UHP-350 350W Slim Type with PFC Switching Power Supply series Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 GB4943 UL60950-1 EN60950-1 EN60335-1 IEC60950-1 -~ Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipments or apparatus Household appliances LED display application ; R File Name:UHP-350-SPEC 2019-05-15 350W Slim Type with PFC Switching Power Supply UHP-350 series SPECIFICATION UHP-350 -3.3 UHP-350 -4.2 UHP-350 MODEL INPUT FUNCTION -15 UHP-350 -24 UHP-350 -36 UHP-350 DC VOLTAGE 3.3V 4.2V 5V 12V 15V 24V 36V 48V 60A 60A 60A 29.2A 23.4A 14.6A 9.75A 7.3A RATED POWER(convection) 198W 252W 300W 350.4W 351W 350.4W 351W 350.4W 240mVp-p 240mVp-p -48 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 3.2~3.5V 3.6~4.4V 4.5~5.5V 11.4~12.6V 14.3~15.8V 22.8~25.2V 34.2~37.8V 45.6~50.4V VOLTAGE TOLERANCE Note.2 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.3% 0.3% 0.3% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 94% 94% 94% 39.6 ~46.8V 52.8 ~ 62.4V Note.3 SETUP, RISE TIME 2000ms, 80ms/230VAC HOLD UP TIME (Typ.) 10ms/230VAC 10ms/115VAC VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC Note.4 3000ms, 80ms/115VAC at full load FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF0.94/230VAC PF0.98/115VAC at full load EFFICIENCY (Typ.) 88.5% 89% AC CURRENT (Typ.) 4A/115VAC Cold start 30A/115VAC LEAKAGE CURRENT <0.75mA / 240VAC OVER VOLTAGE 91% 90% INRUSH CURRENT (Typ.) OVERLOAD PROTECTION -12 UHP-350 RATED CURRENT RIPPLE & NOISE (max.) OUTPUT -5 UHP-350 92% 2A/230VAC 60A/230VAC 110~140% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.6V 4.62 ~ 5.46V 5.75 ~ 6.75V 13.2 ~ 15.6V 16.5 ~ 19.5V 26.4 ~ 31.2V Protection type :Shut down O/P voltage,re-power on to recover OVER TEMPERATURE Protection type :Shut down O/P voltage, recovers automatically after temperature goes down DC OK SIGNAL(Optional) Contact rating(max.):15Vdc/10mA resistive load REDUNDANT(Optional) For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system WORKING TEMP. -30 ~ +70(Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1,TUV EN60950-1,EN60335-1,CCC GB4943,BSMI CNS14336-1,EAC TP TC 004 approved,Design refer to EN61558-1,-2-16 WITHSTAND VOLTAGE SAFETY & EMC ISOLATION RESISTANCE (Note.6) I/P-FG:2KVAC O/P-FG:1.25KVAC EMC EMISSION Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020 MTBF 285 K hrs min. OTHERS DIMENSION PACKING NOTE I/P-O/P:3.75KVAC I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25/ 70%RH MIL-HDBK-217F (25) 220*62*31mm (L*W*H) 0.68 kg;16 pcs/11.88 kg/0.63CUFT File Name:UHP-350-SPEC 2019-05-15 UHP-350 350W Slim Type with PFC Switching Power Supply series Block Diagram PFC fosc:65KHz PWM fosc:70KHz~90KHz EMI FILTER & RECTIFIER I/P POWER SWITCHING PFC CIRCUIT RECTIFIERS & FILTER FG O.T.P. +V -V DETECTION CIRCUIT O.L.P. CONTROL O.V.P. DC OK Function Redundant Function Derating Curve 230Vac for 12V~48V 100 100 RATED CURRENT (%) RATED CURRENT (%) 230Vac for 3.3V~5V 80 60 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 80 70 60 110Vac for all model 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE() RATED CURRENT (%) 100 80 60 40 20 -30 0 10 20 30 40 50 60 70 80 90 (HORIZONTAL) Tcase () File Name:UHP-350-SPEC 2019-05-15 350W Slim Type with PFC Switching Power Supply UHP-350 series STATIC CHARACTERISTIC 100 90 LOAD (%) 80 70 60 50 40 90 110 100 120 140 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz Function Manual 1.DC_OK Signal DC_OK is a collector shorted signal. It is used by an optocoupler in the power supply which indicates the output status of the power supply as exhibited below. DC OK +V 1K +V PSU turns on DC ok Optocoupler C-E Pin Open PSU turns off DC fail Optocoupler Rating(max.) 15Vdc/10mA resistive load E C Optocoupler C-E Pin Conduction GND COM PSU 2.Redundant function (1) UHP-350R is built-in redundant function and can be connected 2 units in parallel . (2) When in parallel operation the maximum load should not be greater than the rated power of any PSU. +V PSU -V +V LOAD -V +V PSU -V File Name:UHP-350-SPEC 2019-05-15 UHP-350 350W Slim Type with PFC Switching Power Supply Mechanical Specification CASE NO.:232C series Unit:mm 220 214 7.8 3 1 10.9 46.4 7.62 2 2 62 TB3 3 8.5 9.25 TB1 1 2 CN10 3 1 TB2 4 SVR 4-3.3 L=6 31 15.5 110 tc tc : Max. Case Temperature AC Input Terminal(TB1) pin NO. Assignment Pin No. 1 2 3 Assignment AC/L AC/N DC Output Terminal(TB2,TB3) pin NO. Assignment Terminal Max mounting torque (DEGSON) DG28C-B-03P 5Kgf-cm Pin No. 1,2 3,4 Assignment Terminal -V (MW) TB-HTP-200-40A +V Max mounting torque 8Kgf-cm DC OK Connector(CN10):JST B2B-PH-K-S or requivalent Pin No. 1 2 Assignment DC COM DC OK +V Mating Housing Terminal JSTPHR-2 JSTSPH-002T-P0.5S or requivalent or requivalent File Name:UHP-350-SPEC 2019-05-15 350W Slim Type with PFC Switching Power Supply UHP-350 series Installation 1.Operate with additional aluminum plate In order to meet the"Derating Curve"and the "Static Characteristics" ,UHP-350 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-350 series must be firmly mounted at the center of the aluminum plate. unit:mm 450 3 M3*4 450 File Name:UHP-350-SPEC 2019-05-15