Ledex(R) Size 125 Pull Tubular Solenoids -- 1-1/4" Dia. x 2-1/4" Part Number: 174419-0 XX LINEAR Tubular All products are RoHS Compliant Coil AWG Number (from performance chart below) Performance Specifications Maximum Duty Cycle 100% 50% 25% 10% Maximum ON Time (sec) when pulsed continuously1 390 60 18 Maximum ON Time (sec) for single pulse2 510 160 45 Watts (@ 20C) 13 26 52 130 1500 2121 3000 4743 Ampere Turns (@ 20C) awg (0XX)3 23 24 25 26 27 28 29 30 31 32 33 1 2 3 4 Coil Data Resistance # (@20C) Turns4 3.52 6.04 8.47 14.10 22.50 36.10 55.10 88.10 147.00 214.00 354.00 780 1056 1176 1540 1970 2484 3060 3805 5044 5992 7744 VDC VDC VDC VDC (Nom) (Nom) (Nom) (Nom) 6.8 8.6 10.9 13.8 17.3 22.0 27.0 35.0 44.0 54.0 69.0 9.6 12.2 15.4 19.5 24.0 31.0 38.0 49.0 62.0 76.0 98.0 13.6 17.2 22.0 28.0 35.0 44.0 54.0 70.0 88.0 107.0 138.0 22.0 27.0 34.0 44.0 55.0 69.0 86.0 110.0 139.0 170.0 218.0 Dielectric Strength Recommended Minimum Heat Sink Coil Resistance Holding Force Weight Plunger Weight 1000 VRMS Maximum watts dissipated by solenoid are based on an unrestricted flow of air at 20C, with solenoid mounted on the equivalent of an aluminum plate measuring 5" square by 1/8" thick 5% tolerance 9 lbs (40.0 N) @ 20C 10.41 oz (295 g) 1.87 oz (53.2 g) How to Order Add the coil awg number (0XX) to the part number (for example: to order a 25% duty cycle unit rated at 35 VDC, specify 174419-027). Please see www.ledex.com for our list of stock products available through our North American distributors. Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature 20C) Other coil awg sizes available -- please consult factory Reference number of turns All specifications subject to change without notice. Ledex(R) Solenoids www.ledex.com 1.937.454.2345 Fax: 1.937.898.8624 Ledex(R) Size 125 Pull Tubular Solenoids -- 1-1/4" Dia. x 2-1/4" Typical Force @ 20C Typical Speed @ No Load, 20C 20.0 (89.0) 80 10% Duty Cycle 130W 25% Duty Cycle 52W 50% Duty Cycle 26W 100% Duty Cycle 13W 10.0 (44.50) 60 Time - ms Force - lbs (N) 15.0 (66.75) 10% Duty Cycle 130W 25% Duty Cycle 52W 50% Duty Cycle 26W 100% Duty Cycle 13W 40 5.0 (22.25) 20 0 0.10 (2.5) 0.20 (5.1) 0.30 (7.6) 0.40 (10.2) 0.50 (12.7) Stroke - in (mm) 0.60 (15.2) 0 0.70 (17.8) 0.20 0.40 0.60 0.80 1.00 (5.08) (10.16) (15.24) (20.32) (25.4) Stroke - in (mm) Force values for reference only. Inches (mm) Dimensions All solenoids are illustrated in energized state 0.058 (1.473) 0.656 (16.662) 1.656 (42.062) 1.312 max (33.325) 0.718 +- 0.015 (18.237 +- 0.381) 1.25 +- 0.015 (31.75 +- 0.381) 0.144 +- 0.002 (3.657 +- 0.051) 4 holes 0.020/0.030 Chamfer (0.51/0.76) x 45 5 0.187 (4.749) 0.500 +- 0.003 0.375 (12.7 +- 0.762) (9.525) 0.127 +- 0.002 0.156 0.312 +- 0.015 (3.226 +- 0.051) (3.962) (7.925 +- 0.381) dia 0.578 +- 0.015 (14.681 +- 0.381) 1.156 (29.362) Plunger stop 2.25 +- 0.031 (57.15 +- 0.787) 6.00 (152.4) min leads #22 AWG PVC Ledex(R) Solenoids www.ledex.com 1.937.454.2345 Fax: 1.937.898.8624