PMK130 series
130 Watt Open Frame and U-Channel Power Supplies with PFC
INPUT SPECIFICATIONS
Input Voltage / Frequency Range 90-264VAC / 47-63 Hz
Inrush Current, typ: 60A @ 230VAC Input *
Input Current 2.3~0.8A (90-264VAC)
Power Factor (cold start) PF > 0.96 @ 230VAC
Leakage Current <0.3mA @ 264VAC, 50Hz
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Maximum Output Power 130 Watts
Preset Accuracy (Note 6) 1%
Line Regulation (Note 5) 0.5% nom / 1% max
Load Regulation (20% to FL) 0.5% nom / 1% max
Ripple/Noise (Notes 1,2,7) See Selection Chart
Turn On <4S, typ.
Hold Up Time 20mS, typ.
Rise Time 30mS, typ.
Short Circuit Protection Auto recovery *
Over Voltage Protection 130% max., Auto recovery *
Over Current Protection 150% max., Auto recovery *
Transient Response 10mS
Over Shoot/Under Shoot <10% of Nominal O/P VDC
GENERAL SPECIFICATIONS
Safety UL/cUL: UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
UL-EU: EN60950-1 2nd ed.
CE: EN60601-1-2
CB: IEC60950-1 2nd ed.
Isolation (Note 3) 4242VDC I/P - O/P *
2828 VDC I/P - GND *
707VDC O/P - GND *
Insulation Resistance ≥ 20MΩ (500VDC, 1S I/P-O/P)
EMI CISPR EN55011 class B
Efciency See Selection Chart
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Note 4) -10°C to +70°C (See Derate Curve)
Storage Temperature -25°C to +85°C
Relative Humidity 10 to +90%, non-cond *
EMS Harmonics: IEC61000-3-2 Class A
Fluctuations: IEC61000-3-3
ESD: IEC61000-4-2, 6KV Contact, 8KV Air
RS: IEC61000-4-3 FR: 80MHz-2.5GHz
Field Strength: 3V/M
EFT: IEC61000-4-4 2KV on AC Line
Surge: IEC61000-4-5 1KV (L-L);
2KV (L, N-PE)
CS: IEC61000-4-6 3V (EMF)
Dips: IEC61000-4-11 95% 250CY,
70% 25CY, 40% 5CY, 5% 0.5CY
MTBF 197,000 Hrs min. MIL-HDBK-217F
Vibration 4G Pk, 50~500Hz, 3 Axes, 30 min*
Drop Test Test Height 70cm *
PHYSICAL SPECIFICATIONS
Size Open Frame: 76.2 x 127 x 35.5mm (3” x 5” x 1.4”)
U-Channel: 127 x 80.4 x 38mm
(5” x 3.17” x 1.50”)
Weight Open Frame: 10.25 oz (291g)
U-Channel: 13.38 oz (380g)
NOTES:
1. All measurements should be made directly at the terminals of the
power supply.
2. Ripple and Noise depend upon output voltage a specied per
particular model.
3. Isolation for up to 1min duration.
4. Specied for free-air convection cooling.
5. Line regulation measured from 90 - 264VAC/100VAC minimum
required for full load start.
6. Preset accuracy measured at nominal load, 120VAC input.
7. O/P noise measured directly at pins/terminals @ nominal load, 0uF by
pass and 47uF electrolytic, pk-pk@ 20MHz bandwidth.
Special EMC Notice: The end application shall provide an earth ground
connection for conducted & radiated emission performance. Astrodyne is
not liable for the end application without extra earth connection to
PMK130S Open Frame Power Supply.