10V 0...10V 0...20mA 0...20mA 0...20mA 4...20mA 4...20mA 4...20mA 0...10V 0...10V 0...10V 0...20mA 0...20mA 0...20mA 4...20mA 4...20mA 4...20mA 0...10V yes 2-way yes 3-way 2-way yes 3-way 2-way yes 3-way 2-way yes 3-way 2-way yes 3-way 2-way yes 3-way 2-way yes 3-way 2-way yes 3-way 2-way 18...30Vdc 19.2...28.8Vdc/ Voltage supply of both sides 18...30Vdc 18...30Vdc 19.2...28.8Vdc/ Voltage supply of both sides 18...30Vdc 18...30Vdc 19.2...28.8Vdc/ Voltage supply of output side 18...30Vdc 18...30Vdc 19.2...28.8Vdc/ Voltage supply of output side 18...30Vdc 18...30Vdc 19.2...28.8Vdc/ Voltage supply of output side 18...30Vdc 18...30Vdc 19.2...28.8Vdc/ Voltage supply of both sides 18...30Vdc 18...30Vdc 19.2...28.8V/ Voltage supply of both sides 18...30Vdc 18...30Vdc 19.2...28.8Vdc/ Voltage supply of both sides 8444960000 (1-channel) Fixed 17.5 Screw/ tens. clamp 8463580000/ 174 8463590000 (2-channel) Fixed Fixed/10 Hz 12.5 17.5 Fixed/20 kHz 17.5 Fixed Fixed/10 Hz 12.5 17.5 Fixed/20 kHz 17.5 Fixed Fixed/10 Hz 12.5 17.5 Fixed/20 kHz 17.5 Fixed 12.5 Fixed/10 kHz 17.5 Fixed/20 kHz 17.5 Fixed Fixed/10 Hz 12.5 17.5 Fixed/20 kHz 17.5 Fixed Fixed/10 Hz 12.5 17.5 Fixed/20 kHz 17.5 Fixed Fixed/10 Hz 12.5 17.5 Fixed/20 kHz 17.5 Fixed Fixed/10 Hz 12.5 17.5 Fixed/20 kHz 17.5 Fixed 12.5 Screw/ tens. clamp 8445070000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540180000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540250000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540270000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540200000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540180000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540230000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540310000/ Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540290000/ 176 8445080000 178 8540190000 8447160000/ 181 8447170000 8446970000/ 176 8446990000 181 8540260000 8447190000/ 181 8447200000 8447020000/ 176 8447030000 178 8540280000 8447220000/ 181 8447230000 8444980000/ 175 8444990000 179 8540210000 8447250000/ 182 8447260000 8445010000/ 175 8445020000 178 8540190000 8447160000/ 182 8447170000 8445040000/ 175 8445050000 179 8540240000 8447280000/ 182 8447290000 8447050000/ 177 8447080000 180 8540320000 8447310000/ 183 8447320000 8447100000/ 177 8447110000 180 8540300000 8447340000/ 183 8447350000 8447130000/ 177 8447140000 161 Analogue Signal Processing Function Selection Table Function Input Output Galvanic isolation Voltage supply Setting Module Connection width/mm type Cat. No. Page 0...10V 0...10V yes 18...30Vdc Fixed/10 Hz 17.5 Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8540330000/ 180 Screw/ tens. clamp Screw/ tens. clamp Tens. clamp 8432210000/ 8425720000 165 Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp Screw/ tens. clamp 8432150000/ 187 Screw/ tens. clamp 8432300000/ Screw/ tens. clamp 8560720000/ 0...10V Variable voltage and current (+/-20mV...+/-200V, +/-0.1mA...+/-100mA) PT100/ RTD/DC Thermo/DC Frequency/DC Limit value monitoring PT100/ 2-wire PT100/ 2-wire PT100/ 3-wire PT100/ 3-wire PT100/0 4-wire PT100/ 4-wire PT100/ 2-/3-/4-conduct. Ni100 Potentiometer: min. 0...100 max. 0...100k R: 0...450 K, J, T, E, N, R, S, B Thermo K, J, T, E, N, R, S, B Thermocouples K, J, T, E, N, R, S, B 0...50/100/500Hz 0...1/5/10/16kHz 0...50/100/500Hz 0...1/5/10/16kHz 0...50/100/500Hz 0...1/5/10/16kHz 0...20mA 0...20mA 4...20mA Variable voltage yes and current (-10V...+10V, -20mA...+20mA) (4)...20mA no 0...10V no 4...20mA no 0(4)...20mA no 0...10V (4)...20mA 0...10V no no no 0...10V 0...20mA 4...20mA yes 0...10V 0...20mA 4...20mA 0...10V 0...20mA 4...20mA 0(4)...20mA no no 0(4)...20mA yes 18...30Vdc 20...253Vdc 19.2...28.8Vdc 19.2...28.8Vdc current loop supply in output 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 18...30Vdc 19.2...28.8Vdc 18...30Vdc Fixed/20 kHz 17.5 DIP switch 12.5 Potentiometer DIP switch DIP switch Potentiometer Fixed 12.5 12.5 6 DIP switch Potentiometer DIP switch Potentiometer DIP switch Potentiometer DIP switch Potentiometer DIP switch Potentiometer 12.5 DIP switch 12.5 12.5 12.5 12.5 17.5 8447370000/ 184 8447380000 8560740000/ 185 8560750000 186 8432220000 8432180000/ 186 8432190000 8432160000 8432090000/ 187 8432130000 8432270000/ 188 8432280000 8432240000/ 188 8432250000 8560700000/ 189 8560710000 190 8432310000 17.5 21.6...26.4Vdc DIP switch 6 Screw 8311870001 168 no 21.6...26.4Vdc DIP switch 6 Screw 8311870001 168 0...10V no 21.6...26.4Vdc DIP switch 6 Screw 8283810000 168 0...1/5/10/16kHz 0...1/5/10/16kHz 0...1/5/10/16kHz no no no DIP switch DIP switch DIP switch 6 6 6 Screw Tens. clamp Screw 8258870000 8081330000 167 166 167 4...20mA 0...1/5/10/16kHz no DIP switch 6 Tens. clamp 8461490000 166 0...10V 0...10V Variable, programmable 0...20mA 0...1/5/10/16kHz 0...1/5/10/16kHz Switching output PNP Switching output PNP 2-channel Switching output PNP 2-channel Switching output PNP 2-channel Switching output PNP 2-channel 8-bit 8-bit 8-bit 8-bit 12-bit 12-bit 12-bit 12-bit no no no 21.6...26.4Vdc 21.6...26.4Vdc current loop supply in input current loop supply in input 21.6...26.4Vdc 21.6...26.4Vdc 19.2...28.8Vdc DIP switch DIP switch Fixed 6 6 12 Screw Tens. clamp Screw 8242040000 no 19.2...28.8Vdc Potentiometer 6 Screw 8031320000 167 166 170171 172 no 19.2...28.8Vdc Potentiometer 6 Tens. clamp 8227350000 173 no 19.2...28.8Vdc 6 Screw 8019640000 172 no 19.2...28.8Vdc 6 Tens. clamp 8260280000 173 no no no no no no no no 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc DIP switch Potentiometer DIP switch Potentiometer Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed 70 70 70 70 70 70 70 70 Screw Screw Screw Screw Screw Screw Screw Screw 1160561001 210 210 210 210 212 212 212 212 0...10V 0...10V 0...20mA 4...20mA 0...10V 0...20mA 4...20mA 0...10V 162 3-way DIP switch Potentiometer 0...20mA AD convert. 0...10V 8540340000 191 8560730000 8461480000 8461470000 8248340000 1168561001 1160361001 1122361001 1168461001 1169161001 1168361001 1168261001 Selection Table DA convert. Current monitoring Voltage monitoring Input Output 8-bit 8-bit 8-bit 8-bit 12-bit 12-bit 12-bit 12-bit 0...1/5/10 Aac 0...1/5/10 Aac 0...20/40/60 Aac 0...20/40/60 Aac 0...1/5/10 Aac 0...1/5/10 Aac 0...1/5/10 Aac 0...1/5/10 Aac 0...5/10 Aac 0...5/10 Aac 0...20/25/30 Aac 0...20/25/30 Aac 0...20/40/60 Aac 0...20/40/60 Aac 0.1...2A 0...20mA 4...20mA 0...10V 1...50mAdc 40...250mAdc 40...250mAdc 0.2...2.2Aac 1...5Aac 1...5Aac 1...5Aac 40...250mAdc 40...250mAdc 0.2...2.2Aac 1...5Aac 1-24Vdc 1-230Vuc 18...24Vac 36...48Vac 83...110Vac 165...220Vac 200...260Vac 3 phase 165...230Vac 3 phase 165...230Vac P. / N. switching 24Vdc Rotationalmotion and r.p.m. monitoring Namur switch Namur amplifier Namur Setpoint device 0...24V 1) 2) 3) 4) 5) Galvanic isolation Voltage supply Setting Module Connection width/mm type Cat. No. Page 211 211 211 211 213 213 213 213 196 196 196 196 197 197 197 197 198 198 198 198 199 199 no no no no 0...20mA no 4...20mA no 0...10V no no 1) 2-way 1) 2-way 1) 2-way 1) 2-way 2) 2-way 2) 2-way 3) 2-way 3) 2-way 4) 2-way 4) 2-way 4) 2-way 4) 2-way 4) 2-way 4) 2-way Switching output no PNP Opto-coupler yes Opto-coupler yes Opto-coupler yes Opto-coupler yes 21.6...26.4Vuc yes 5...48Vdc yes LED yes NO 1-channel yes NO 1-channel yes NO 1-channel yes NO 1-channel yes CO 1-channel yes CO 1-channel yes CO 1-channel yes CO 1-channel yes CO 1-channel yes CO 1-channel yes NO 1-channel yes NO 2-channel yes NO/NC yes CO 1-channel no 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 19.2...28.8Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 12...30Vdc 12...30Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc 18...30Vdc Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed DIP sw./P* DIP sw./P* DIP sw./P* DIP sw./P* DIP switch DIP sw./P* DIP sw./P* DIP sw./P* DIP sw./P* DIP sw./P* DIP sw./P* DIP sw./P* DIP sw./P* DIP sw./P* Fixed 70 70 70 70 70 70 70 70 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 6 Screw Screw Screw Screw Screw Screw Screw Screw Screw Tens. clamp Screw Tens. clamp Screw Tens. clamp Screw Tens. clamp Screw Tens. clamp Screw Tens. clamp Screw Tens. clamp Screw 1165860000 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 10...250Vdc 21.6...26.4Vuc 207...253Vac 18...27Vac 36...53Vac 83...121Vac 165...253Vac 200...299Vac 165...230Vac 165...230Vac 195.5...241.5Vac Op. point Op. point Op. point Op. point Fixed Fixed Fixed Op. point Op. point Op. point Fixed Op. point Op. point Op. point Op. point Op. point Op. point Op. point Op. point Op. point Potentiometer 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw Screw 1157160000 NO 1-channel PNP/NPN 10.5...+10.5V 21.6...26.4Vdc 21.6...26.4Vdc 21.6...26.4Vdc no no Potentiometer 22.5 22.5 22.5 Screw Screw Screw 1120360000 no no yes Switch output / 1 changeover contact 0...10 V, 0 (4)...20 mA switchable 4...20 mA / current loop supply Switch output / 1 changeover contact 0...10 V, 0 (4)...20 mA switchable 1169260000 1160760000 1123360000 1166060000 1165960000 1166160000 1160860000 8516560000 8516570000 8513340000 8526600000 8523400000 8523410000 8528650000 8528660000 8526610000 8526620000 8545830000 8545840000 8513330000 8526590000 1156360000 1156460000 1157360000 1112160000 8026930000 1112060000 1156660000 1159960000 1156960000 1112260000 0555060000 0555160000 1156760000 1157660000 1157760000 1157860000 1160160000 1156560000 1178760000 1110560000 1122460000 1172660000 200 200 201 201 201 201 201 202 202 203 203 205 205 204 204 205 205 205 205 205 206 207 207 208 DIP switch./P* = DIP switch / Potentiometer 163 Analogue Signal Processing Function Passive Isolator MCZ CCC 0...20 mA/0...20 mA This module is a reasonably priced passive separator for galvanically separating standard 0.4...20 mA signals. It draws its power from the measurement signal and requires no further auxiliary power. The measurement signal is transmitted 1:1. The module is distinguished by its low power consumption as well as a response current <100 A. Block diagram Working resistance diagram UE (V) IE = IA = 20 mA 15 3 100 Ordering data for TS 35 500 RB () Type MCZ CCC 0...20 mA/0...20 mA without power supply Cat. No. 8411190000 Technical data Input 0...20 mA (max. 15 V) Response current Voltage drop Max. overload capacity at input < 100 A 2.5...3 V (at 20 mA) 50 mA, 15 V Output 0...20 mA (max. 10 V) Set time (T99) Residual ripple approx. 5 ms at 500 working resistance impedance < 10 mVeff Chopper frequency Transmission error Temperature effect approx. 200 kHz < 0.1 % from end value, + 0.05 % from mean/100 working resistance < 50 ppm/K from measurement value for working resistance 0 Voltage strength Input/output 510 Veff EMC Approvals EMVG EN 50081-1 EN 50082-2 CE, UL, CSA Ambient temperature - assembled without spacing - assembled with 20 mm spacing Storage temperature Conductor Conductor cross-section Overall width -25 C...+40 C -25 C...+50 C -40 C ...+85 C AWG 22...12 1.5 mm2 6 mm Dimensions and accessories see Page 305 164 RTD Thermocouple Conditioners * for 2 and 3 wire sensors MCZ PT100/3 CLP 0...100 C / 0...120 C / 0...150 C / 0...200 C / 0...300 C -50...+150 C / -40...100 C The temperature module converts measurement values from a PT 100 into analogue measurement signals. The module supplies the sensor with power. The module is distinguished by its accuracy and linearity. Block diagram Type MCZ PT100/3 MCZ PT100/3 MCZ PT100/3 MCZ PT100/3 MCZ PT100/3 MCZ PT100/3 MCZ PT100/3 CLP CLP CLP CLP CLP CLP CLP 0...100 C 0...120 C 0...150 C 0...200 C 0...300 C -50...+150 C -40...100 C Technical data Input Connection Max. wire resistance Leadwire resistance effect Supply current PT 100 (according to IEC 751) 3-wire / 2-wire* each 50 max. 0.006 C/ 0.8 mA Output Load Supply voltage Residual ripple of supply voltage Set time Accuracy Linearity Temperature coefficient 4...20 mA** 750 at 24 V max: 30V / min: 9 V+20mA x RL max: 1.5 V at 100 Hz 10 ms Type. 0.2 % max. 0.5 % v. FSR <0.1 % v. FSR max. 250 ppm/C Open circuit recognition yes EMC Approvals EMVG EN 50081-1 EN 50082-2 CE, UL, CSA Ambient temperature Storage temperature Conductor Conductor cross-section Overall width 0 C...