FF 018 Filter Fan 14 - 69 cfm Very low noise Minimal mounting depth Functional design Time-saving installation Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channeling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localized heat pockets and protects the electronic components from overheating. The plastic used for the hood of this filter fan series is highly weather resistant, as well as impact and UV light resistant. Ventilating Weather and UV resistant | Technical Data Axial fan, ball bearing service life min. 50,000h at 77F (25C) and 65% RH aluminum fan body, plastic rotor Connection 2 wires w/ cage clamps, AWG 14 (2.5mm), length 4" (100mm) Housing (filter fan and exhaust filter) Plastic, UL 94V-0, light grey Hood (filter fan and exhaust filter) Plastic, UL 94V-0, light grey; weather and UV light resistant according to UL 746C (f1) Mounting frame with double-sided industrial adhesive for mounting to the outside of enclosure; certain operating circumstances may make the additional use of screws necessary; cut-out template included Filter media rating G4 acc. to DIN EN 779, filtering degree 94% Filter material synthetic fiber with progressive construction, temperature resistant to 212F, self-extinguishing class F1; moisture resistant to 100% RH, reusable - can be cleaned by washing or vacuuming Enclosure ventilation using a filter fan and exhaust filter Operating / Storage temperature +14 to +158F (-10 to +70C) / -40 to +158F (-40 to 70C) Protection class I (grounded) Protection type IP55 (according to VDE), UL Type 1 Note: Using fine filter mat F5 increases the protection to UL Type 12 but reduces the air flow Special features The self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet. Functional design of the intake and exhaust fan hoods very effectively prevents direct infiltration of falling water and dust. The advantage is that the filter mat does not rapidly become contaminated with dirt and therefore does not need to be exchanged as often. The air channeling makes the filter fan particularly quiet in operation. All filter fan models are also available with integrated airflow monitor. The direction of air flow can easily be switched by reversing the axial fan. 01800.0-00 230VAC, 50Hz1) 12 cfm (21m/h ) Air volume Power Average noise level with exhaust filter consumption (DIN EN ISO 4871) 9 cfm (16m/h) 13W 31dB (A) 1.8" (45mm) 3.8 x 3.8" 1.3 lbs. (0.6kg) 01800.0-01 120VAC, 60Hz 14 cfm (24m/h) 11 cfm (18m/h) 13W 31dB (A) 1.8" (45mm) 3.8 x 3.8" 1.3 lbs. (0.6kg) UL File No. E234324 01801.0-00 230VAC, 50Hz1) 32 cfm (55m/h) 25 cfm (42m/h) 15W 40dB (A) 2.3" (58mm) 4.9 x 4.9" 2.2 lbs. (1.0kg) UL File No. E234324, VDE 01801.0-01 120VAC, 60Hz Part No. 1) Operating voltage Air volume, free blowing Mounting depth Enclosure cut-out Weight (approx.) Approvals UL File No. E234324, VDE 37 cfm (63m/h) 28 cfm (48m/h) 15W 40dB (A) 2.3" (58mm) 4.9 x 4.9" 2.2 lbs. (1.0kg) UL File No. E234324 01802.0-00 230VAC, 50Hz1) 60 cfm (102m/h) 40 cfm (68m/h) 15W 39dB (A) 3.4" (86mm) 6.9 x 6.9" 2.9 lbs. (1.3kg) UL File No. E234324, VDE 01802.0-01 120VAC, 60Hz 46 cfm (78m/h) 15W 39dB (A) 3.4" (86mm) 6.9 x 6.9" 2.9 lbs. (1.3kg) UL File No. E234324 69 cfm (117m/h) air volume increases by 15% when operating 230VAC filter fans at 60Hz Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FF018/2-11/US EMC versions and other voltages are available upon request. FF 018 Filter Fan 14 - 69 cfm Time-saving assembly and maintenance STEGO's filter fans are easily installed by one person from outside the cabinet. 1.) Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, filings and grease. A template for the enclosure cut-out is included with the filter fan. Ventilating 2.) Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays permanently in the cabinet. 3.) Electrically connect the axial fan using the cage clamp connectors. Push the unit into the mounting frame. Affix using screws if necessary. 4.) Insert the filter mat in the hood. Clip on. Finished. Installation sketch To change the filter mat, simply remove the filter hood, insert the new mat and snap the hood back again. No tools are required. Maintenance of the fan can easily be performed without removing the mounting frame (2). Dimensional Drawing 8.2" 3.4" 8.9" 6.7" 4.9" 5.3" 2.0" 6.2" 6.9" 1.6" 2.3" 5.1" 3.8" 1.4" 1.8" Drilling template for mounting frame O1/8" (3mm) O1/8" (3mm) 7.4" (188 mm) 5.4" (137 mm) 4.3" (109 mm) 7.4" (188 mm) 5.4" (137 mm) 4.3" (109 mm) O1/8" (3mm) EF 118 Exhaust Filter Part No. 11800.0-00 11801.0-00 11802.0-00 Mounting depth 0.6" (16mm) 0.6" (16mm) 0.6" (16mm) Enclosure cut-out 3.8 x 3.8" 4.9 x 4.9" 6.9 x 6.9" Weight (approx.) 0.6 lbs. (0.3kg) 0.8 lbs. (0.4kg) 1.3 lbs. (0.6kg) Filter mat G4 acc. to DIN EN 779, filtering degree 94% G4 acc. to DIN EN 779, filtering degree 94% G4 acc. to DIN EN 779, filtering degree 94% Protection type IP55* IP55* IP55* Approvals UL File No. E234324 UL File No. E234324 UL File No. E234324 FF018/2-11/US *according to VDE FM 086 Filter Mats Filter mat G4 (1 packing unit = 3 pcs.) F5 (1 packing unit = 3 pcs.) 3.5 x 3.5" (89 x 89mm) Part No. 08600.0-00 Part No. 08603.0-00 4.6 x 4.6" (118 x 118mm) Part No. 08601.0-00 Part No. 08604.0-00 6.6 x 6.6" (168 x 168mm) Part No. 08602.0-00 Part No. 08605.0-00 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com