49
1
2
3
6
4
5
7
8
9
10
Label mounts with insert plates offer additional labelling options. Secured via the front
elements, both elements are simply bolted on from the rear of the flush mounting plate
using a lock nut.
The RMQ 16 control circuit devices range can also be inscribed. The button plates
as well as the lenses for the illuminated push buttons and the flat lenses for
indicator lights are inscribed by laser (see page 282 for Label Editor information)
Thus, even after years of use, the information they provide is still clear and
unambiguous. These control circuit devices can be fitted with LEDs instead of
filament bulbs. This means no more changing of bulbs, because LED service life equals
machine life. The high degree of protection, IP 65, of the front elements ensures safe
operation even in harsh environments. This makes RMQ16 ideally suitable for industrial
applications.
RMQ-Titan, RMQ 16, SL
System Overview RMQ16
1 Emergency-stop button
2 Base plate
3 Key switch
4 Contact element break (red)
5 Illuminated push button
6 Contact element make (green)
7 Selector switch
8 Indicator light
9 Push-button
10 Button plate/insert label
Side by side mounting enables well
ordered control panels on the smallest
possible space.”
Befehls-und Meldegeraete_RMQ.indd 49 25.11.2010 9:22:12 Uhr
50
Without
Q18D-11 Q25D-11
Q18D-10 Q25D-10
Q18D-20 Q25D-20
Q18D-19 Q25D-19
Q18D-SW Q25D-SW Q18DR-SW Q25DR-SW
Q18D-WS Q25D-WS Q18DR-WS Q25DR-WS
Q18D-GN Q25D-GN Q18DR-GN Q25DR-GN
Q18D-RT Q25D-RT Q18DR-RT Q25DR-RT
Q18D-GE Q25D-GE Q18DR-GE Q25DR-GE
Q18D-BL Q25D-BL Q18DR-BL Q25DR-BL
Q18D-X Q25D-X Q18DR-X Q25DR-X
Q18LT-WS/WB Q25LT-WS/WB Q18LTR-WS/WB Q25LTR-WS/WB
Q18LT-GN/WB Q25LT-GN/WB Q18LTR-GN/WB Q25LTR-GN/WB
Q18LT-RT/WB Q25LT-RT/WB Q18LTR-RT/WB Q25LTR-RT/WB
Q18LT-GE/WB Q25LT-GE/WB Q18LTR-GE/WB Q25LTR-GE/WB
Q18LT-BL/WB Q25LT-BL/WB Q18LTR-BL/WB Q25LTR-BL/WB
Push-button actuators
IP 65, NEMA 13
Button plates 18 x 18 mm
Spring-return 25 x 25 mm
Spring-return 18 x 18 mm
Spring-return 25 x 25 mm
Spring-return
Illuminated push-button actuators
IP 65, NEMA 13
with 24 V filament lamp
Button lens 18 x 18 mm
Spring-return 25 x 25 mm
Spring-return 18 x 18 mm
Spring-return 25 x 25 mm
Spring-return
Befehls-und Meldegeraete_RMQ.indd 50 25.11.2010 9:22:18 Uhr
51
RMQ-Titan, RMQ 16, SL
Q18S1 Q25S1 Q18S3 Q25S3
Q18S1R Q25S1R Q18S3R Q25S3R
Q18S1R-A1 Q25S1R-A1 Q18S3R-A1 Q25S3R-A1
Q18S3R-A2 Q25S3R-A2
Q18S3R-A3 Q25S3R-A3
Q18S3R-A4 Q25S3R-A4
Q18S3R-A5 Q25S3R-A5
Q18S3R-A6 Q25S3R-A6
Q18S3R-A7 Q25S3R-A7
Q18WK1 Q25WK1
Q18WK1R Q25WK1R
Q18WK3 Q25WK3
Q18WK3R Q25WK3R
Q18WK3R1 Q25WK3R1
Q18WK3R2 Q25WK3R2
Q18LF-WS/WB Q25LF-WS/WB Q18LH-WS/WB Q25LH-WS/WB
Q18LF-GN/WB Q25LF-GN/WB Q18LH-GN/WB Q25LH-GN/WB
Q18LF-RT/WB Q25LF-RT/WB Q18LH-RT/WB Q25LH-RT/WB
Q18LF-GE/WB Q25LF-GE/WB Q18LH-GE/WB Q25LH-GE/WB
Q18LF-BL/WB Q25LF-BL/WB Q18LH-BL/WB Q25LH-BL/WB
3 positions 3 positions
= Stay-put 45° = Spring-return 45° For further individuel locking = Stay-put 45° = Spring-return 45°