+50 C -20 C...+85 C AWG 22...12 1.5 mm2 6 mm * Putting a bridge between Pins 4 and 5 ** current loop supplied Dimensions and accessories see Page 305 Cat. No. 8425720000 8483680000 8604420000 8473010000 8473020000 8473000000 8604430000 Analogue Signal Processing Ordering data for TS 35 165 Frequency Signal Conditioners * Tension clamp connection * LED-Display * Adjustable frequency output MCZ VFC MCZ CFC MCZ CFC 0...10 V 0...20 mA 4...20 mA CLP The option of reading-in the analogue signals from the field via counter inputs of the control is made possible by converting the analogue signals in to frequencies. It is recommended that twisted and shielded 2-wire cables are used. Block diagram/settings MCZ VFZ 0...10 V and MCZ CFC 0...20 mA 1 1 0 0 0 2 0 1 0 0 3 0 0 1 0 4 0 0 0 1 MCZ CFC 4...20 mA CLP 1 2 3 4 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 DIP switch 0...16 kHz 0...8 kHz 0...4 kHz 0...1 kHz DIP switch 3.2...16 kHz 1.6...8 kHz 0.8...4 kHz 0.2...1 kHz Ordering data for TS 35 Technical data Input ranges Type W MCZ VFC Cat. No. 8461470000 Type MCZ CFC Cat. No. 8461480000 Type MCZ CFC Cat. No. 8461490000 0...10 V 0...20 mA 4...20 mA LP* Overload limits, input Input resistance Voltage drop, input Output Output frequency, end value Frequency adjustment Readjustment range Output level Output current Display 30 V 100 k 50 mA 50 1 V at 20 mA 50 mA 1 kHz, 4 kHz, 8 kHz, 16 kHz DIL switch 10 %, internal PNP, Ub- 0.7 V max. 20 mA LED, pulsing 1 kHz, 4 kHz, 8 kHz, 16 kHz DIL switch 10 %, internal PNP, Ub- 0.7 V max. 20 mA LED, pulsing 1 kHz, 4 kHz, 8 kHz, 16 kHz DIL switch 10 %, internal PNP, Ub- 0.7 V max. 20 mA LED, pulsing Supply voltage Power consumption Making current limit Polarisation protection 24 Vdc 10 % 14 mA, w/o load 200 mA yes 24 Vdc 10 % 14 mA w/o load 200 mA yes 24 Vdc 20 % 14 mA w/o load Accuracy Temperature coefficient Coordination of insulation according to EN 50178 Voltage strength input/output Rated voltage Rated surge voltage Overvoltage category Voltage strength I/O to mounting rail Operating temperature Storage temperature Overall width Conductor cross-section 0.2 % v. FSR < 250 ppm/C 0.2 % v. FSR < 250 ppm/C 0.15 % v. FSR < 250 ppm/C 1 kVdc 100 V 1.5 kV III 4 kVeff/ 1 min 0 C...+50 C -25 C...+85 C 6 mm 1.5 mm2 1 kVdc 100 V 1.5 kV III 4 kVeff/ 1 min 0 C...+50 C -25 C...+85 C 6 mm 1.5 mm2 150 V 2.5 kV III 4 kVeff/ 1 min 0 C...+50 C -25 C...+85 C 6 mm 1.5 mm2 Dimensions and accessories see Page 305 Page 305 Page 305 5.8...6.4 at 20 mA yes * without DC/DC converter input supply vie current loop 166 Frequency Signal Conditioners DKA U/f * Screw connection * LED-Display * Adjustable frequency output DKA I/f DKA I/f* For EMC reasons, frequency processing modules must be used in conjunction with shielded cables. This measure prevents interference of analogue and frequency signals by other signal cables and vice versa. Block diagram/settings DKA U/f and DKA I/f 1 2 3 1 0 0 0 1 0 0 0 1 0 0 0 4 0 0 0 1 Ordering data for TS 32 for TS 35 with combi foot TS 32/TS 35 Technical data Input ranges DIP switch 0...16 kHz 0...8 kHz 0...4 kHz 0...1 kHz Type Cat. No. Type Cat. No. Type Cat. No. Y W DKA U/f 8242040000 DKA I/f 8258870000 DKA I/f * 8081330000 0...10 V 0...20 mA 4...20 mA Overload limits, input Input resistance Voltage drop, input Output Output frequency, end value Frequency adjustment Readjustment range Output level Output current Display Decoupling diode 100 V 100 k 50 mA 50 1 V at 20 mA 50 mA max. 320 at 20 mA max. 6.4 V at 20 mA 1 kHz, 4 kHz, 8 kHz, 16 kHz DIL switch 10 %, internal PNP, Ub- 0.7 V max. 20 mA LED, pulsing present 1 kHz, 4 kHz, 8 kHz, 16 kHz DIL switch 10 %, internal PNP, Ub- 0.8 V max. 20 mA LED, pulsing present 5 kHz (1...5 kHz) Supply voltage Power consumption Making current limit Polarisation protection 24 Vdc 10 % 14 mA, w/o load 200 mA yes 24 Vdc 10 % 14 mA w/o load 200 mA yes 19.2...28.8 Vdc <13 mA w/o load Accuracy 0.2 % v. FSR <250 ppm/C 0.2 % v. FSR <250 ppm/C 0.15 % v. FSR <250 ppm/C 2 1 kVdc 1 kVdc 4 kVeff 0 C...+50 C -25 C...+60 C 6 mm 0.5...4 mm2 4 kVeff 0 C...+50 C -25 C...+60 C 6 mm 0.5...4 mm2 4 kVeff 150 V 2.5 kV III 4 kVeff 0 C...+50 C -25 C...+60 C 6 mm 0.5...4 mm2 Accessories End plate Dimensions and accessories see Type AP DK5 Page 305 Cat. No. 8268870000 Type AP DK5 Page 305 present Analogue Signal Processing Coordination of insulation to DIN VDE 0160, Draft 11/94 Voltage strength input/output Rated voltage Rated surge voltage Overvoltage category Voltage strength to mounting rail Operating temperature Storage temperature Overall width Conductor cross-section Ub- 3 V max. 20 mA yes Cat. No. 8268870000 Type AP DK5 Page 305 Cat. No. 8268870000 * without DC/DC converter Input current loop supplied 167 Frequency Signal Conditioners * * * * DKA f/U Screw connection LED-Display Adjustable frequency output multiplex capable DKA f/I For EMC reasons, frequency processing modules must be used in conjunction with shielded cables. This measure prevents interference of analogue and frequency signals by other signal cables and vice versa. Block diagram/settings 1 0 1 0 1 0 1 1 0 X X 2 0 0 1 1 1 0 1 0 X X 3 0 0 0 0 1 1 1 1 X X 4 X X X X X X X X 0 1 Ordering data for TS 32 for TS 35 with combi foot TS 32/TS 35 Technical data Input ranges DIP switch 0...50 Hz 0...100 Hz 0...500 Hz 0...1 kHz 0...5 kHz 0...10 kHz 0...16 kHz Customer specific 0...20 mA / 0...10 V 4...20 mA / 2...10 V Type Cat. No. Type Cat. No. Y W DKA f/U 8283810001 DKA f/I 8311870001 0...50/100/500 Hz 0...1/5/10/16 kHz 0...50/100/500 Hz 0...1/5/10/16 kHz 10 k 10 k 0/2...10 V 0/4...20 mA DIL switch DIL switch Supply voltage Power consumption Making current limit Polarisation protection 24 Vdc 10 % 32 mA + ILoad 24 Vdc 10 % 32 mA + ILoad yes yes Accuracy 0.5 % (8-bit resolution) 0.5 % (8-bit resolution) 2.5 kV 2.5 kV 4 kVeff 0 C...+50 C -25 C...+60 C 6 mm 0.5...4 mm2 4 kVeff 0 C...+50 C -25 C...+60 C 6 mm 0.5...4 mm2 Page 305 Page 305 Overload limits, input Input resistance Voltage drop, input Output Output frequency, end value Frequency adjustment Readjustment range Output level Output current Display Decoupling diode Coordination of insulation to DIN VDE 0160, Draft 11/94 Voltage strength input/output Rated voltage Rated surge voltage Overvoltage category Voltage strength to mounting rail Operating temperature Storage temperature Overall width Conductor cross-section Dimensions and accessories see 168 Monitoring Revolutions DK LW If only one revolution limit is to be evaluated, the potentiometer for fmax must be set to end stop or the potentiometer for fmin to left stop. Then only the other is in each case active for setting the limit value. Block diagram/settings Ordering data for TS 32 for TS 35 Type Y W DK LW Cat. No. 8258680000 Initiators, NPN or PNP 1 10 - 6250 U/min. 3 switchable revolutions ranges: 10-130, 100-1300, 1000-7800 r.p.m. 2 potentiometers for upper/lower revs limit 24 Vdc = High, O V = Low 30 Vdc High >18 V, Low <7 V >0.5 ms approx. 3.5 mA (24 V) yes Output Function Output level Output current Decoupling diode Status LED Short-circuit proof Optional PNP or NPN Output active, if f within set revs limit Ub- 1.8 V 20 mA max. yes green LED no Operating voltage Power consumption Reverse polarity protection Galvanic isolation Voltage strength to mounting rail Operating temperature Storage temperature Overall width Conductor cross-section Insulation stripping length Others 24 V -10 % + 20 % <10 mA, w/o load, without initiator yes no 4 kVeff 0...+50 C -40...+60 C 12 mm 0.5...4 mm2 7 mm Initiator power supply via module possible Accessories End plate Dimensions and accessories see Type AP DKT4 Page 278 Analogue Signal Processing Technical data Input Number of inputs Input frequency Range selection Fine adjustment Input nominal level Overload limits Switching threshold Pulse duration Input current Reverse polarity protection Cat. No. 0687560000 169 Preprocessing Logic DK PL * Screw connection * logic function and time function combined * individually programmable (further functions on request) Block diagram Ordering data for TS 32 for TS 35 Y W Type on request DK PL Technical data Logical function Number of inputs Input nominal level Overload limits Switching threshold Pulse duration Input current Programmable, see note 5 24 Vdc = High, 0 V = Low 30 Vdc High >18 V, Low <7 V >1 ms approx. 1.5 mA per input (24 V) Output Output level Output current Decoupling diode Status LED Short-circuit proof PNP Ub- 1 V 20 mA max. no green LED no Operating voltage Power consumption Reverse polarity protection 24 V 20 % <10 mA yes Galvanic isolation Voltage strength to mounting rail no 4 kVeff Operating temperature Storage temperature 0 C...+50 C -40 C...+60 C Overall width Conductor cross-section Insulation stripping length 12 mm 0.5...4 mm2 7 mm Accessories End plate Ordering example: RS FLIP-FLOP Type AD DKT4 Dimensions see Page 278 * (not programmed - function next page) 170 Cat. No. 8248340000* Cat. No. 0687560000 8248340002 Remark: The module is programmed according to customers specifications. Up to 5 inputs can be linked with various logic and timer functions, e.g.: AND, OR, EXOR, NAND, NOR, EXNOR, delay elements, etc. The output is either low or high active. 824834 0001 DKPL A = (E1 OR E2) AND (E3 OR E4) AND E5 State Input 5 4 3 2 1 1 0 0 0 0 0 2 0 0 0 0 1 3 0 0 0 1 0 4 0 0 0 1 1 5 0 0 1 0 0 6 0 0 1 0 1 7 0 0 1 1 0 8 0 0 1 1 1 9 0 1 0 0 0 10 0 1 0 0 1 11 0 1 0 1 0 12 0 1 0 1 1 13 0 1 1 0 0 14 0 1 1 0 1 15 0 1 1 1 0 16 0 1 1 1 1 17 1 0 0 0 0 18 1 0 0 0 1 19 1 0 0 1 0 20 1 0 0 1 1 21 1 0 1 0 0 22 1 0 1 0 1 23 1 0 1 1 0 24 1 0 1 1 1 25 1 1 0 0 0 26 1 1 0 0 1 27 1 1 0 1 0 28 1 1 0 1 1 29 1 1 1 0 0 30 1 1 1 0 1 31 1 1 1 1 0 32 1 1 1 1 1 Output 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 1 1 1 0 1 1 1 Input Output Input 824834 0003 DKPL - Frequency divider Inputs 1 - 5 determine the divider factor Input 1 = divider factor 1: FOUT = FIN 1 Input 2 = divider factor 2: FOUT = FIN 2 Input 5 = divider factor 5: FOUT = FIN 5; FIN max. = 12 kHz Input Output 6 1 fout = fin 2 fout = fin / 2 3 fout = fin / 3 4 fout = fin / 4 5 fout = fin / 5 Note: An new divider factor can only be used if operating voltage is switched off. fin max. = 12 kHz Input 824834 0006 DKPL Input 1: FOUT = FIN Input 2: FOUT = FIN 10 Input Output 6 fout = fin fout = fin / 10 fout = fin / 50 fout = fin / 100 fout = fin / 1000 Note: A new divider factor can only be used if the operating voltage is switched off. fin max. = 3 kHz 1 2 3 4 5 Input Output Input 824834 0004 DKPL Input 1: Signal A of an incremental generator Input 2: Signal B 90 is shifted Input 3: Enable High Active Input 4: Output signal inverts High Active Input 5: No function Output: For each slope of signal A or B, the output is set to 20 - 30 Us. (I.e.: FOUT = 4xFIN) FIN max. 1 kHz 1 2 3 4 5 6 Connection A B Enable Invert Description Signal A 90 leading Fmax = 1 kHz Signal B 90 following Fmax = 1 kHz Output is released Output signal invert No function fout = 4 x fA/B (max. 4 kHz) Output Input 824834 007 DKPL Input Output 1 2 3 4 5 Out L L X X X No function H L X X X f = 1 Hz L H X X X f = 10 Hz H H X X X f = 1 Hz L -> 0 V or connection open H -> +24 ...30 Vdc X -> no effect on output function, L or H 824834 0008 DKPL Input 1 2 H H L H Output H L Input Input 2 1 0 0 0 1 1 0 1 1 Inputs 3, 4 and 5 no function Output Input Output 6 0 (is stored) No function Input 824834 0010 DKPL RS FLIP-FLOP with superior S - input (connection 2) Input connections 3, 4 and 5 must have 0 V or remain open! Connection 1 Logic Connection 2 R-Input S-Input 0 V or open Logic Connection 6 L 0 V or open L previous state is stored H L H 0 V or open +24 Vdc +24 Vdc L H H 0V +24 Vdc +24 Vdc No change of stored state No change of stored state 1 (is stored) No change of stored state Outp. +24 Vdc 0 V or open +24 Vdc Logic Output L H H Input Output Input 824834 0005 DKPL Length of input signal between 80 and 100 ms. Length of output signal 100 ms, only 2 pulses, Relation pulse-interruption 1:1. The positive slope of the input signal has to be analysed. Only input E1 is used. 824834 0501 DKPL The module allows the input frequency at connection 1 (0...max. 50 kHz) to be divided with 2 fixed divider factors. Depending on connection 2, the output frequency is transmitted from output connection 6. Connections 3, 4 and 5 have no function. Connect. 