Click on Series name for product info on aimtec.com Series AMSRL-78-NZ Up to 7.5 Watt | DC-DC Switching Regulator FEATURES: * * * * * * * * * * * * Switching Regulator Low Noise Wide Input Non-Isolated Adjustable Output Voltage Thermal Shutdown SMD Package Efficiency Up To 96% Remote On/Off Short Circuit Protection High MTBF RoHS Compliant Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Efficiency Vin Max (%) Efficiency Vin Min (%) 4.5-28 6-28 14-28 17-28 3.3 5 12 15 500 500 500 500 75 81 90 92 90 94 95 96 AMSRL-783.3-NZ AMSRL-7805-NZ AMSRL-7812-NZ AMSRL-7815-NZ NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Start up time On/Off Control Quiescent Current Nominal Typical Maximum Units See Models table above 2 ON -open or 1.5V < Vc < 6V ; OFF -GND or 0V < VC < 1V , 2uA Vin = min to max at 0% load 10 ms mA Output Specifications Parameters Voltage accuracy Short Circuit protection Short circuit restart Thermal shutdown Dynamic load stability Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Voltage adjustment range (V adj) Conditions Typical At 100% load Internal IC Junction 10-100% load Vin=(LL-HL) at full load 10-100% load -40C to +85C ambient 20MHz Bandwidth 3.3 5 12 15 Maximum Capacitive Load Maximum 3 Continuous, hiccup mode Auto-Recovery 160 75 0.5 1 0.02 25 1.8-5.5 2.5-8.0 4.5-13.5 4.5-15.5 1000 Units % C mV % % o %/ C mV p-p VDC uF General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight www.aimtec.com F 051e R8.H Conditions Typical 100% load With derating above 71 C 1.4 Maximum Units 100 MHz o C o C o C 95 % RH -40 to +85 -55 to +125 Free Air Convection Plastic (UL94-V0) 2.3 Tel: +1 514 620 2722 1 of 4 g Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMSRL-78-NZ Up to 7.5 Watt | DC-DC Switching Regulator General Specifications (continued) Parameters Conditions Dimensions (L x W x H) MTBF Maximum Soldering Temperature Turn on Transient process time Off idle current Typical Maximum Units 0.60 x 0.47 x 0.29 Inches 15.24 x 11.2 x 7.25 mm > 2 000 000 hrs (MIL-HDBK-217F, Ground Benign, t=+25 oC) 1.5mm from case for 10 sec 300 50 30 o C us uA Pin Out Specifications Pin 1 5 6 7 9 10 Single +V input +V output V adj Ground Ground ON/OFF Dimensions & PCB Foot Print Side View 15.24 (0.60) 10.16 (0.40) Front View A 7.25 7.00 (0.29) (0.28) 7.25 (0.29) 5.08 (0.20) 0.25 (0.01) 10 9 7 6 Top View 10 9 A 2.54 (0.10) 7 1 11.20 8.30 (0.44) (0.33) 5.00 angle 1 www.aimtec.com F 051e R8.H 5 5 0.25 (0.01) 6 1.13 (0.44) Tel: +1 514 620 2722 2 of 4 1.80 (0.07) 0.60 1.80 (0.024) (0.07) 11.02 (0.434) 2.54 (0.10) 1.00 (0.04) Unit:mm[inch] General tolerances:0.25mm [ 0.010inch] Grid: 2.54 x 2.54mm Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMSRL-78-NZ Up to 7.5 Watt | DC-DC Switching Regulator Derating Free Air Convection 71 C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature C Application Circuit V Input 10uF 50V 5 1 V Output AMSRL-78XX-NZ 10 C1 7&9 ON/OFF 6 C5 470 pF Ground R1 C2 C3 100uF 20V R2 Ground Model Number C2 (uF) AMSRL-783.3-NZ AMSRL-7805-NZ AMSRL-7812-NZ AMSRL-7815-NZ 22 22 10 10 It is recommended that ceramic capacitors are used for C2 & C3. It is recommended to install C3 to improve performance. C1 & C2 are required and should be installed as close to the converter as possible www.aimtec.com F 051e R8.H Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMSRL-78-NZ Up to 7.5 Watt | DC-DC Switching Regulator Model Number Nominal Output (V) Vout Adjusted Up R2 (K) Vout Adjusted Down R1 (K) AMSRL-783.3-NZ 3.3 = 75.1 - (10 x Vout) Vout - 3.3 AMSRL-7805-NZ 5 = 90.72 - (10 x Vout) Vout - 5 = (61 x Vout) -90.72 5 - Vout AMSRL-7812-NZ 12 = 280.81 - (20 x Vout) Vout - 12 = (71 x Vout) -280.81 12 - Vout AMSRL-7815-NZ 15 = 269.37 - (15 x Vout) Vout - 15 = (66 x Vout) -269.37 15 - Vout = (61 x Vout) -75.1 3.3 - Vout If it is needed to adjust the output voltage higher or lower than the converter's nominal value use the equations in the table above to calculate appropriate resistor values, insuring that the voltage is within the adjustment range for the converter used. If no voltage adjustment is needed connect a 470pF ceramic capacitor from pin 6 to ground. Recommended Circuits Conducted and Radiated Emissions NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.H Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only