arragements please enquire
I,0,II = Key can be withdrawn in the positions indicated
0
0,I
0
0
I,0,II
0
I,0
0,II
I,0
0
0,II
0
0,II
0
0
I,0,II
0
I,0
0,II
I,0
0
0
0,I
0
Key-operated actuators
IP 65, NEMA 13
18 x 18 mm
2 positions 25 x 25 mm
2 positions 18 x 18 mm
3 positions 25 x 25 mm
3 positions
Selector switch actuators
IP 65, NEMA 13
18 x 18 mm
2 positions 25 x 25 mm
2 positions
OC5EN
Online catalogue Quicklink
to www.moeller.net
Indicator lights
IP 65, NEMA 13
with 24 V filament lamp
Lens 18 x 18 mm
Flush 25 x 25 mm
Flush 18 x 18 mm
Extended 25 x 25 mm
Extended
Befehls-und Meldegeraete_RMQ.indd 51 25.11.2010 9:22:23 Uhr
52
Contact elements
f = Positive opening safety function
to IEC / EN 60 947-5-1
N/O N/C
E10 E01
.3
.4
.1
.2
Q18LWK1-WS/WB Q25LWK1-WS/WB Q18LWK1-GN/WB Q25LWK1-GN/WB Q18LWK1-RT/WB Q25LWK1-RT/WB
Q18LWK1R-WS/WB Q25LWK1R-WS/WB Q18LWK1R-GN/WB Q25LWK1R-GN/WB Q18LWK1R-RT/WB Q25LWK1R-RT/WB
Q18LWK3-WS/WB Q25LWK3-WS/WB Q18LWK3-GN/WB Q25LWK3-GN/WB Q18LWK3-RT/WB Q25LWK3-RT/WB
Q18LWK3R-WS/WB Q25LWK3R-WS/WB Q18LWK3R-GN/WB Q25LWK3R-GN/WB Q18LWK3R-RT/WB Q25LWK3R-RT/WB
Q18LWK3R1-WS/WB Q25LWK3R1-WS/WB Q18LWK3R1-GN/WB Q25LWK3R1-GN/WB Q18LWK3R1-RT/WB Q25LWK3R1-RT/WB
Q18LWK3R2-WS/WB Q25LWK3R2-WS/WB Q18LWK3R2-GN/WB Q25LWK3R2-GN/WB Q18LWK3R2-RT/WB Q25LWK3R2-RT/WB
Q25PV Q25LPV
Q25PV-S Q25LPV-S
8 I 8 E 8
8 E 8-SW
Screw adapter
1 x 1.5 mm2
2 x 0.75 mm2
For N/O For N/C For lamp
sockets
SRA10 SRA01 SRAL
Blank Blank
SQ-GE SR-GE
f
3 positions 3 positions 3 positions 3 positions 3 positions 3 positions
Housing
IP 65
Locations Surface
mounting
enclosures
Flush
mounting
panels
Emergency-Stop labels
in four languages
SQT11
in four languages
SRT11
Emergency-Stop actuators
IP 65,
NEMA 13
Tamper proof
25 x 25 mm
Non-illuminated illuminated by means
of 24 V multiple LED
Illuminated selector switches
IP 65,
NEMA 13
with 24 V filament lamp = Stay-put 45° = Spring-return 45°
18 x 18 mm
2 positions 25 x 25 mm
2 positions 18 x 18 mm
2 positions 25 x 25 mm
2 positions 18 x 18 mm
2 positions 25 x 25 mm
2 positions
Befehls-und Meldegeraete_RMQ.indd 52 25.11.2010 9:22:33 Uhr
53
Q18BS Q25BS
Q25AS
Q25AGR
Q25AGE
Laser inscription
Labelling plates
See Industrial Switchgear
Main Catalogue
START
STOP
RMQ-Titan, RMQ 16, SL
01SQ25 Q25TS-01
02SQ25 Q25TS-02
05SQ25 Q25TGE-05
111SQ25 Q25TS-111
110SQ25 Q25TS-110
10SQ25 Q25TS-10
11SQ25 Q25TS-11
without Q25TS-X
See Industrial Switchgear
Main Catalogue
Additional
texts and
symbols
Blanking plug, IP 65
18 x 18 mm 25 x 38 mm
Additional labelling
Insert Label
plates mounts,
complete
10 x 22 mm 25 x 38 mm
Cover plate
IP 65
For surface mounting
enclosures and flush
mounting panels
25 x 38 mm
Lights
Socket Wedge Base W2x4,6d
Positive pole connected to X1
Filament lamps 6 V / 1 W 12 V / 1 W 24-28 V / 1 W
WBGL6 WBGL12 WBGL24
LEDs
(AC / DC) 6 V / 45 mA 12 V / 24 mA 18-30 V / 7-12.5 mA
WBLED-GN6
WBLED-RT6
WBLED-GE6
WBLED-GN12
WBLED-RT12
WBLED-GE12
LEDWB-W
LEDWB-G
LEDWB-R
LEDWB-Y
LEDWB-B
OC6EN
Online catalogue Quicklink
to www.moeller.net