2 Logic Factor Inp. frequency Outp. frequency Connection 1 Connection 2 0 V or open L 75 0...30 kHz 0...400 Hz 24 Vdc H 27 0...10.8 kHz 0...400 Hz 171 Analogue Signal Processing 824834 0002 DKPL Inputs 1 and 2 have the function of a RS FLIP-FLOP Inputs 3, 4 and 5 have no function Threshold Monitoring DKSC 0-10 V Current sensor DKSC 0-20 mA DKI 2A * Screw connection * Mounts onto on mounting rail * Wide spectrum of functions * In part, individually adjustable Block diagram/settings S1 on on off S2 on off X DIP switch 10...100 mV 30 mV...1 V 300 mV...10 V Ordering data for TS 32 for TS 35 with combi foot TS 32/TS 35 Technical data Input signal Input resistance Voltage drop, input Cut-off frequeny Switchable input range Switching point settings Type Cat. No. Type Cat. No. Y W DKSC 0-10 V 8019640000 0...10 V 60 k 100 Hz DIL switch for 3 ranges 2 threshold Uth 1 and Uth 2 with 2 front potentiometers each 1 % Hysteresis Output Output level Output current Function Type DKI 2A DKI 2A Cat. No. 8017400000 8017410000 DKSC 0-20 mA 8031320000 0(4)...20 mA 50 1V 100 Hz 0.1...2 A 125 mV at 2 A 2 threshold Uth 1 and Uth 2 with 2 front potentiometers each 1 % no Fixed:O N >90 mA OFF <50 mA double switch output per PNP, Ub- 1.2 V 50 mA Iin Ith2: output 2 active no 24 Vdc 20 % approx. 15 mA no 4 kVeff single switch output PNP, Ub-0.1 V 20 mA Status LED Operating voltage Power consumption Galvanic isolation Voltage strength to mounting rail double switch output per PNP, Ub- 1.2 V 50 mA Uin Uth2: output 2 active no 24 Vdc 20 % approx. 15 mA no 4 kVeff Operating temperature Storage temperature Overall width Conductor cross-section 0 C...+50 C -25 C...+60 C 6 mm 0.5...4 mm2 0 C...+50 C -25 C...+60 C 6 mm 0.5...4 mm2 -25 C...+50 C -40 C...+85 C 6 mm 0.5...4 mm2 EMC resistance Burst acc. to EN 61000-4-4 ESD acc. to EN 61000-4-2 Input/outputs Power supply Contact discharge Air discharge Test Test Test Test severity severity severity severity Accessories End plate Type AP DK5 Dimensions see Page 278 172 green LED 18...30 Vdc approx. 10 mA no 4 kVeff 4, self restoring 4, self restoring 4 3 Cat. No. 8268870000 Type AP DK5 Page 278 Cat. No. 8268870000 Type AP DKT4 Page 278 Cat. No. 0687560000 Threshold Monitoring MCZ SC 0...10 Vdc MCZ SC 0...20 mA The Setpoint Controller allows cost effective units to be built for monitoring analogue signals. An upper and lower limit value, which covers the entire signal range, can be set by the user via 2 potentiometers. The respective statuses of the upper and lower limit value are indicated at the 2 digital outputs (upper limit value under/over flow; lower limit value under/over flow). Block diagram Type MCZ SC 24 V/0...10V Technical data Voltage supply Supply voltage Supply current 24 Vdc 20 % 15 mA 24 Vdc 20 % 15 mA 0...10 V 60 k 0.5...20 mA 50 1V 40 mA 100 Hz Input Input voltage Input resistance Voltage drop at full scale Max. input current Cut-off frequeny Transmission behaviour Threshold voltage ranges of Uth Cat. No. 8260280000 100 Hz Type MCZ SC 24 V/0...20 mA S1 S2 Temperature coefficient Tk 10...100 mV on on 500 ppm max. 0.03...1 V on off 250 ppm max. 0.3...10 V off x 250 ppm max. via 2 potentiometers (12 turns) 1 % of the end value active High for UInput < Uth1 (set via P1) active High for UInput > Uth2 (set via P2) < 250 s (switch threshold at 90% of the max. input signal; RL 1 k) Temperature coefficient Tk 250 ppm max. Output Output current per output Voltage drop at output transistor 2 channel switching PNP max. 50 mA < 1.2 V at 50 mA 2 channel switching PNP max. 50 mA < 1.2 V at 50 mA Insulation coordination/safe separation to EN 50178 Separation input / output Dielectric strength I/O to mounting rail none 4 kVeff / 1 min none 4 kVeff / 1 min Ambient temperature Storage temperature Conductor Conductor cross-section Approvals Overall width Dimensions and accessories see 0 C...+50 C -25 C...+60 C AWG 22...12 1.5 mm2 CE, UL, CSA 6 mm Page 305 0 C...+50 C -25 C...+60 C AWG 22...12 1.5 mm2 CE, UL, CSA 6 mm Page 305 Setting of switching threshold Hysteresis of switching threshold Function of output 1 Function of output 2 Response time Cat. No. 8227350000 Analogue Signal Processing Ordering data for TS 35 via 2 potentiometers (12 turns) 1 % of the end value active High for IInput < I th1 (set via P1) active High for IInput > I th2 (set via P2) < 250 s (switch threshold at 90% of the max. input signal; RL 1 k) 173 Passive Isolator DC/DC WAVEANALOG DC/DC input loop powered galvanic isolation 1-, 2-channel versions low power consumption safe separation CCC LP (1 channel) CCC LP (2 channel) 0(4) ... 20 mA / 0(4) ... 20 mA 0(4) ... 20 mA / 0(4) ... 20 mA Type WAS5 CCC LP WAZ5 CCC LP Type Approvals: Block diagram Ordering data Screw connection 1 channel Tension clamp connection 1 channel Screw connection 2 channel Tension clamp connection 2 channel Input/output Cat. No. 8444950000 8444960000 Cat. No. 0(4) ... 20 mA / 0(4) ... 20 mA WAS5 CCC LP 8463580000 WAZ5 CCC LP 8463590000 0(4) ... 20 mA / 0(4) ... 20 mA Temperature coefficient Set time Residual ripple Chopper frequency 0 ... 20 mA (4 ... 20 mA) 18 V 50 mA < 100 A approx. 3 V at RL= 0 Iin = 20 mA approx. 13 V at RL= 500 at Iin = 20 mA 0 ... 20 mA (4 ... 20 mA) 500 < 0.1% of FS < 0.1% from measurement value per 100 load resistance 50 ppm / K of FS 4.5 ms at 500 working resistance < 20 mVeff approx. 170 kHz 0 ... 20 mA (4 ... 20 mA) 18 V 50 mA < 100 A approx. 3 V at RL= 0 Iin = 20 mA approx. 13 V at RL= 500 at Iin = 20 mA 0 ... 20 mA (4 ... 20 mA) 500 < 0.1% of FS < 0.1% from measurement value per 100 load resistance 50 ppm / K of FS 4.5 ms at 500 working resistance < 20 mVeff approx. 170 kHz General Operating temperature Storage temperature Dimensions L / H / W mm Approvals -25 C ... +70 C -40 C ... +80 C 92.4 / 112.5 / 17.5 CE, UL, CSA, GL -25 C ... +70 C -40 C ... +80 C 92.4 / 112.5 / 17.5 CE, UL, CSA, GL Technical data* (per channel) Input signal Input voltage max. Input current max Operating current Voltage drop Output signal Load resistance Accuracy at Tu=23 C Influence of load resistance Coordination of insulation according to EN 50178, 04/98 (safe separation) Rated voltage 300 V Rated surge voltage 6 kV Overvoltage category III Contamination class 2 Clearance and creepage distance 5.5 mm Isolation voltage, voltage strength Input/output, channel / channel 4 kVeff / 1 s Input/output to mounting rail 4 kVeff / 1 min Standards/specifications EN 50178 (safe separation) EMC standards EN 50081, EN 50082, Dimensions and accessories see *TU = 23 C single module 174 EN 55011 Page 298 + 308 300 V 6 kV III 2 5.5 mm 4 kVeff / 1 s 4 kVeff / 1 min EN 50178 (safe separation) EN 50081, EN 50082, EN 55011 Page 298 + 308 DC/DC-Signal Conditioners CCC DC CCC DC CVC DC 4 ... 20 mA / 4 ... 20 mA 4 ... 20 mA / 0 ... 20 mA 4 ... 20 mA / 0 ... 10 V Ordering data Screw connection Tension clamp connection Input/output Type Cat. No. WAS4 CCC DC 8444980000 WAZ4 CCC DC 8444990000 4 ... 20 mA / 4...20 mA Type Cat. No. WAS4 CCC DC 8445010000 WAZ4 CCC DC 8445020000 4 ... 20 mA / 0 ... 20 mA Type Cat. No. WAS4 CVC DC 8445040000 WAZ4 CVC DC 8445050000 4 ... 20 mA / 0 ... 10V Technical data* Input signal Input voltage max. Input current max Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 4 ... 20 mA 7V 25 mA 4 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 30 ms (typ. 20 ms) 15 Hz (typ. 20 Hz) 4 ... 20 mA 7V 25 mA 0 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 30 ms (typ. 20 ms) 15 Hz (typ. 20 Hz) 4 ... 20 mA 7V 25 mA 0 ... 10 V 1 k 0.2% of FS 250 ppm / K of FS 30 ms (typ. 20 ms) 15 Hz (typ. 20 Hz) 24 Vdc 20% (19.2 ... 28.8 Vdc) < 32 mA at Iout = 20 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 24 Vdc 20% (19.2 ... 28.8 Vdc) < 32 mA at Iout = 20 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 24 Vdc 20% (19.2 ... 28.8 Vdc) < 20 mA at Iout = 10 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 4 kVeff / 1 min 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 Dimensions and accessories see *TU = 23 C single module Page 298 + 308 Page 298 + 308 Page 298 + 308 WAVEANALOG DC/DC voltage supply on output side 2-way-isolation analogue signal conditioning galvanic isolation between input/output signal Input loop powered cross-connectable voltage supply via cross-connectors Approvals: General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Isolation voltage, voltage strength Input/output to mounting rail Analogue Signal Processing Block diagram 175 DC/DC-Signal Conditioners CCC DC CCC DC CVC DC 0 ... 20 mA / 0 ... 20 mA 0 ... 20 mA / 4 ... 20 mA 0 ... 20 mA / 0 ... 10 V Ordering data Screw connection Tension clamp connection Input/output Type Cat. No. WAS4 CCC DC 8445070000 WAZ4 CCC DC 8445080000 0 ... 20 mA / 0 ... 20 mA Type Cat. No. WAS4 CCC DC 8446970000 WAZ4 CCC DC 8446990000 0 ... 20 mA / 4 ... 20 mA Type Cat. No. WAS4 CVC DC 8447020000 WAZ4 CVC DC 8447030000 0 ... 20 mA / 0 ... 10 V Technical data* Input signal Input current max Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 0 ... 20 mA 25 mA 50 0 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 30 ms (typ. 16 ms) 15 Hz (typ. 25 Hz) 0 ... 20 mA 25 mA 50 4 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 30 ms (typ. 16 ms) 15 Hz (typ. 25 Hz) 0 ... 20 mA 25 mA 50 0 ... 10 V 1 k 0.2% of FS 250 ppm / K of FS 30 ms (typ. 16 ms) 15 Hz (typ. 25 Hz) 24 Vdc 20% (19.2 ... 28.8 Vdc) < 11 mA at Iin = 20 mA < 32 mA at Iout = 20 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 24 Vdc 20% (19.2 ... 28.8 Vdc) < 11 mA at Iin = 20 mA < 32 mA at Iout = 20 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 24 Vdc 20% (19.2 ... 28.8 Vdc) < 11 mA at Iin = 20 mA < 20 mA at Iout = 10 V 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 4 kVeff / 1 min 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 Page 298 + 308 WAVEANALOG DC/DC voltage supply on both sides 2-way-isolation analogue signal conditioning galvanic isolation between input/output signal cross-connectable voltage supply via cross-connectorss Approvals: Block diagram General Voltage supply Power consumption input Power consumption output Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Isolation voltage, voltage strength Input/output to mounting rail *TU = 23 C single module 176 DC/DC Signal Conditioners VCC DC VCC DC VVC DC 0 ... 10 V / 0 ... 20 mA 0 ... 10 V / 4 ... 20 mA 0 ... 10 V / 0 ... 10 V Ordering data Screw connection Tension clamp connection Input/output Type Cat. No. WAS4 VCC DC 8447050000 WAZ4 VCC DC 8447080000 0 ... 10 V / 0 ... 20 mA Type Cat. No. WAS4 VCC DC 8447100000 WAZ4 VCC DC 8447110000 0 ... 10 V / 4 ... 20 mA Type WAS4 VVC DC WAZ4 VVC DC 0 ... 10 V / 0 ... Technical data* Input signal Input voltage max. Input resistance Output signal Load resistance Accuracy at Tu=23C Temperature coefficient Response time Cut-off frequeny (-3 dB) 0 ... 10 V 15 V 500 k 0 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 30 ms (typ. 25 ms) 13 Hz (typ. 17 Hz) 0 ... 10 V 15 V 500 k 4 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 30 ms (typ. 25 ms) 13 Hz (typ. 17 Hz) 0 ... 10 V 15 V 500 k 0 ... 10 V 1 k 0.2% of FS 250 ppm / K of FS 30 ms (typ. 25 ms) 13 Hz (typ. 17 Hz) 24 Vdc 20% (19.2 ... 28.8 Vdc) < 11 mA at Uin = 10 V < 32 mA at Iout = 20 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 24 Vdc 20% (19.2 ... 28.8 Vdc) < 11 mA at Uin = 10 V < 32 mA at Iout = 20 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 24 Vdc 20% (19.2 ... 28.8 Vdc) < 11 mA at Uin = 10 V < 20 mA at Iout = 10 mA 2A 0 C ... +55 C (mounted) -20 C ... +85 C 92.4 / 112.5 / 12.5 CE, UL, CSA 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 4 kVeff / 1 min 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 Page 298 + 308 WAVEANALOG DC/DC voltage supply on both sides 2-way-isolation analogue signal conditioning galvanic isolation between input/output signal cross-connectable voltage supply via cross-connectors Approvals: Block diagram Power consumption input Power consumption output Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Isolation voltage, voltage strength Input/output to mounting rail Analogue Signal Processing General Voltage supply Cat. No. 8447130000 8447140000 10 V *TU = 23 C single module 177 NEW DC/DC Signal Conditioners CCC CCC CVC 0 ... 