SENSOR PRODUCTS Precision Pressure Transducer - Explosion-Proof H APPLICATIONS Process Control Chemical Refineries Oil and Gas Paper and Pulp PPTE oneywell's PPTE offers an explosion-proof pressure transducer where protection in hazardous locations is critical. It combines proven silicon sensor technology with microprocessor-based signal conditioning to provide an extremely smart pressure transducer. Designed with a hermetically sealed, stainless steel construction, the PPTE operates in severe vibration, thermal and mechanical shock environments. The PPTE has many software features that support a wide range of applications. Class I, Groups B,C,D Class II, Groups E,F,G Class III Temp. T6 Max Ambient = 70C Type 4X Q u a l i f i e d ISO 9001 FEATURES AND BENEFITS High Accuracy: 0.10% FS typical accuracy from -40 to 85C Simplifies system design--no additional signal compensation needed to gain the benefits of a very accurate sensor. Smart, Digital Sensing & Control Efficient data acquisition--connect up to 89 units on a multidrop bus using built-in RS485 capability. Easily interfaces directly to a PC via communication ports. Closes the loop--smart PPT makes control decisions. Versatile and Configurable Works with existing and new systems--all units have 0-5V analog and either RS232 or RS485 digital outputs. Isolation diaphragms handle most media--harsh gases or liquids. Operates in severe vibration, thermal and mechanical shock environments. Optimizes output--user-configurable pressure units, sampling, update rate. Flags problems--internal diagnostics set flags, provide alarms. FEATURES AND BENEFITS FEATURES AND BENEFITS User-Selectable Software Features Baud Rate, Parity Setting Continuous Broadcast ASCII or Binary Output Temperature Output (C or F) Deadband, Sensitivity Tare Value Configurable Analog Output And more... PPTE SENSOR PRODUCTS SPECIFICATIONS CASE OUTLINE (1) Performance Specifications Accuracy: (from -40 to 85C) Digital: 0.10% FS Typ., 0.20% FS Max. Analog: 0.12% FS Typ., 0.24% FS Max. Temperature: 1C (at sensing element) Temperature Range: Operating: -40 to 85C (-40 to 185F) Storage: -55 to 90C (-67 to 194F) Sample Rate: 8.33ms to 51.2min Update Rate: 8.33ms to 12s Resolution: Digital: Up to 10 PPM Analog: 1.22mV steps (12 bits) Response Delay: (1000/update rate) + 1ms, maximum 17ms Mechanical Specifications Pressure Ranges and Type: See ordering information. Media Compatibility: Suitable for media compatible with 316 stainless steel. (Hastelloy diaphragm option) Weight: 22 oz. (624 gm) NPT w/pigtail style Electrical Specifications Power Requirements: Supply Voltage: 6.0 to 30 VDC Operating Current: 19-27mA Standby Current: 11mA Analog Output: 0-5 V (User adjustable) Environmental Features(2)(3) Overpressure: 3x FS, maximum 6000 psi Burst Pressure: 3x FS, maximum 8500psi Mechanical Shock: 1500g, 0.5ms half sine Temp Shock: 24 1-hr cycles, -40 to 85C Vibration: 0.5in or 20G's, 20 Hz - 2K Hz (1) Accuracy is the sum of worst case linearity, repeatability, hysteresis, thermal effects and calibration errors from -40 to 85C. Typical is the average of absolute value of errors at all pressures and temperatures. (2) Exposure to overpressure will not permanently affect calibration or accuracy of unit. Burst pressure is the sum of the measured pressure plus the static pressure and exceeding it may result in media escape. Mechanical Shock tested per MIL-STD-883D, M2002.3, Cond B. Vibration tested per MIL-STD-883D, M2007.2, Cond A. (3) CE Mark tested per EN50081-2, EN50082-2. ORDERING INFORMATION Example: PPTE1000AP2VDC PPTE Precision Pressure Transducer - Explosion-Proof FULL SCALE PRESSURE RANGE Absolute Gauge 0010 n/a 10 PSI 0015 15 PSI n/a 0020 20 PSI 20 PSI 0040 40 PSI 40 PSI 0100 100 PSI 100 PSI 0300 300 PSI 300 PSI 0500 500 PSI 500 PSI 1000 1000 PSI 1000 PSI 1500 1500 PSI 1500 PSI 3000 3000 PSI 3000 PSI Type P1 Pressure P2 Pressure 0 (vacuum) to FS N/A A Absolute G Gauge Reference to FS Reference P1 PRESSURE CONNECTION P 1/4 - 18 NPT (internal) OUTPUTS 2V RS-232 digital, 0-5V analog 5V RS-485 digital, 0-5V analog ELECTRICAL CONFIGURATION AND CONNECTION D 1/2 - 14 NPT external w/ 4ft pigtail cable EXPLOSION-PROOF CERTIFICATION C CSA, Canadian Standards Association Class I, Groups B,C,D; Class II, Groups E,F,G; Class III F FM, Factory Mutual Class I, Groups B,C,D; Class II, Groups E,F,G; Class III OPTIONS D Hastelloy Diaphragm PPTE 1000 A P 2V D C - D Honeywell reserves the right to make changes to any products or technology herein to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. Covered by one or more of the following US Patents: 4,918,992; 4,788,521; and 5,948,988. Solid State Electronics Center 12001 State Highway 55 Plymouth, MN 55441 1-800-323-8295 E-Mail: ssec.customer.service@honeywell.com Web Site: www.ssec.honeywell.com 900133 9/00