GST90A series
















{
90W AC-DC Reliable Green Industrial Adaptor
ψψ











 










File Name:GST90A-SPEC 2020-10-20
(optional)
THOMAS SAMUEL
THOMAS SAMUEL
IS13252
K60950-1
TPTC004
UL62368-1 EN62368-1 J62368-1 AS/NZS60950-1
IEC62368-1MS IEC60950-1
R33100
RoHS GB4943.1
SPECIFICATION
GST90A series
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.7
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 8
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GST90A15-P1MGST90A12-P1M GST90A19-P1M GST90A24-P1M GST90A48-P1M
15V12V
GST90A15GST90A12
19V
GST90A19
24V
GST90A24
48V
GST90A48
150mVp-p120mVp-p 180mVp-p 200mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
89.5%
89% 90% 90% 91%
1.3A / 115VAC 0.6A / 230VAC
Cold start 35 / 115AC 70A / 230VAC
1mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
348.7K hrs min. MIL-HDBK-217F(25)
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH non-condensing
±0.03% / (0~40)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/0.9CUFT
CONNECTOR
PLUG
CABLE See page 4~5 ; Other type available by customer requested







 

For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
https://www.meanwell.com/serviceDisclaimer.aspx
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
6A6.67A 4.74A 3.75A 1.87A
0 ~ 6A0 ~ 6.67A 0 ~ 4.74A 0 ~ 3.75A
0 ~ 1.87A
90W80W 90W 90W 90W
Protection type : Shut down o/p voltage, re-power on to recover
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
See page 4~5 ; Other type available by customer requested
90W AC-DC Reliable Green Industrial Adaptor
UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 ,
BIS IS13252, KC K60950-1, approved EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
RF field susceptibility
EFT bursts
Surge susceptibility
Level 4, 15KV air; Level 4, 8KV contact
Conducted susceptibility
Magnetic field immunity
Voltage dips , interruption
Level 2, 3V/m
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
File Name:GST90A-SPEC 2020-10-20
Derating Curve Static Characteristics
Mechanical Specification
AMBIENT TEMPERATURE ()
LOAD (%)
0-30 2010 30 40
20
40
50
80
60
100
6050 70
INPUT VOLTAGE (VAC) 60Hz
90 10095 120110 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
(HORIZONTAL)
70±10mm
145
32
60
Power LED
Ul1185 14AWG 1000±50mm for 12 ~ 15V
UL1185 16AWG 1200±50mm for 19 ~ 48V
GST90A series
Case No. GS90A Unit:mm
90W AC-DC Reliable Green Industrial Adaptor
DC output plug
Standard plug: P1M
P1M
2.5
5.5
Pin Assignment
C"+"
-V not connected to AC FG
InsideOutside
AC Inlet
IEC320-C14
File Name:GST90A-SPEC 2020-10-20
11±0.5mm
GST90A series
90W AC-DC Reliable Green Industrial Adaptor
File Name:GST90A-SPEC 2020-10-20
P1JR
P1LR
P1MR
5.5
5.5
5.5
2.1
2.5
2.5
9.5
P1I
P1L
P1J
5.5
5.5
5.5
2.1
2.5
2.1
9.5
9.5
11.0
11.0
11.0
P1IR 5.5 2.1 9.5
DC plug changeable through:
(1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
(2) Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide :
Example quick adapter accessory:
Optional DC plug: (Available in customized cable or quick adapter)
P2I
P2J
P2L
P2M
5.5
5.5
5.5
5.5
2.1
2.1
2.5
2.5
P2IR
P2JR
P2LR
P2MR
5.5
5.5
5.5
5.5
2.1
2.1
2.5
2.5
5.53
5.53
5.53
5.53
2.03
2.54
2.03
2.54
12.06
12.06
9.52
9.52
Type No. ABC
OD ID L
Type No. ABC
OD ID L
Type No. ABC
OD ID L
Type No.
P3C
0.7 11.02.35
ABC
OD ID L
1.7 11.04.0
1.7 11.04.75
P3A
P3B
9.5
9.5
9.5
11.0
9.5
11.0
11.0
11.0
P2S(S761K)
P2K(761K)
P2C(S760K)
P2D(760K)
Tuning Fork Style
Barrel Style
Lock Style
Min. Pin Style
B
A
A
B
C
(Straight)
C
(Right-angled)
C
(Straight)
C
(Right-angled)
C
EIAJ equivalent
C
Floating Locking
SWITCHCRAFT original or equivalent
Quick Adapter
Accessory
Available
None
None
P4C 5.1 11.0
7.4 0.6
A
B
D
3.4 11.0
5.5
4.4 11.0
6.5
1.0
1.4
P4A
P4B
Type No. ABD
OD ID
Center Pin
C
L
Center Pin Style
C
EIAJ equivalent
B
A
A
B
(Current rating: 7.5A max.)
None
None
GST90A series
90W AC-DC Reliable Green Industrial Adaptor
File Name:GST90A-SPEC 2020-10-20
None
None
None
Installation Manual
R1B
25
3
1
4
Length of Land L1 by request
( ’s standard length, L: mm, L1: mm)
MW 25 5
(red)
(black)
by customer
2
1
L1
L
2
1
R7B
+Vo
-Vo
Type No.
Min. DIN 4 Pin with Lock (male)
Stripped and tinned leads
+Vo
-Vo
Pin Assignment
PIN No.Output
Pin Assignment
PIN No.Output
Type No.
1
2
3
4+Vo
-Vo
KYCON KPPX-4P equivalent
R6B
Type No. PIN No.Output
1
2
3
+Vo
-Vo
+Vo
Min. DIN 3 Pin with Lock (male)
KYCON KPPX-3P equivalent
Pin Assignment
R7BF
+Vo
-Vo
Type No.
KYCON KPJX-CM-4S equivalent
Pin Assignment
PIN No.Output
1
2
3
4+Vo
-Vo
Min. DIN 4 Pin with Lock (female)
None
-Vo
-Vo
Type No. Pin Assignment
PIN No.Output
1
2
3
4-Vo
+Vo
DIN 5 Pin (male)
5+Vo
Quick Adapter
Accessory
1
2
4
3
2
1
3
2
1 4
3
Please refer to : http://www.meanwell.com/manual.html
(Current rating: 7.5A max.)
Available