20 mA / 0 ... 20 mA 0 ... 20 mA / 4 ... 20 mA 0 ... 20 mA / 0 ... 10 V Ordering data Screw connection Tension clamp connection Input/output Type WAS5 CCC WAZ5 CCC 0 ... 20 mA / 0 Type Cat. No. WAS5 CCC 8540250000 WAZ5 CCC 8540260000 0 ... 20 mA / 4 ... 20 mA Type Cat. No. WAS5 CVC 8540270000 WAZ5 CVC 8540280000 0 ... 20 mA / 0 ... 10 V Technical data** Input signal Input current max Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 0 ... 20 mA 25 mA 110 0 ... 20 mA 600 0.2% 250 ppm / K 45 ms 10 Hz 0 ... 20 mA 25 mA 110 4 ... 20 mA 600 0.2% 250 ppm / K 45 ms 10 Hz 0 ... 20 mA 25 mA 110 0 ... 10 V 1 k 0.2% 250 ppm / K 45 ms 10 Hz 24 Vdc 25% (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 24 Vdc 25% (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 24 Vdc 25% (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.3 W at Iout = 5 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 1 nF 1 nF 1 nF 4 kVeff / 1 min 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 Page 298 + 308 WAVEANALOG DC/DC 3-way-isolation analogue signal conditioning indication LED cross-connectable voltage supply via cross-connectors Approvals: Block diagram General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Coupling capacity Input / output to supply Isolation voltage, voltage strength Input/output to mounting rail ** TU = 23 C single module * Input/output 4 ... 20 mA/4 ... 20 mA possible 178 Cat. No. 8540180000* 8540190000* ... 20 mA NEW DC/DC Signal Conditioners WAVEANALOG DC/DC 3-way-isolation analogue signal conditioning indication LED cross-connectable voltage supply via cross-connectors CCC CVC 4 ... 20 mA / 0 ... 20 mA 4 ... 20 mA / 0 ... 10 V Approvals: Block diagram Type WAS5 CCC WAZ5 CCC 4 ... 20 mA / 0 ... 20 mA Technical data Input signal Input current max Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 4 ... 20 mA 25 mA 110 0 ... 20 mA 600 0.2% 250 ppm / K 45 ms 10 Hz 4 ... 20 mA 25 mA 110 0 ... 10 V 1 k 0.2% 250 ppm / K 45 ms 10 Hz 24 Vdc 25% (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 24 Vdc 25% (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.3 W at Iout = 5 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 1 nF 1 nF 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 General* Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Coupling capacity Input / output to supply Isolation voltage, voltage strength Input/output to mounting rail Cat. No. 8540200000 8540210000 Type WAS5 CVC WAZ5 CVC 4 ... 20 mA / 0 ... 10 V Cat. No. 8540230000 8540240000 Analogue Signal Processing Ordering data Screw connection Tension clamp connection Input/output *TU = 23 C single module 179 NEW DC/DC Signal Conditioners VCC VCC VVC 0 ... 10 V / 0 ... 20 mA 0 ... 10 V / 4 ... 20 mA 0 ... 10 V / 0 ... 10 V Ordering data Screw connection Tension clamp connection Input/output Type WAS5 VCC WAZ5 VCC 0 ... 10 V / 0 ... Type WAS5 VCC WAZ5 VCC 0 ... 10 V / 4 ... Type WAS5 VVC WAZ5 VVC 0 ... 10 V / 0 ... Technical data* Input signal Input voltage max. Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 0 ... 10 V 15 V typ. 100 k 0 ... 20 mA 600 0.2% 250 ppm / K 45 ms 10 Hz 0 ... 10 V 15 V typ. 100 k 4 ... 20 mA 600 0.2% 250 ppm / K 45 ms 10 Hz 0 ... 10 V 15 V typ. 100 k 0 ... 10 V 1 k 0.2% 250 ppm / K 45 ms 10 Hz 24 Vdc 25% (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 24 Vdc 25% (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 24 Vdc 25%) (18 Vdc ... 24 Vdc ... 30 Vdc) < 1.3 W at Iout = 5 mA 2A 0 C ... +55 C when mounted horizontally -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 1 nF 1 nF 1 nF 4 kVeff / 1 min 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 Page 298 + 308 WAVEANALOG DC/DC 3-way-isolation analogue signal conditioning indication LED cross-connectable voltage supply via cross-connectors Approvals: Block diagram General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Coupling capacity Input / output to supply Isolation voltage, voltage strength Input/output to mounting rail *TU = 23 C single module 180 Cat. No. 8540310000 8540320000 20 mA Cat. No. 8540290000 8540300000 20 mA Cat. No. 8540330000 8540340000 10 V DC/DC Signal Conditioners CCC HF CCC HF CVC HF 0 ... 20 mA / 0 ... 20 mA 0 ... 20 mA / 4 ... 20 mA 0 ... 20 mA / 0 ... 10 V Ordering data Screw connection Tension clamp connection Input/output Type Cat. No. WAS5 CCC HF 8447160000* WAZ5 CCC HF 8447170000* 0 ... 20 mA / 0 ... 20 mA Type Cat. No. WAS5 CCC HF 8447190000 WAZ5 CCC HF 8447200000 0 ... 20 mA / 4 ... 20 mA Type Cat. No. WAS5 CVC HF 8447220000 WAZ5 CVC HF 8447230000 0 ... 20 mA / 0 ... 10 V Technical data** Input signal Input current max Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 0 ... 20 mA 50 mA 50 0 ... 20 mA 500 < 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) 0 ... 20 mA 50 mA 50 4 ... 20 mA 500 < 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) 0 ... 20 mA 50 mA 50 0 ... 10 V 2 k < 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals 24 Vdc 25% (18 ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 24 Vdc 25% (18 ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 24 Vdc 25% (18 ... 30 Vdc) < 1.3 W at Iout = 5 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 1 nF 1 nF 1 nF 4 kVeff / 1 min 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082, EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 Page 298 + 308 WAVEANALOG DC/DC 20 kHz 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors Approvals: Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Coupling capacity Input / output to supply Isolation voltage, voltage strength Input/output to mounting rail Analogue Signal Processing Block diagram **TU = 23 C single module * Input/output 4 ... 20 mA/4 ... 20 mA possible 181 DC/DC Signal Conditioners WAVEANALOG DC/DC 20 kHz 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors CCC HF CVC HF 4 ... 20 mA / 0 ... 20 mA 4 ... 20 mA / 0 ... 10 V Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Type WAS5 CCC HF WAZ5 CCC HF 4 ... 20 mA / 0 ... 20 mA Technical data* Input signal Input current max Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 4 ... 20 mA 50 mA 50 0 ... 20 mA 500 < 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) 4 ... 20 mA 50 mA 50 0 ... 10 V 2 k < 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals 24 Vdc 25% (18 ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 24 Vdc 25% (18 ... 30 Vdc) < 1.3 W at Iout = 5 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 1 nF 1 nF 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082 EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Coupling capacity Input / output to supply Isolation voltage, voltage strength Input/output to mounting rail *TU = 23 C single module 182 Cat. No. 8447250000 8447260000 Type WAS5 CVC HF WAZ5 CVC HF 4 ... 20 mA / 0 ... 10 V Cat. No. 8447280000 8447290000 DC/DC Signal Conditioners WAVEANALOG DC/DC 20 kHz 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors VCC HF VCC HF 0 ... 10 V / 0 ... 20 mA 0 ... 10 V / 4 ... 20 mA Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Type WAS5 VCC HF WAZ5 VCC HF 0 ... 10 V / 0 ... 20 mA Technical data* Input signal Input voltage max. Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 0 ... 10 V 15 V 500 k 0 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) 0 ... 10 V 15 V 500 k 4 ... 20 mA 500 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals 24 Vdc 25% (18 ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 24 Vdc 25% (18 ... 30 Vdc) < 1.5 W at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 1 nF 1 nF 4 kVeff / 1 min 4 kVeff / 1 min Standards/specifications EMC standards EN 50178 EN 50081, EN 50082, EN 55011 EN 50178 EN 50081, EN 50082 EN 55011 Dimensions and accessories see Page 298 + 308 Page 298 + 308 Type WAS5 VCC HF WAZ5 VCC HF 0 ... 10 V / 4 ... 20 mA Cat. No. 8447340000 8447350000 Analogue Signal Processing Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Coupling capacity Input / output to supply Isolation voltage, voltage strength Input/output to mounting rail Cat. No. 8447310000 8447320000 *TU = 23 C single module 183 NEW DC/DC Signal Conditioners WAVEANALOG DC/DC 20 kHz 3-way-isolation transmission frequency 20 kHz analogue signal conditioning cross-connectable voltage supply via cross-connectors VVC HF VVC HF 0 ... 10 V / 0 ... 10 V -10 ... +10 V / -10 ... +10 V Approvals: Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Type WAS5 VVC HF WAZ5 VVC HF 0 ... 10 V / 0 ... 10 V Technical data* Input signal Input voltage max. Input resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Response time Cut-off frequeny (-3 dB) 0 ... 10 V 15 V 500 k 0 ... 10 V 2 k 0.2% of FS 250 ppm / K of FS 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) -10 ... + 10 V 15 V 500 k -10 ... + 10 V 2 k 0.2% of measurement range 250 ppm / K of measurement range 40 s (typ. 30 s) 15 kHz (typ. 20 kHz) General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Dimensions L / H / W mm Approvals 24 Vdc 25% (18 ... 30 Vdc) < 1.3 W at Iout = 5 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, UL, CSA 24 Vdc 25% (18 ... 30 Vdc) < 1.3 W at Iout = 5 mA 2A 0 C ... +55 C -20 C ... +85 C 92.4 / 112.5 / 17.5 CE, cUL 300 V 4 kV III 2 3 mm 300 V 4 kV III 2 3 mm 1 nF 1 nF 4 kVeff / 1 min 4 kVeff / 1 min EN 50178 EN 50081, EN 50082, EN 55011 Page 298 + 308 EN 50178 EN 50081, EN 50082, EN 55011 Page 298 + 308 Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance Coupling capacity Input / output to supply Isolation voltage, voltage strength Input/output to mounting rail Standards/specifications EMC standards Dimensions and accessories see *TU = 23 C single module 184 Cat. No. 8447370000 8447380000 Type WAS5 VVC HF WAZ5 VVC HF 10 V / 10V Cat. No. 8561610000 8587000000 NEW DC/DC Signal Conditioners (Configurable) PRO DC/DC universally adjustable via DIP switch adjustment help via Internet 3-way-isolation voltage supply from 20 - 230 V ac/dc low power loss adjustable transmission frequency indication LED Switch position/setting options Switch Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input (adjustable) Voltage uni-/bipolar adjustable Voltage calibrated ranges Current uni-/bipolar adjustable Current calibrated ranges Input resistance at current input range < 5 mA / > 5 mA at voltage input Input capacity at current input Voltage input range < 500 mV / > 500 mV Overload capacity at current input range < 5 mA / > 5 mA Voltage input range < 500 mV / > 500 mV Output (adjustable) Voltage uni-/bipolar adjustable Voltage calibrated ranges Current uni-/bipolar adjustable Current calibrated ranges Offset Load at output current at output voltage Offset Adjustment help WAVETOOL The service tool enables quick and uncomplicated configuration of WAVEANALOG PRO. Download from Internet: http://www.weidmueller.de Products Downloads (see page 192) Type WAS4 PRO DC/DC WAZ4 PRO DC/DC configurable Cat. No. 8560740000 8560750000 20 mV ... 200 V 0 ... 60 mV, 0 ... 100 mV, 0 ... 150 mV, 0 ... 300 mV, 0 ... 500 mV, 0 ... 1V, 0 ... 5V, 0 ... 10 V, 0 ... 100 V 0.1 mA ... 100 mA 0 ... 0.3 mA, 0 ... 1 mA, 0 ... 5 mA, 0 ... 16 mA, 0 ... 20 mA, 0 ... 50 mA approx. 100 / approx. 5 approx. 1 M approx. 1 nF approx. 1 nF / approx. 500 pF < 75 mA / < 300 mA max. < 20 mA / < 3 mA continuous current 0 ... 10 V 0 ... 10 V, 2 ... 10 V, 0 ... 5 V, 1 ... 5 V 0 ... 20 mV 0 ... 20 mA, 4 ... 20 mA -100%, -50%, 0%, 50%, 100% of measuring span of the chosen output range < 12 V (600 at 20 mA) < 10 mA (1 K at 10 V) 20 A and. 10 mV Residual ripple Adjustment zero pot. Adjustment span pot. Gain error Temperature coefficient Cut-off frequeny General Voltage supply Power consumption Frequency range Operating temperature Storage temperature Factory setting Dimensions L/H/B mm Weight Approvals Coordination of insulation according to EN 50178, 04/98 Rated voltage Rated surge voltage Overvoltage category Contamination class Test voltage < 10 mVeff +25% measuring span of the chosen output range 0.33 ... 3.30 x end value of chosen input range < 0.1% of FS < 60 ppm/K of FS > 10 kHz, < 10 Hz switch Standards/specifications EMC standards EN 50178 DIN EN 61326, EN 61326/A1, EN 50081-2, EN 61000-6-2 Input S1 Input range 1 2 3 0 ... 60 mV 0 ... 100 mV 0 ... 150 mV 0 ... 300 mV 0 ... 500 mV 0 ... 1 V 0 ... 5 V 0 ... 10 V 0 ... 100 V 0 ... ~0.3 mA 0 ... 1 mA 0 ... 5 mA 0 ... 10 mA 0 ... 20 mA 0 ... 50 mA 0 ... 20 mA* *Offset conversion not calibrated S2 4 1 2 3 4 Switch S2 calibrated ranges Span pot. activated: input range x 0.33 ... x 3.30 Output Output range 0 ... 10 V 2 ... 10 V 0 ... 5 V 1...5V 0 ... 20 mA 4 ... 20 mA Offset (in % of output voltage) 0% -100 % -50 % +50 % +100 % Zero pot. activated: additional 25 % 4 5 Switch S1 S3 6 7 1 2 8 S1 9 10 Switch S3 Bandwidth 10 kHz Bandwidth 10 Hz Set range can be documented on side of housing. S2 5 3 Analogue Signal Processing WAVEANALOG PRO DC/DC = on = off 20 ... 230 V ac/dc +10% approx. 1 W 48 ... 62 Hz -10 C ... +70 C -40 C ... +85 C 0 ... 10 V / 0 ... 10 V 10 Hz 92.4 / 112.5 / 12.5 approx. 100 g CE, cUL, GL 600 V 5 kV, 1.2/50 us, acc. to IEC 255-4 III 2 4 KVeff input against output against auxiliary power Dimensions and accessories see page 298 + 308 *TU = 23 C single module 185 RTD Signal Conditioners WAVEANALOG RTD 2-wire technology configurable temperature range -200 C ... +800 C Configurable output current range 0 ... 20 mA / 4 ... 20 mA cross-connectable voltage supply via cross-connectors PT100/2 PT100/2 0(4) ... 20 mA 0 ... 10 V Switch position/setting options Tmin 0 C -10 C -20 C -40 C -60 C -80 C -100 C -200 C 1 2 Output1) Range 0 ... 20 mA 4 ... 20 mA Approvals: 3 Span 40 ... 50 C 50 ... 75 C 75 ... 110 C 110 ... 165 C 165 ... 245 C 245 ... 360 C 360 ... 540 C 540 ... 800 C 1) 7 4 5 6 only modules with current output = on = off Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data*** Input signal Temperature range Supply current Conductor resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Measurement range 200 K 100 K measurement range < 200 K 40 K measurement range < 100 K General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Standards/specifications EMC standards Dimensions L / H / W mm Approvals Dimensions and accessories see * without balancing *** TU = 23 C single module Type Cat. No. WTS4 PT100/2 C 8432210000* WTZ4 PT100/2 C 8432220000* PT100/2 / 0(4) ... 20 mA Type Cat. No. WTS4 PT100/2 V 8432180000* WTZ4 PT100/2 V 8432190000* PT100/2 / 0 ... 10 V PT100/2-wire -200 ... +800 C 1.45 mA PT100/2-wire -200 ... +800 C 1.45 mA 0(4) ... 20 mA 500 0.5% of measurement range 0 ... 10 V 1 k 0.5% of measurement range 200 ppm / C (typ. 80 ppm / C) 200 ppm / C (typ. 80 ppm / C) 250 ppm / C (typ. 100 ppm / C) 500 ppm / C 250 ppm / C (typ. 100 ppm / C) 500 ppm / C 24 Vdc 20% (19.2 ... 28.8 Vdc) < 48 mA at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C 24 Vdc 20% (19.2 ... 28.8 Vdc) < 38 mA at Iout = 10 mA 2A 0 C ... +55 C -20 C ... +85 C EN 50178, IEC 751 EN 50081, EN 50082, EN 55011 92.4 / 112.5 / 12.5 CE, UL, CSA Page 298 + 308 EN 50178, IEC 751 EN 50081, EN 50082, EN 55011 92.4 / 112.5 / 12.5 CE, UL, CSA Page 298 + 308 Preconfigured modules Input Screw connection 0 ... 100 C special balancing Tension clamp connection 0 ... 100 C special balancing **You must indicate the temperature range when ordering Please indicate additional output signal of current output 186 Output 0 ... 20 mA 8432210001 8432219999** 8432220001 8432229999** 4 ... 20 mA 8432210011 8432219999** 8432220011 8432229999** 0 ... 10 V 8432180001 8432189999** 8432190001 8432199999** Aids Voltage supply 24 Vdc, 50 mA Simulator for PT 100 or precision-resistance-decade Ampere-/voltmeter which can be calibrated to an accuracy of >0.1 % of the end value. RTD Signal Conditioners WAVEANALOG RTD 3-wire technology configurable temperature range -200 C ... +800 C configurable output current range 0 ... 20 mA / 4 ... 20 mA cross-connectable voltage supply via cross-connectors PT100/3 PT100/3 0(4) ... 20 mA 0 ... 10 V Switch position/setting options Tmin 0 C -10 C -20 C -40 C -60 C -80 C -100 C -200 C 1 2 Output1) Range 0 ... 20 mA 4 ... 20 mA Approvals: 3 Span 40 ... 50 C 50 ... 75 C 75 ... 110 C 110 ... 165 C 165 ... 245 C 245 ... 360 C 360 ... 540 C 540 ... 800 C 1) 7 4 5 6 only modules with current output = on = off Ordering data Screw connection Tension clamp connection Input/output Technical data*** Input signal Temperature range Supply current Conductor resistance Output signal Load resistance Accuracy at Tu=23 C Temperature coefficient Measurement range 200 K 100 K measurement range < 200 K 40 K measurement range < 100 K General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Standards/specifications EMC standards Dimensions L / H / W mm Approvals Dimensions and accessories see * without balancing *** TU = 23 C single module Type Cat. No. WTS4 PT100/3 C 8432150000* WTZ4 PT100/3 C 8432160000* PT100/3 / 0(4) ... 20 mA Type Cat. No. WTS4 PT100/3 V 8432090000* WTZ4 PT100/3 V 8432130000* PT100/3 / 0 ... 10 V PT100/3-wire -200 ... +800 C 1.45 mA 50 0(4) ... 20 mA 500 0.5% of measurement range PT100/3-wire -200 ... +800 C 1.45 mA 50 0 ... 10 V 1 k 0.5% of measurement range 200 ppm / C (typ. 80 ppm / C) 250 ppm / C (typ. 100 ppm / C) 500 ppm / C (typ. 200 ppm / C) 200 ppm / C (typ. 80 ppm / C) 250 ppm / C (typ. 100 ppm / C) 500 ppm / C (typ. 200 ppm / C) 24 Vdc 20% (19.2 ... 28.8 Vdc) < 48 mA at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C 24 Vdc 20% (19.2 ... 28.8 Vdc) < 38 mA at Iout = 10 mA 2A 0 C ... +55 C -20 C ... +85 C EN 50178, IEC 751 EN 50081, EN 50082, EN 55011 92.4 / 112.5 / 12.5 CE, UL, CSA Page 298 + 308 EN 50178, IEC 751 EN 50081, EN 50082, EN 55011 92.4 / 112.5 / 12.5 CE, UL, CSA Page 298 + 308 Analogue Signal Processing Block diagram Preconfigured modules Input Screw connection 0 ... 100 C special balancing Tension clamp connection 0 ... 100 C special balancing ** You must indicate the temperature range when ordering Please indicate additional output signal of current output Output 0 ... 20 mA 8432150001 8432159999** 8432160001 8432169999** 4 ... 20 mA 8432150011 8432159999** 8432160011 8432169999** 0 ... 10 V 8432090001 8432099999** 8432130001 8432139999** Aids Voltage supply 24 Vdc, 50 mA Simulator for PT 100 or precision-resistance-decade Ampere-/voltmeter which can be calibrated to an accuracy of >0.1 % of the end value. 187 RTD Signal Conditioners WAVEANALOG RTD 2-, 3- and 4-wire technology configurable temperature range -200 C ... +800 C configurable output current range 0 ... 20 mA / 4 ... 20 mA cross-connectable voltage supply via cross-connectors PT100/4 PT100/4 0(4) ... 20 mA 0 ... 10 V Switch position/setting options Tmin 0 C -10 C -20 C -40 C -60 C -80 C -100 C -200 C 1 Output Range 0 ... 20 mA 4 ... 20 mA Approvals: 1) 2 3 Span 40 ... 50 C 50 ... 75 C 75 ... 110 C 110 ... 165 C 165 ... 245 C 245 ... 360 C 360 ... 540 C 540 ... 800 C 1) 100 K measurement range < 200 K 40 K measurement range < 100 K General Voltage supply Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Standards/specifications EMC standards Dimensions L / H / W mm Approvals Dimensions and accessories see * without balancing *** TU = 23 C single module WTS4 PT100/4 C 8432270000* WTZ4 PT100/4 C 8432280000* PT100/4 / 0(4) ... 20 mA Type Cat. No. Type Cat. No. WTS4 PT100/4 V 432240000* WTZ4 PT100/4 V 432250000* PT100/4 / 0 ... 10 V PT100/4-wire -200 ... +800 C 1.45 mA 50 (3- & 4-wire) 0(4) ... 20 mA 500 PT100/4-wire -200 ... +800 C 1.45 mA 50 (3- & 4-wire) 0 ... 10 V 1 k 0.1% of measurement range 0.1 K 0.2% of measurement range 0.1% of measurement range 0.1 K 0.2% of measurement range 200 ppm / C (typ. 80 ppm / C) 225 ppm / C (typ. 90 ppm / C) 450 ppm / C (typ. 180 ppm / C) 200 ppm / C (typ. 80 ppm / C) 225 ppm / C (typ. 90 ppm / C) 450 ppm / C (typ. 180 ppm / C) 24 Vdc 20% (19.2 ... 28.8 Vdc) < 48 mA at Iout = 20 mA 2A 0 C ... +55 C -20 C ... +85 C EN 50178, IEC 751 EN 50081, EN 50082, EN 55011 92.4 / 112.5 / 12.5 CE, UL, CSA Page 298 + 308 24 Vdc 20% (19.2 ... 28.8 Vdc) < 38 mA at Iout = 10 mA 2A 0 C ... +55 C -20 C ... +85 C EN 50178, IEC 751 EN 50081, EN 50082, EN 55011 92.4 / 112.5 / 12.5 CE, UL, CSA Page 298 + 308 5 6 9 10 PT 100 7 8 2 - wire 3 - wire 4 - wire only modules with current output Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data*** Input signal Temperature range Supply current Conductor resistance Output signal Load resistance Accuracy at Tu=23 C 100 K measurement range < 600 K Measurement range 100 K Measurement range 600 K Temperature coefficient Measurement range 200 K 4 = on = off Preconfigured modules Input Screw connection 0 ... 100 C special balancing Tension clamp connection 0 ... 100 C special balancing ** Please indicate the temperature range and the sensor type Please indicate additional output signal of current output 188 Output 0 ... 20 mA 8432270001 8432279999** 8432280001 8432289999** (2-, 3- or 4-wire). 4 ... 20 mA 8432270011 8432280011 0 ... 10 V 8432240001 8432249999** 8432250001 8432259999** Aids Voltage supply 24 Vdc, 50 mA Simulator for PT 100 or precision-resistance-decade Ampere-/voltmeter which can be calibrated to an accuracy of >0.1 % of the end value. NEW RTD-Signal Isolating Transformer (Configurable) WAVEANALOG PRO RTD PRO RTD Adjustment help WAVETOOL This service tool enables quick and uncomplicated configuration of WAVEANALOG PRO. Download from Internet: http: //www.weidmueller.de Products Downloads (see page 192) measurement from PT 100, Ni 100, R, potentiometer univerally adjustable via DIP switch 3-way-isolation status LED linearization cross-connectable voltage supply via cross-connectors Approvals: Block diagram Ordering data Screw connection Tension clamp connection Input/output Type WAS5 PRO RTD WAZ5 PRO RTD configurable Cat. No. 8560700000 8560710000 Selection of input Switch 1 Input 1 2 3 PT100 2-wire PT100 3-wire PT100 4-wire. R 2-wire NI100 2-wire NI100 3-wire NI100 4-wire Potentiometer min 0C -10C -20C -25C -30C -40C -50C -60C -70C -80C -90C -100C -150C -200C = on = off Selection of minimum input values Switch 1 Rmin Pot.min 4 5 6 0 0% 10 10% 20 20% 20 25% 30 30% 40 40% 50 50% 60 60% 70 70% 80 80% 90 100 150 200 7 Technical data* Output (adjustable) Output voltage Offset voltage Load resistance Output current Offset current Load resistance Accuracy, slow/fast step response Step response (switchable via DIP switch) RTD, R Potentiometer Temperature coefficient measurement range 200 K 100 K measurement range < 200 K 40 K measurement range < 100 K Max. wire resistance: Influence of wire resistances: Open circuit recognition: Range of man. fine adjustment Status LED: General Supply voltage Power consumption Current carrying capacity of cross-connection Operating temperature Storage temperature Factory setting Dimensions L/H/B mm Weight Approvals Coordination of insulation according to DIN EN 50178, 04/98 Rated voltage Surge voltage Overvoltage category Contamination class Clearance and creepage distance Test voltage Standards/specifications EMC standards Dimensions and accessories see * TU = 23 C single module PT100/2-/3-/4-wire: -200C to 850C Ni100 : -60C to +250C Potentiometer: min: 0...100 / max:0...100k Resistance: 0 ... 450 / 0...10 V max. 0.05 V 1 k 0/4 ... 20 mA max. 100 A 600 PT 100,Ni 100: 0.3% of measurement range 0.8%, Measurement range < 100 K / 0.3 K / 0.8 K Potentiometer: 0.2% of FS / 0.3% Resistance: 0.2% of FS / 0.3% typ. fast slow < 1.2 s < 2.2 s < 500 ms < 1.1 s 200 ppm / C 250 ppm / C 400 ppm / C 50 for 3- and 4-wire max. + 0.25C at 50 wire resistance Output signal > 10 V or > 20 mA, LED blinks 5%, from ver. 1: 12.5%, potentiometer 12.5 %...25 % Module active: LED lit / open circuit: LED blinks Error: LED off 18 Vdc ... 24 Vdc ... 30 Vdc 830 mW ... 880 mW ... 980mW @ Iout = 20 mA 2A 0...55C -20...85C PT 100/3 0 ... 100 C / 4 ... 20 mA No manual fine adjustment; slow step response 92.4 / 112.5 / 17.5 approx. 100 g CE, cUL, GL 300 V 4 kV III 2 3 mm 2 kVeff EN 50178, IEC751 EN 50081, EN50082, EN55011 Page 298 + 308 Special range T 40K 50K 60K 70K 80K 90K 100K 110K 120K 125K 130K 140K 150K 160K 170K 180K 190K 200K 250K 300K 350K 400K 450K 500K 550K 600K 650K 700K 750K 800K 850K 900K Selection of the measurement range Switch 2 R pot. 1 2 3 4 20 25 30 35 40 45 50 55 60 62.5 65 70 75 80 85 90 95 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 Selection of output Switch 2 Output 6 7 0...10V 0...20mA 4...20mA Selection of step set time Time of step response slow fast 5 20% 25% 30% 35% 40% 45% 50% 55% 60% 62.5% 65% 70% 75% 80% 85% 90% 95% 100% ----------------------------Switching on the manual fine adjustment S.1 man. adj.. 8 off on S.2 8 189 Analogue Signal Processing Input (adjustable) Thermo-Signal Conditioners Thermo Select WAVEANALOG Thermo thermocouples K, J, T, E, N, R, S, B configurable temperature range -200 C ... +1820 C no adjustment necessary cold junction compensation configurable output signal cross-connectable voltage supply via cross-connectors 4 ... 20 mA, 0 ... 10 V Block diagram Technical data* Input signal Types Output signal Load resistance Output signal Load resistance Output signal Load resistance Accuracy at Tu = 23 C Temperature coefficient Response time without filter Response time with filter General Voltage supply Power consumption Current carrying capacity of cross-connection Open circuit recognition Operating temperature Storage temperature Standards/specifications EMC standards Dimensions L / H / W mm Approvals Dimensions and accessories see * TU = 23 C single module 190 SW 1 Type 1 K J T E N R S B 2 SW 2 3 SW 1 Approvals: Ordering data Screw connection Tension clamp connection Input/output Switch position/setting options C / 0 ... 20 mA, Type WTS4 Thermo Select WTZ4 Thermo Select C / 0 ... 20 mA C / 4 ... 20 mA C / 0 ... 10 V Cat. No. 8432300000 8432310000 Thermocoupler acc. to IEC584 (fully insulated) K -200 ... +1372 C J -200 ... +1200 C T -200 ... +400 C E -200 ... +1000 C N -200 ... +1300 C R -50 ... +1760 C S -50 ... +1760 C B +50 ... +1820 C 0 ... 20 mA 500 4 ... 20 mA 500 0 ... 10 V 1 k Type K -200C ...-150C (5K + 0.1% of set range) -150C ...1200C (3K + 0.1% of set range) 1200C ...1372C (4K + 0.1% of set range) Type J -200C ...-150C (4K + 0.1% of set range) -150C ...1200C (3K + 0.1% of set range) Type T -200C ...-150C (5K + 0.1% of set range) -150C ...400C (3K + 0.1% of set range) Type E -200C ...-150C (4K + 0.1% of set range) -150C ...1000C (3K + 0.1% of set range) Type N -200C ...-150C (6K + 0.1% of set range) -150C ...1300C (3K + 0.1% of set range) Type R -50C ...200C (10K + 0.1% of set range) 200C ...1760C (6K + 0.1% of set range) Type S -50C ...200C (10K + 0.1% of set range) 200C ...1760C (6K + 0.1% of set range) Type B 50C ...250C (25K + 0.1% of set range) 250C ...500C (10K + 0.1% of set range) 500C ...1820C (6K + 0.1% of set range) (200 ppm v. Span + 0.075 K) /K 1.1 s 6s 24 Vdc 20% (19.2 ... 28.8 Vdc) < 38 mA at Iout = 20 mA 2A LED blinks (output value: > 20 mA and. > 10 V) 0 C ... +55 C -20 C ... +85 C EN 50178, IEC584 EN 50081, EN 50082, EN 55011 92.4 / 112.5 / 12.5 CE, UL, CSA Page 298 + 308 Tmin 4 0 C -10 C -20 C -30 C -40 C -50 C -100 C -150 C -200 C +50 C +100 C +150 C +200 C +250 C +500 C 5 SW 2 Output 6 0 - 10 V 0 - 20 mA 4 - 20 mA 7 6 7 Span 1 100 C 150 C 200 C 250 C 300 C 350 C 400 C 450 C 500 C 550 C 600 C 650 C 700 C 750 C 800 C 850 C 900 C 950 C 1000 C 1050 C 1100 C 1150 C 1200 C 1250 C 1300 C 1350 C 1400 C 1450 C 1500 C 1600 C 1700 C 1800 C Filter 8 off on = on = off 2 3 4 5 NEW Thermo Signal Isolating Transformers (Configurable) PRO Thermo Approvals: Adjustment help WAVETOOL This service tool enables quick and uncomplicated configuration of WAVEANALOG PRO. Download from the Internet: http: //www.weidmueller.de Products Downloads (see page 192) Selection the thermocoupler SW1 Type 1 2 K J T E N R S B Selection of minimum temperature SW1 min 4 5 6 7 0C -10C -20C -30C -40C -50C -100C -150C -200C +50C +100C +150C +200C +250C 500C Special range 3 Block diagram Ordering data Screw connection Tension clamp connection Input/output Technical data* Input (adjustable) Accuracy at Tu = 23 C Output (adjustable) Output voltage Offset voltage Load resistance Output current Offset current Load resistance Step response at connected filter function Max. wire resistance Open circuit recognition Range of man. fine adjustment Status LED: Type WAS5 PRO Thermo WAZ5 PRO Thermo configurable Cat. No. 8560720000 8560730000 Thermocouples acc. to EN 60584-1 Type K, J, E, N, R, S, B via DIP switch selectable Type K -200C ...-150C (5K + 0.1% of set range) -150C ...1200C (3K + 0.1% of set range) 1200C ...1372C (4K + 0.1% of set range) Type J -200C ...-150C (4K + 0.1% of set range) -150C ...1200C (3K + 0.1% of set range) Type T -200C ...-150C (5K + 0.1% of set range) -150C ...400C (3K + 0.1% of set range) Type E -200C ...-150C (4K + 0.1% of set range) -150C ...1000C (3K + 0.1% of set range) Type N -200C ...-150C (6K + 0.1% of set range) -150C ...1300C (3K + 0.1% of set range) Type R -50C ...200C (10K + 0.1% of set range) 200C ...1760C (6K + 0.1% of set range) Type S -50C ...200C (10K + 0.1% of set range) 200C ...1760C (6K + 0.1% of set range) Type B 50C ...250C (25K + 0.1% of set range) 250C ...500C (10K + 0.1% of set range) 500C ...1820C (6K + 0.1% of set range) 0...10 V Max. 0.05 V 1 K 0/4 ... 20 mA max. 100 A 600 max. 1.4 s max. 7.5 s 50 for 3- and 4-wire Output signal > 10 V or > 20 mA, LED blinks 5% Module active: LED lights up / open circuit: LED blinks Error: LED off General Supply voltage: Power consumption: Current carrying capacity of cross-connection 18 Vdc ... 24 Vdc ... 30 Vdc 800 mV ... 850 mW ... 950 mW @ I output = 20 mA 2A Operating temperature Storage temperature 0 C ... +55 C -20 ... +85 C Standards/specifications EMC standards EN 50178, IEC751 EN 50081, EN50082, EN55011 Factory setting Type K 0 ... 1000 C / 4 ... 20 mA; no filter; No manual fine adjustment 92.4 / 112.5 / 17.5 100 g CE, cUL, GL Page 298 + 308 Dimensions L/H/W mm Weight Approvals Dimensions and accessories see * TU = 23 C single module Selection of temperature span SW2 Span 1 2 3 4 100C 150C 200C 250C 300C 350C 400C 450C 500C 550C 600C 650C 700C 750C 800C 850C 900C 950C 1000C 1050C 1100C 1150C 1200C 1250C 1300C 1350C 1400C 1450C 1500C 1600C 1700C 1800C 5 Selection of output SW2 Output 6 7 0...10V 0...20mA 4...20mA Switching on the manual fine adjustment SW1 man. adjust. off on 8 Switching on the filter function SW2 Filter 8 off on Analogue Signal Processing WAVEANALOG PRO Thermo 3-way-isolation thermocouples K, J, T, E, N, R, S, B configurable temperature range -200 C ... +1820 C no adjustment necessary cold junction compensation configurable output signal cross-connectable voltage supply via cross-connectors = on = off Coordination of insulation acc. to DIN EN 50178, 04/98 Rated voltage 300 V Surge voltage 4 kV Overvoltage category III Contamination class 2 Clearance & creep. distance 3 mm Test voltage 2 kVeff 191 NEW Adjustment Help WAVETOOL The adjustment help - WAVETOOL - enables quick and uncomplicated configuration of WAVEANALOG PRO DC, WAVEANALOG PRT RTD, WAVEANALOG PRO THERMO. Menu for selecting the functions For configuring the current/voltage isolating transformer Once the required input and output parameters have been entered, the program determines the correct switch setting and gives instructions for the electrical connection of the module. Where necessary, it also determines and displays the required calibration values. The entire process can be printed out or saved as a PDF file for installation documentation purposes. Download from the Internet: http://www.weidmueller.de Products Printout of protocol for the documentation WAVE TOOL For configuring the temperature signal isolating transformer For configuring the thermo signal isolating transformer 192 Download 193 Analogue Signal Processing WAVECONTROL Current monitoring Monitoring flows of currents enables a constant control of individual devices and installation components. Discrepancies or disruptions arising in the electrical circuit can easily be evaluated as breakdowns. Targeted rectifying procedures can be taken. The WAVECONTROL range of products convert sinusoidal/non-sinusoidal AC/DC currents up to 60 A to standard analogue signals. The measurement processes are based on 2 basic principles. One principle is alternating currents up to 10 A ac and 50/60 Hz are measured using the transformer process. The module is looped directly into the measurement circuit. A Hall-effect element comes in to operation at 10 A ac/dc. The potential-free wire is inserted through the module, allowing currents up to 60 A ac/dc to be measured. Quite often, there are high-frequency parts of signals on the wire to be measured. In order to be able to take these parts of the signals into consideration, so-called TRMS converters (TRUE Root Mean Square) are connected to the Hall sensors. This enables measurements up to 2 kHz, independent of the shape of the curve. Standard signals (0...20, 4...20 mA, 4...20 A current loop supply, 0...10 V) or a switch output are on offer. Fig.: Monitoring motor currents Monitoring a motor in a cooling system Monitoring a pump in a sewage treatment plant 194 WAVECONTROL Galvanically isolated measurement circuit Measurements of direct and alternating currents possible TRMS versions for measuring non sinusoidal signals Measurement range switch without calibration Relay version with selectable hysteresis Selectable working and closed-circuit current process for defined statuses (optional as normally open or normally closed contact) Error indication via LED indication Less wiring costs thanks to crossconnections Very good marking options Fast commissioning - pluggable replacement PCBs Connection technology - screw or tension clamp via socket block Analogue Signal Processing Tool-free mounting Coding elements in the connections - false plugging not possible 195 Current Monitoring WAVECONTROL current ranges adjustable via DIP switch cross-connectable voltage supply via cross-connectors selectable hysteresis selectable working and closed-circuit current principle WAS2 CMR WAZ2 CMR WAS2 CMR WAZ2 CMR 1/5/10 A ac selectable with relay output 20/40/60A ac selectable with relay output Approvals: Block diagram Ordering data Screw connection Tension clamp connection Technical data* Input Input current Input frequency Pass through diameter Measuring principle Connection type Measurement circuit voltage Type WAS2 CMR 1/5/10A ac WAZ2 CMR 1/5/10A ac transformer coupled screw or tension clamp connection 250Vac 20A ac/40A ac/60A ac selectable (without additional adjustment) 50Hz/60Hz 8mm Contact-free current monitoring using Hall sensor Push-through connection 400Vac, higher voltages dependent on wire insulation Max. measuring circuit Output Contact set Min. switching voltage Max. switching voltage Continuous current AC Continuous current DC Max. switching current Min. switching current Status LED Threshold Hysteresis Temperature coefficient Response time (10 ... 90%) Working/closed-circuit current principle Coordination of insulation acc. to DIN EN 50178, 04/98 Rated voltage Surge voltage Overvoltage category Contamination class Clearance and creepage distance Test voltage 100A for 1s dependent on wire cross-section 1 changeover contact 6Vdc/6Vac 60Vdc/250Vac 3A 0.7A 7A 100mA green LED 10% ... 100% adjustable via front potentiometer approx. 5% or approx. 10% selectable from set threshold 800 ppm/K typ. 700 ms selectable 1 changeover contact 6Vdc/6Vac 60Vdc/250Vac 3A 0.7A 7A 100mA green LED 10% ... 100% adjustable via front potentiometer approx. 5% or approx. 10% selectable from set threshold 250 ppm/K typ. 700 ms selectable 300V 4KV lll 2 3 mm 4kV eff 300V 4KV lll 2 3 mm 4kV eff 21.6Vdc...24Vdc...26.4Vdc 8.3 mA (relay not switched) 24 mA (relay switched) yes 2A 0 ... 50C -20 ... +70C Input range: 5A ac; hysteresis 10%, working current principle 92.4/112.4/22.5 150g CE, cUL Page 298 + 308 21.6Vdc...24Vdc...26.4Vdc 23 mA (relay not switched) 47 mA (relay switched) yes 2A 0 ... 50C -20 ... +70C Input range :40A ac; hysteresis 10% working current principle 92.4/112.4/22.5 150g CE, cUL Page 298 + 308 General Supply Supply voltage Power consumption at rated voltage Reverse polarity protection Current carrying capacity of the cross-connection Operating temperature range Storage/transport Factory setting Dimensions L/H/B (mm) Weight Approvals Dimensions and accessories see * TU = 23 C single module 196 Cat. No. 8516560000 8516570000 Qty. 1 1 1A ac/5A ac/10A ac selectable (without additional adjustment) 50Hz/60Hz Type WAS2 CMR 20/40/60A ac WAZ2 CMR 20/40/60A ac Cat. No. 8513340000 8526600000 Qty. 1 1 Current Monitoring WAVECONTROL input and output range adjustable via DIP switch no calibration required cross-connectable voltage supply via cross-connectors WAS1 CMA WAZ1 CMA WAS1 LP CMA WAZ1 LP CMA 1/5/10A ac selectable with analogue output 0...20 mA / 4...20 mA 0...10 V 1/5/10 A ac selectable with analogue output 4...20 mA loop powered Approvals: Block diagram Ordering data Screw connection Tension clamp connection Type WAS1 CMA 1/5/10A ac WAZ1 CMA 1/5/10A ac Technical data* Input Input current Input frequency Accuracy Measuring principle Connection type Measurement circuit voltage Max. measuring circuit Output Current/voltage selectable 1 A ac/5 A ac/10 A ac selectable (without additional adjustment) 50 Hz/60 Hz 0.5% FSR transformer coupled Screw or tension clamp connection 250 Vac 100 A for 1s 1A ac/5A ac/10A ac selectable (without additional adjustment) 50 Hz/60 Hz 0.5% FSR transformer coupled Screw or tension clamp connection 250 Vac 100 A for 1s 0 ... 10 V 0 ... 20 mA 4 ... 20 mA 0 ... 10 V max. 0.05 V 1 K approx. 13 V and 24 mA 0/4 ... 20 mA max.100 A 600 4 ... 20mA current loop supply Status LED Temperature coefficient Response time (10 ... 90%) Coordination of insulation acc. to DIN EN 50178, 04/98 (safe separation) Rated voltage Surge voltage Overvoltage category Contamination class Clearance and creepage distance Test voltage General Supply Supply voltage Power consumption at rated voltage Reverse polarity protection Operating temperature range Storage/transport Factory setting Dimensions L/H/W (mm) Weight Approvals Dimensions and accessories see * TU = 23 C single module Qty. 1 1 Type WAS1 LP CMA 1/5/10A ac WAZ1 LP CMA 1/5/10A ac Cat. No. 8528650000 8528660000 green LED ON-> OK; blinks -> signal out of range; OFF -> Error 200 ppm/K typ. 700 ms approx. 24 mA 4 ... 20 mA max. 100 A 550 (at 24 V) RL = (Vcc - 13V) / 20 mA Dependent on voltage Vcc green LED ON-> OK; blinks -> signal out of range; OFF -> Error 200 ppm/K typ. 700 ms 300V 6KV lll 2 5.5 mm 4kV eff 300V 6KV lll 2 5.5 mm 4kV eff 21.6 Vdc...24 Vdc...26.4 Vdc 40 mA at Iout = 20 mA yes 13 Vdc ... 30 Vdc 0 ... 50C - 20 ... + 70C 0 ... 5A ac; 4 ... 20mA 72/92.4/22.5 150g CE, cUL Page 298 + 308 0 ... 50C -20 ... +70C 0 ... 5A ac; 4 ... 20mA 72/92.4/22.5 150g CE, cUL Page 298 + 308 Qty. 1 1 Analogue Signal Processing Output voltage Offset voltage Load resistance Output signal limit Output current Offset current Load resistance Cat. No. 8523400000 8523410000 yes 197 Current Monitoring WAVECONTROL input and output range adjustable via DIP switch no calibration required true TRMS value measurements hall sensor measurement method WAS2 CMA WAZ2 CMA WAS2 CMA WAZ2 CMA 5/10A ac/dc selectable with analogue output 0 ... 20 mA/ 4 ... 20 mA/ 0 ... 10 V 20/25/30A ac/dc selectable with analogue output 0 ... 20 mA/ 4 ... 20 mA/ 0 ... 10 V Approvals: Block diagram Input / Output configurable Ordering data Screw connection Tension clamp connection Technical data* Input Input current Input frequency Accuracy Measuring principle Connection type Pass through diameter Measurement circuit voltage Max. measuring circuit Output Current/voltage selectable Output voltage Offset voltage Load resistance Output signal limit Output current Offset current Load resistance Status LED Temperature coefficient Response time (10 ... 90%) Coordination of insulation acc. to DIN EN 50178, 04/98 (safe separation) Rated voltage Surge voltage Overvoltage category Contamination class Clearance and creepage distance Test voltage General Supply Supply voltage Power consumption at rated voltage Reverse polarity protection Operating temperature range Storage/transport Factory setting Dimensions L/H/B (mm) Weight Approvals Dimensions and accessories see * TU = 23 C single module 198 Type WAS2 CMA 5/10A uc WAZ2 CMA 5/10A uc Cat. No. 8526610000 8526620000 Qty. 1 1 Type WAS2 CMA 20/25/30A uc WAZ2 CMA 20/25/30A uc Cat. No. 8545830000 8545840000 5 A uc/10 A uc selectable (without additional adjustment) 0 Hz - 2 kHz (True RMS to DC Converter) 1% (0 Hz - 1 kHz) Crest factor 3 FSR 2% (0 Hz - 2 kHz) Crest factor 5 FSR Contact-free current monitoring using Hall sensor Push-through connection 8 mm 400 Vac, higher voltages dependent on wire insulation 20/25/30 A uc selectable (without additional adjustment) 0 Hz - 2 kHz (True RMS to DC Converter) 1% (0Hz - 1KHz) Crest factor 3 FSR 2% (0Hz - 2KHz) Crest factor 5 FSR Contact-free current monitoring using Hall sensor Push-through connection 8 mm 400 Vac, higher voltages dependent on wire insulation dependent on wire cross-section dependent on wire cross-section 0 ... 10 V 0 ... 20 mA 4 ... 20 mA 0 ... 10 V max. 0.08 V 1 K approx. 13 V and. 24 mA 0/4 ... 20 mA max.150 A 600 green LED ON-> OK; blinks -> signal out of range; OFF -> Error 650 ppm/K typ. 700 ms 0 ... 10 V 0 ... 20 mA 4 ... 20 mA 0 ... 10 V max. 0.08 V 1 K approx. 13 V and. 24 mA 0/4 ... 20 mA max.150 A 600 green LED ON-> OK; blinks -> signal out of range; OFF -> Error 650 ppm/K typ.700 ms 300 V 6 KV lll 2 5.5 mm 4 kV eff 300 V 6 KV lll 2 5.5 mm 4 kV eff 21.6 Vdc...24 Vdc...26.4 Vdc 50 mA at Iout = 20 mA yes 21.6 Vdc...24 Vdc...26.4 Vdc 50 mA at Iout = 20 mA yes 0 ... 50 C -20 ... +70 C 0 ... 5A uc; 4 ... 20 mA 92.4/112.4/22.5 150 g CE, cUL Page 298 + 308 0 ... 50 C -20 ... +70 C 0 ... 25 A uc; 4 ... 20mA 92.4/112.4/22.5 150g CE, cUL Page 298 + 308 Qty. 1 1 Current Monitoring WAVECONTROL input and output range adjustable via DIP switch no calibration required cross-connectable voltage supply via cross-connectors true TRMS value measurements hall sensor measurement method WAS2 CMA WAZ2 CMA 40/50/60A ac/dc selectable with analogue output 0 ... 20 mA/ 4 ... 20 mA/ 0 ... 10 V Approvals: Block diagram Measuring principle Connection type Pass through diameter Measurement circuit voltage Max. measuring circuit Output Current/voltage selectable Output voltage Offset voltage Load resistance Output signal limit Output current Offset current Load resistance Status LED Temperature coefficient Response time (10 ... 90%) Coordination of insulation acc. to DIN EN 50178, 04/98 (safe separation) Rated voltage Surge voltage Overvoltage category Contamination class Clearance and creepage distance Test voltage General Supply Supply voltage Power consumption at rated voltage Reverse polarity protection Operating temperature range Storage/transport Factory setting Dimensions L/H/W (mm) Weight Approvals Dimensions and accessories see * TU = 23 C single module Type WAS2 CMA 40/50/60A uc WAZ2 CMA 40/50/60A uc Cat. No. 8513330000 8526590000 Qty. 1 1 40/50/60A uc selectable (without additional adjustment) 0 Hz - 2 kHz (True RMS to DC Converter) 1% (0Hz - 1KHz) Crest factor 3 FSR 2% (0Hz - 2KHz) Crest factor 5 FSR Contact-free current monitoring using Hall sensor Push-through connection 8 mm 400 Vac, higher voltages dependent on wire insulation dependent on wire cross-section 0 ... 10 V 0 ... 20 mA 4 ... 20 mA 0 ... 10V max. 0.08 V 1 k approx. 13 V and. 24 mA 0/4 ... 20 mA max.150 A 600 green LED ON-> OK; blinks -> signal out of range; OFF -> Error 650 ppm/K type 700 ms Analogue Signal Processing Ordering data Screw connection Tension clamp connection Technical data* Input Input current Input frequency Accuracy 300 V 6 KV lll 2 5.5 mm 4 kV eff 21.6 Vdc...24 Vdc...26.4 Vdc 50 mA at I out = 20 mA yes 0 ... 50C -20 ... +70C 0 ... 50 A uc; 4 ... 20 mA 92.4/112.4/22.5 150 g CE, cUL Page 298 + 308 199 Current Monitoring SMSI DC O * For AC/DC * With and without adjustable switching threshold * Opto-coupler output This series is particularly suitable for monitoring small currents from 50 mA to 5 A. With adjustable switching threshold Up to 50 mA Up to 250 mA Type Cat. No. SMSI 0.05 DC O 1157160000 Type Cat. No. SMSI 0.25 DC O 1156360000 10 V... 250 Vdc 70 mA 200 mW - 1 mA...50 mA 0.5 % (50 mA)...5 % (1 mA) < 10 ms < 10 ms <4V 5 V...50 Vdc 100 mA 1.3 V 10 V... 250 Vdc 350 mA 750 mW - 40 mA...250 mA 2% (250 mA)...10% (40 mA) < 3 ms < 3 ms <3V 5 V...50 V- 100 mA 1.3 V -25 C...+60 C -25 C...+60 C -25 C...+40 C -25 C...+50 C -25 C...+40 C -25 C...+50 C Block diagram/ timing diagram The adjustable switching threshold activates optionally one relay-or opto-coupler output each. Ordering data Technical data Measurement circuit voltage Max. permissible current in measurement circuit Rated consumption - (W) Rated consumption ~ (VA) Adjustable switching threshold Hysteresis between turn-on and turn-off point Activation time tA Reaction time tR Voltage drop at input Output voltage Max. continuous output current Saturation voltage Auxiliary voltage Auxiliary voltage rated consumption Auxiliary voltage rated data Adjustable threshold switching on switching off Hysteresis Storage temperature Ambient temperature -, assembled without spacing on TS -, assembled with 20 mm spacing on TS Coordination of insulation according to VDE, Draft 11/94 Overvoltage category, input Overvoltage category, output Overvoltage category, input 1-input 2, Output 1-output 2, input-output Contamination class II I III 2 Dimensions and connection data see page 306 + 307 Fig. V II I III 2 Relay 200 Fig. V SMSI AC O SMSI AC O SMSI AC With adjustable switching threshold Current monitoring units with transistor output up to 5 A Current monitoring with indicator up to 5 A up to 250 mA Up to 2.5 A without switching threshold without switching threshold Type Cat. No. SMSI 0.25 AC O 1156460000 Type Cat. No. SMSI 2.5 AC O 1157360000 Type SMSI 5 AC O 10 V...250 Vac 300 mA - 1075 mVA 40 mA...250 mA 5% 40 ms 15 ms < 4.3 V~eff (I = 250 mA) 5 V...50 V- 100 mA 1.3 V 10 V...250 Vac 2.8 A - 250 mVA 0.2 A...2.2 A approx. 35% 55 ms 20 ms < 100 mV~eff (I = 10 A) 5 V...50 V- 100 mA 1.3 V 24 Vuc 10% 550 mW-/1150 mVA~ 23 mA-/47 mA~ 5...250 Vav 1 A...5 A 10 ms 20 ms < 200 mV 24 Vuc 10% 100 mA < 3.2 V 5...250 Vac 1 A...5 A 10 ms 20 ms < 200 mV 5...48 Vdc 100 mA < 1.6 V 5...250 Vac 1 A...5 A < 200 mV -25 C...+60 C -25 C...+60 C -40 C...+60 C -40 C...+60 C -40 C...+60 C -25 C...+40 C -25 C...+50 C -25 C...+40 C -25 C...+50 C -25 C...+40 C -25 C...+50 C -25 C...+40 C -25 C...+50 C -25 C...+40 C -25 C...+50 C II I II I II I II I II I III 2 III 2 III 2 III 2 III 2 Fig. V Fig. V Fig. II Fig. II Fig. II Type SMSI 5 AC O Cat. No. 8026930000 Type SMSI 5 AC Cat. No. 1112060000 Analogue Signal Processing Cat. No. 1112160000 201 Current Monitoring * For AC/DC * Adjustable switching threshold * Relay output Ordering data Technical data Measurement circuit voltage Max. permissible current in measurement circuit Rated consumption ~ (VA) Voltage drop at input Adjustable switching threshold Hysteresis between turn-on and turn-off point Activation time tA Reaction time tR Recovery Output voltage Max. continuous output current Auxiliary voltage Rated consumption auxiliary voltage Max. switching current Contact Contact material Storage temperature Ambient temperature -, assembled without spacing on TS -, assembled with 20 mm spacing on TS Coordination of insulation to DIN VDE 0160,Draft 11/94 Overvoltage category, input, output Overvoltage category, input1-input2, Output1-output 2, input-output Contamination class Dimensions and connection data see page 307 202 SMSI DC R SMSI AC R With adjustable switching threshold With adjustable switching threshold up to 250 mA up to 250 mA Type Cat. No. SMSI 0.25 DC R 1156660000 Type Cat. No. SMSI 0.25 AC R 1159960000 10 V...250 Vdc 350 mA 750 mVA (l = 250 mA) 3 V (I = 250 mA) 40 mA...250 mA- 2% (250 mA) 107 switching operations 0.5...5 s Coordination of insulation to VDE DIN 0160, draft11/94 Rated voltage Rated surge voltage Overvoltage category Contamination class 300 V 4 kV III 2 Clearance and creepage distance EMC 3 mm EN 50 081-1/50 082-2 Accessories and dimensions see page 307 Fig. VI 206 Namur Switch Amplifiers EGV-Namur EGV-Inverter Block diagram Ordering data Type EGV Namur Cat. No. 1120360000 Type EGV Inverter Cat. No. 1122460000 Description Switching amplifier for 2-wire Namur initiators with relay output. This module inverts the switching function of electronic outputs. Enables the use of economic Namur initiators with short design lengths. This is particularly valid for areas where initiators are subjected to heavy mechanical stresses, and often need to be replaced. A potential-free NO contact is available on the output side for switching larger ratings (2000 VA). The Namur initiator can be directly connected to the module. LED function indicators indicate switching statuses. A PNP output is changed into an NPN output with the load connected unilaterally against the positive potential (the negative potential is switched through). An NPN output is changed into a PNP output with the load connected unilaterally to the frame potential (the positive potential is switched through). The module reduces the inventory of sensors and electronic switches with PNP/NPN outputs to a single type. Technical data Input voltage Initiator type/initiator voltage Output voltage, -current Continuous current Max. switching capacity (resistive load) Contact Contact material Mechanical service life Ambient temperature 24 Vdc 10% approx. 8 Vdc 250 Vac/dc 3A 2000 VA 1 NO AgNi 0.15 gold-flashed > 107 switching operations 40 C mounted 24 Vdc 10% (closed circuit current < 10 mA) 24 Vdc 10% (switching threshold approx. 15 V) Coordination of insulation to VDE DIN 0160, draft11/94 Rated voltage Rated surge voltage Overvoltage category Contamination class Clearance and creepage distance EMC 300 V 4 kV III 2 3 mm EN 50 081, EN 50 082, EN50 011 EN 50 081, EN 50 082, EN50 011 Accessories and dimensions see page 307 Fig. VI Fig. V Analogue Signal Processing 200 mA 207 Set Point Generator EMA / SW 24 * Set point generator * switchable -10.5 V/+10.5 V Set point 1 or set point 2 can be switched to the module's output as required. The changeover is performed safely separated via the control input E1. The output voltage values (0...10.5 V) can be set using the spindle operated potentiometers SW1 and SW2. The control input E" determines the polarity safely separated (-10.5 V ... 0 V ... +10 V). Control input E1: 0 V = set point 1, 24 V = set point 2, Control input E2: 0 V = positive set point, 24 V = negative set point Ordering data electronic changeover switch Type Cat. No. EMA/SW 1172660000 Technical data Input signal/measurement range 0=0 V, 1=+24 V Control voltage Max. input current 24 V20 % 7 mA at 24 V Display Setting each control input: red LED via trimming potentiometer 25 rotations nom. Output signal Output Output current Load resistance adjustable from -10.5 V...+10.5 V Voltage output selection by E1/E2 max. 25 mA at Urated=24 V- min. 400 at Urated=24 V Slew-Rate 0.168 V/s Supply voltage UB Residual ripple Reaction time 24 V- 20 %, 30 mA (RL= ) 30 mV/106 kHz (at Umax) rising 50 s decreasing 80 s Isolation voltage, voltage strength Input/output/supply Input-Output/TS Storage temperature Operating temperature Insulation coordination according to EN 50 178 Overvoltage category Contamination class Accessories, dimensions and connection data see page 307 208 1 kV4 kVeff -20 C...+70 C 0 C...+50 C III 2 Fig. V 209 Analogue Signal Processing 8-Bit Analogue/Digital Converters RS/U-D8 Hold function (H): Enable function (E): The converter can, for example, by means of the hold function (H) be matched to the cycle time of a PLC. Holding and release of the conversion. The Hold input (H) is internally connected to 0 V via a resistor. In order to store the last signal, the Hold input (H) must be supplied with 24 V. The Enable circuit (E) allows several converters, e.g. on an input card of a PLC, to be switched on. The Enable input (E) is connected internally to 0 V via a resistor. In order to make the connection to the PLC, one converter must be disconnected. The other converters are supplied with 24 V (at least 12 V). This causes the converters at the output to be highly resistive. Functions table (example) Block diagram Terminal PIN MSB E8 E7 0 0 0 0 0 0 0 0 1 1 1 1 1 1 E6 0 0 0 0 E5 0 0 0 0 E4 0 0 0 0 E3 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 Ordering data RS/I-D 8 Block diagram Digital volue/ Analog digital E2 0 0 1 1 0 1 1 voltage LSB value Analogue voltage E1 0V 0 1 0 1 1 0 +10 V 1 Type RS/U-D 8 Cat. No. 1122361001 Type RS/U-D 8 Cat. No. 1160361001 Type RS/I-D 8 Cat. No. 1160561001 Type RS/I-D 8 Cat. No. 1168561001 Technical data Input signal -10 V...+10 V 0...10 V 0...20 mA 4...20 mA Max. input voltage Max. input current Input resistance Max. limit frequency Resolution 55 A 200 k 5 kHz at Full-Scale (Sinus)1) 78 mV c 1 LSB 25 A 400 k 5 kHz at Full-Scale (Sinus)1) 39 mV c 1 LSB 3.5 V 25 mA 51 5 kHz at Full-Scale (Sinus)1) 78 A c 1 LSB 3.5 V 25 mA 51 5 kHz at Full-Scale (Sinus)1) 62.5 A c 1 LSB 8 Bit (1 Bit prefix) 25 mA (as source) approx. 17 V c H, 0 V c L MSB: H c positive, L c negative 1 LSB 4 s 24 V-, 20 %, 35 mA (plus output current) 8 Bit 25 mA (as source) approx. 17 V c H, 0 V c L 8 Bit 25 mA (as source) approx. 17 V c H, 0 V c L 8 Bit 25 mA (as source) approx. 17 V c H, 0 V c L 1 LSB 4 s 24 V-, 20 %, 35 mA (plus output current) 1 LSB 4 s 24 V-, 20 %, 35 mA (plus output current) 1 LSB 4 s 24 V-, 20 %, 35 mA (plus output current) Terminal 1 Terminal 1 Terminal 1 Terminal 1 Output signal Output current Output level Prefix Transmission error Conversion time Supply Connection arrangement Storage temperature Operating temperature ... ... ... LSB Terminal 8 MSB Terminal 9 Enable2) Terminal 10 Hold Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion Terminal 8 MSB Terminal 9 Enable2) Terminal 10 Hold Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion Terminal 8 MSB Terminal 9 Enable2) Terminal 10 Hold Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion Terminal 8 MSB Terminal 9 Enable2) Terminal 10 Hold Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C 1) 2) EMC EN 50 081-1/50 082-2 210 LSB ... ... LSB ... ... ... LSB 1 LSB-Accuracy Enable: 24 V = tristate 0 V = free conversion 8-Bit Digital/Analogue Converters RS/D 8-U RS/D 8-I Block diagram Block diagram Ordering data Type RS/D 8-U Pin assignment Cat. No. 1123361001 Type RS/D 8-U Cat. No. 1160761001 Type RS/D 8-I Cat. No. 1165861001 Type RS/D 8-I Cat. No. 1169261001 Technical data Input signal 8 Bit (1 Bit prefix) 8 Bit 8 Bit 8 Bit Max. input voltage Max. input current Input resistance Prefix Resolution 5...24 V (typ. 24 V) 2.5 mA 50 k per input MSB: H c positive, L c negative 78 mV c 1 LSB 5...24 V (typ. 24 V) 2.5 mA 50 k per input 5...24 V (typ., max. 30 V) c H 5...24 V (type., max. 30 V) c H 50 k per input 50 k per input 39 mV c 1 LSB 78 A c 1 LSB 62.5 A c 1 LSB Output signal Output current Offset Load resistance Transmission error Conversion time Supply -10 V...+10 V 10 mA max. current 20 mV 1 k 1 LSB 30 s 24 V-, 20 %, 25 mA (plus output current) 0...10 V 10 mA 20 mV 1 k 1 LSB 30 s 24 V-, 20 %, 25 mA (plus output current) 0...20 mA 0...20 mA (as source) max. 0.08 mA 500 1 LSB 30 s 24 V-, 20 %, 25 mA (plus output current) 4...20 mA 4...20 mA (as source) 4 mA 500 1 LSB 30 s 24 V-, 20 %, 25 mA (plus output current) Terminal 1 Terminal 1 Terminal 1 Terminal 1 Storage temperature Operating temperature ... LSB ... LSB ... ... LSB ... ... ... LSB ... Connection arrangement Terminal 8 MSB Terminal 9 Hold Terminal 10 0 V Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion Terminal 8 MSB Terminal 9 Hold Terminal 10 0 V Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion Terminal 8 MSB Terminal 9 Hold Terminal 10 0V Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion Terminal 8 MSB Terminal 9 Hold Terminal 10 0 V Hold function: High c +24 V c storage of last converted value Low c 0 V c free conversion -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C EMC EN 50 081-1/50 082-2 211 Analogue Signal Processing Pin assignment 12-Bit Analogue/Digital Converters Hold function (H): The converter can, for example, by means of the hold function (H) be matched to the cycle time of a PLC. Holding and release of the conversion. The Hold input (H) is internally connected to 0 V via a resistor. In order to store the last signal, the hold input (H) must be supplied with 24 V. Functions table (example) Terminal PIN 8 0 0 0 0 7 0 0 0 0 6 0 0 0 0 5 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Ordering data Technical data Input signal/measurement range LSB 2 1 0 0 0 1 1 0 1 1 - - 1 1 0 1 1 1 1 0 1 1 1 1 4 0 0 0 0 3 0 0 0 0 Type RS/U-D 12 Cat. No. 1168261001 Type RS/U-D 12 -10...+10 V 0...10 V Max. input voltage Max. input current Input resistance Prefix Resolution 15 V 15 V 100 k MSB: H c positive, L c negative 4.88 mV c 1 LSB Output signal Output current Output level Load resistance Transmission error Conversion time Temperature coefficient Supply Max. power loss Connection arrangement EMC EN 50 081-1/50 082-2 212 Type RS/I-D 12 Cat. No. 1168461001 Type RS/I-D 12 Cat. No. 1169161001 100 k 30 mA 500 30 mA 500 2.44 mV c 1 LSB 4.9 A c 1 LSB 4 A c 1 LSB 12 Bit (1 Bit prefix) 25 mA (as source) 24 V c H, 0 V c L 12 Bit 25 mA (as source) 24 V c H, 0 V c L 12 Bit 25 mA (as source) 24 V c H, 0 V c L 12 Bit 25 mA (as source) 24 V c H, 0 V c L 1 LSB 50 s 1 LSB * 24 V-, 20 % 4W Terminal 1 LSB 1 LSB 50 s 1 LSB * 24 V-, 20 % 4W Terminal 1 LSB 1 LSB 50 s 1 LSB * 24 V-, 20 % 4W Terminal 1 LSB 1 LSB 50 s 1 LSB * 24 V-, 20 % 4W Terminal 1 LSB ... 4...20 mA ... 0...20 mA ... Storage temperature Operating temperature Cat. No. 1168361001 ... 9 0 0 0 0 ... 10 0 0 0 0 ... 20 mA MSB 12 11 0 0 0 0 0 0 0 0 - - 1 1 1 1 1 1 ... Digital volue/ digital value 4 mA Block diagram ... Analog current Analog current Block diagram Terminal 12 MSB Hold function: High c +24 V c storage of digital signal Low c 0 V c enabling the conversion cycle Terminal 12 MSB Hold function: High c +24 V c storage of digital signal Low c 0 V c enabling the conversion cycle Terminal 12 MSB Hold function: High c +24 V c storage of digital signal Low c 0 V c enabling the conversion cycle Terminal 12 MSB Hold function: High c +24 V c storage of digital signal Low c 0 V c enabling the conversion cycle -40 C...+80 C 0 C...+50 C -40 C...+80 C 0 C...+50 C -40 C...+80 C 0 C...+50 C -40 C...+80 C 0 C...+50 C 12-Bit Digital/Analogue Converters Ordering data Type RS/D 12-U Block diagram Cat. No. 1160861001 Type RS/D 12-U Cat. No. 1166161001 Type RS/D 12-I Cat. No. 1166061001 Type RS/D 12-I Cat. No. 1165961001 Technical data Input signal/measurement range 12 Bit (1 Bit as prefix) 12 Bit 12 Bit 12 Bit Max. input voltage Input current, Inom Input resistance Prefix Resolution 24 V-, 20 % 4.2 mA 5.7 k MSB: H c positive, L c negative 4.88 mV c 1 LSB 24 V-, 20 % 4.2 mA 5.7 k 24 V-, 20 % 4.2 mA 5.7 k 24 V-, 20 % 4.2 mA 5.7 k 2.44 mV c 1 LSB 4.9 A c 1 LSB 4 A c 1 LSB Output signal Output current Output level Load resistance Transmission error Conversion time Temperature coefficient Supply Max. power loss Connection arrangement -10 V...+10 V 10 mA 0 V...10 V 10 mA 0...20 mA 0...20 mA (as source) 4...20 mA 4...20 mA (as source) 1 k 1 LSB 4 s 100 ppm from FSR/C 24 V-, 20 %, 40 mA 1 k 1 LSB 4 s 100 ppm from FSR/C 24 V-, 20 %, 40 mA 500 1 LSB 4 s 100 ppm from FSR/C 24 V-, 20 %, 60 mA 500 1 LSB 4 s 100 ppm from FSR/C 24 V-, 20 %, 60 mA Terminal 1 Terminal 1 Terminal 1 Terminal 1 Storage temperature Operating temperature ... LSB ... ... LSB ... ... LSB ... ... ... LSB Analogue Signal Processing Block diagram Terminal 12 MSB Hold function: High c +24 V c storage of analogue signal Low c 0 V c enabling the conversion cycle Terminal 12 MSB Hold function: High c +24 V c storage of analogue signal Low c 0 V c enabling the conversion cycle Terminal 12 MSB Hold function: High c +24 V c storage of analogue signal Low c 0 V c enabling the conversion cycle Terminal 12 MSB Hold function: High c +24 V c storage of analogue signal Low c 0 V c enabling the conversion cycle -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C -40 C...+85 C 0 C...+50 C EMC EN 50 081-1/50 082-2 213